Katie Jo Stauffer

Katie Jo Stauffer

Auto-generated profile, based on publicly available information

Katie Jo Stauffer

Division of Pediatric Cardiology, Department of Pediatrics Stanford University Medical Center Palo Alto CA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2022 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
Elif Seda Selamet TierneyElif Seda Selamet Tierney
Elif Seda Selamet Tierney
SCSukyung Chung
Sukyung Chung
KSKatie Jo Stauffer
Katie Jo Stauffer
JBJerrid Brabender
Jerrid Brabender
RCRonnie Thomad CollinsII
Ronnie Thomad CollinsII
Mitra EsfandiareiMitra Esfandiarei
Mitra Esfandiarei
Background: Stiffer aortas are associated with a faster rate of aortic root (AoR) dilation and higher risk of aortic dissection in patients with Marfan syndrome. We have previously shown that mild aerobic exercise reduces aortic stiffness and rate of AoR dilation in a Marfan mouse model. In this study, we investigated if these results could be translated to pediatric patients with Marfan syndrome. Methods and Results: We enrolled 24 patients with Marfan syndrome aged 8 to 19 years to participate in a 6‐month physical activity intervention, excluding those with ventricular dysfunction or prior history of aortic surgery. We instructed patients to take 10 000 steps per day, tracked by an activity tracker. At baseline and 6 months, we measured AoR dimension, arterial stiffness, endothelial function, physical activity indices, inflammatory biomarkers, and coping scores. Controls consisted of 15 age‐matched patients with Marfan syndrome. Twenty‐four patients with Marfan syndrome (median age, 14.4 years [interquartile range {IQR}, 12.2–16.8], 14 male patients) were enrolled. Baseline assessment demonstrated that the majority of these patients were sedentary and had abnormal arterial health. Twenty‐two patients completed the intervention and took an average of 7709±2177 steps per day (median, 7627 [IQR, 6344–9671]). Patients wore their Garmin trackers at a median of 92.8% (IQR, 84%–97%) of their intervention days. AoR Z score in the intervention group had a significantly lower rate of change per year compared with the controls (rate of change, −0.24 versus +0.008; P =0.01). Conclusions: In this clinical intervention in pediatric patients with Marfan syndrome, we demonstrated that a simple physical activity intervention was feasible in this population and has the potential to decrease the AoR dilation rate. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03567460.

28 November 2022 in Children
Verified
Journal Article
Open access
PDF file
DSDanielle Sganga
Danielle Sganga
SBSarina Behera
Sarina Behera
MBMeaghan Beattie
Meaghan Beattie
KSKatie Jo Stauffer
Katie Jo Stauffer
ABAubrey Burlinson
Aubrey Burlinson
Elif Seda Selamet TierneyElif Seda Selamet Tierney
Elif Seda Selamet Tierney
Transthoracic echocardiography (TTE) is an essential tool for diagnosis and management of congenital heart disease. Pediatric echocardiography presents unique challenges including complex anatomy, variable patient cooperation and provider expertise. Diagnostic errors inevitably occur. We designed a collaborative and stepwise quality improvement (QI) process to address diagnostic errors within our laboratory. We retrospectively reviewed medical records to identify diagnostic TTE errors in 100 consecutive cardiac surgery patients ≤ 5 years old (July 2020–January 2021). We identified 18 diagnostic errors. Most errors had minor impact (14/18), and 13 were preventable or possibly preventable. We presented these results to our sonographers and faculty and requested input on preventing and managing diagnostic errors. Our root cause analysis based on their responses yielded 7 areas for improvement (imaging, reporting, systems, time, environment, people, QI processes). Our faculty and sonographers chose QI processes and imaging as initial areas for intervention. We defined our SMART goal as a 10% reduction in diagnostic errors. We implemented interventions focused on QI processes. On initial follow up in May 2022, we identified 7 errors in 70 patients (44% reduction in error rate). Utilizing a stepwise and team-based approach, we successfully developed QI initiatives in our echocardiography laboratory. This approach can serve as a model for a collaborative QI process in other institutions.

19 September 2016 in Echocardiography
Verified
Journal Article
Closed access
PDF file
KSKatie Jo Stauffer
Katie Jo Stauffer
AAAlisa Arunamata
Alisa Arunamata
SVShreyas Vasanawala
Shreyas Vasanawala
SBSarina K. Behera
Sarina K. Behera
AKAlaina K. Kipps
Alaina K. Kipps
NSNorman H. Silverman
Norman H. Silverman

24 June 2022 in Cardiology in the Young
Verified
Journal Article
Closed access
PDF file
KSKatie J. Stauffer
Katie J. Stauffer
JBJerrid Brabender
Jerrid Brabender
CRCharitha D. Reddy
Charitha D. Reddy
ETElif Seda Selamet Tierney
Elif Seda Selamet Tierney
LLLeo Lopez
Leo Lopez
RPRajesh Punn
Rajesh Punn
Background:Intraoperative imaging determines the integrity of surgical repairs. Transoesophageal echocardiography represents standard care for intraoperative imaging in CHD. However, some conditions preclude its use, and epicardial echocardiography is used alternatively. Minimal literature exists on the impact of epicardial echocardiography versus transoesophageal echocardiography. We aimed to evaluate accuracy between the two modalities and hypothesised higher imaging error rates for epicardial echocardiography.Methods:We retrospectively reviewed all epicardial echocardiograms performed over 16 years and compared them to an age- and procedure-matched, randomly selected transoesophageal echocardiography cohort. We detected un- or misidentified cardiac lesions during the intraoperative imaging and evaluated patient outcomes. Data are presented as a median with a range, or a number with percentages, with comparisons by Wilcoxon two-sample test and Fisher’s exact test.Results:Totally, 413 patients comprised the epicardial echocardiography group with 295 transoesophageal echocardiography matches. Rates of imaging discrepancies, re-operation, and incision infection were similar. About 13% of epicardial echocardiography patients had imaging discrepancies versus 16% for transoesophageal (p = 0.2352), the former also had smaller body sizes (p < 0.0001) and more genetic abnormalities (33% versus 19%, p < 0.0001). Death/mechanical support occurred more frequently in epicardial echocardiography patients (16% versus 6%, p < 0.0001), while hospitalisations were longer (25 versus 19 days, p = 0.0003).Conclusions:Diagnostic accuracy was similar between patients undergoing epicardial echocardiography and transoesophageal echocardiography, while rates of death and mechanical support were increased in this inherently higher risk patient population. Epicardial echocardiography provides a reasonable alternative when transoesophageal echocardiography is not feasible.