14 June 2024 in Journal of Lightwave Technology
Optical carrier-suppressed single sideband (OCSSSB) signals are known for their easy detection, low noise, and high energy efficiency. Here, we develop a high-performance OCSSSB signal generation system utilizing an integrated TFLN inphase/quadrature (IQ) modulator, along with an automatic bias control (ABC) module. Our device can achieve a side-mode suppression ratio (SMSR) surpassed 20 dB, optimally reaching up to 29.53 dB, which covers a large electrical-optic bandwidth and central wavelength range. For long-term stability, the peak–to– peak fluctuation of SMSR was measured to be 1.79 dB, with an average SMSR value of 23.47 dB for nearly 8 hours. Furthermore, we successfully demonstrate that our device can be implemented in a frequency-modulated continuous-wave (FMCW) ranging detection, allowing the standard deviation no more than ±2.60 mm. Our system offers substantial potential for direct application in various chip-scale integrated fields, including LIDAR and microwave photonics.
1 October 2020 in Review of Scientific Instruments
Light shift produced by the AC Stark effect is one of the major factors limiting the accuracy and long-term stability of a cold atom interferometer. The first order light shift can be canceled by fixing the power ratio of the Raman beams at a specified value. We report here a new method to stabilize the power ratio of the two Raman lasers with ∼100 kHz locking bandwidth, suppressing the effect of the first order light shift. We first mixed the two Raman lasers (at different optical frequencies) with a reference beam and then used two Schottky diode detectors to extract the corresponding beat note signals for each beam, which are much easier to be manipulated and processed as they are in the microwave band. The stability of the power ratio is improved by three orders of magnitude from 5.84 × 10−3 to 3.51 × 10−6 at 1 s averaging time and reaches 1.59 × 10−7 at 10 000 s integrating time when the servo loop is engaged. This method can be used in other precise quantum measurement based on the stimulated Raman transition and can be applied to compact inertial sensors.
1 March 2021 in Review of Scientific Instruments
Phase noise of Raman lasers is a major source of noise for a Raman-type cold atom interferometer, which is traditionally measured using the signal source analyzer. We report here an atom-based method to measure the phase noise performance between two Raman lasers. By analyzing and calibrating the system noise sources, we can characterize the contribution of phase noise from the total deviation of the relative atom population at the middle of the interference fringe. Knowing the transfer function specified by the operation sequence of the interferometer, we can obtain the transfer function and power spectrum density of the phase noise term. By varying the time sequences of the interferometer, we can measure the white phase noise floor and the phase noise performance over a large range of Fourier frequencies from 1 to 100 000 Hz with a minor difference of 1 dB compared with results from the traditional method using a signal analyzer, which proves the validity of the atom-based method. Compared with the traditional measurement method, the atom-based method can have higher accuracy and have the ability of self-calibrating.
5 May 2025 in IEEE Sensors Journal
Absolute dynamic gravimeters based on cold-atom interferometry provide a promising and efficient approach for gravity mapping. However, there is currently a lack of experimental and quantitative evaluations of the spatial resolution of dynamic atom gravimeters. In this study, we propose a method to test the performance of a shipborne atom gravimeter, wherein the spatial resolution is experimentally evaluated based on acceleration variations induced by the E¨ otv ¨os effect. We developed a shipborne atom gravimeter and conducted a dynamic measurement experiment in a meandering river. The experimental results demonstrate that our shipborne gravimeter achieves a spatial resolution of 525 m. The internal consistency precision of our gravimeter is estimated to be 0.64 mGal, while the external consistency precision is 0.84 mGal. In addition, we demonstrated the adaptability of our gravimeter to diverse survey lines and validated its potential for applications in complex terrains such as meandering rivers and narrow lakes.
1 September 2020 in AIP Advances
In a cold atom interferometer, a bias magnetic field, usually generated by a solenoid or a set of coils, is used to select specific Raman transitions of atoms in the interference region, and its inhomogeneity leads to a Zeeman-effect-induced error for the measurement. To improve the measurement’s accuracy further, we propose a simple method to compensate for the non-uniformity of the bias field by reversing the direction and tuning the value of the current running through the pair of quadrupole coils used for magneto-optical trap (MOT). To smoothen the field with MOT coils, the current applied should be controlled timely and precisely, which was done with a fast-responding electric circuit we designed and built. We also used Raman spectroscopy to characterize the magnetic field profile without and with our method applied, which shows that the length of the homogeneous field (where the fluctuation of magnetic strength is less than 10%) is expanded from 81.87 mm to 101.64 mm. From our calculations, with the free evolution time T of 30 ms, the quadratic Zeeman-effect-induced phase shift Δϕzeeman can be reduced by 76%, which reduces the quadratic Zeeman-effect-induced error of measured gravity Δgzeeman to a quarter of that without our method applied (from 1.745 mGal to 0.418 mGal). Simulation and experiment prove that this method is effective. This method can also be used in other atom interferometers, especially compact systems.
16 May 2022 in IEEE Transactions on Instrumentation and Measurement
One important parameter in estimating the uncertainty of an atom gravimeter is the equivalent height due to the presence of non-negligible vertical gravity gradient. In this paper, we report a novel method to determine the equivalent height based on the location-dependent Rabi frequency produced by modulating Raman lasers. We theoretically investigate this method and apply it on an atom gravimeter. Experimental results reveal that with this new method, 0.06 μGal uncertainty in gravitational acceleration can be achieved when taking the measurement uncertainty of the equivalent height (0.26247 m ± 0.00021 m) as the only contribution. This uncertainty is negligible compared to the current state-of-the-art gravity measurement uncertainty of 2-5 μGal. The demonstrated method can be widely applicable in most of the existing atom gravimeters for the evaluation of their equivalent height, especially those for high-precision metrology and fundamental physics test.