Alice Lorenzati

Alice Lorenzati

Auto-generated profile, based on publicly available information

Alice Lorenzati

Department of Energy, Politecnico di Torino, 10129 Turin, Italy

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Energy and Buildings
Verified
Journal Article
Closed access
Stefano FantucciStefano Fantucci
Stefano Fantucci
ALAlice Lorenzati
Alice Lorenzati
Alfonso CapozzoliAlfonso Capozzoli
Alfonso Capozzoli
Marco PerinoMarco Perino
Marco Perino

1 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
VFVirginia Isabella Fissore
Virginia Isabella Fissore
GAGiuseppina Arcamone
Giuseppina Arcamone
Arianna AstolfiArianna Astolfi
Arianna Astolfi
ABAlberto Barbaro
Alberto Barbaro
Alessio CarulloAlessio Carullo
Alessio Carullo
Louena ShtrepiLouena Shtrepi
Louena Shtrepi
The Indoor Environmental Quality (IEQ) combines thermal, visual, acoustic, and air-quality conditions in indoor environments and affects occupants’ health, well-being, and comfort. Performing continuous monitoring to assess IEQ is increasingly proving to be important, also due to the large amount of time that people spend in closed spaces. In the present study, the design, development, and metrological characterization of a low-cost multi-sensor device is presented. The device is part of a wider system, hereafter referred to as PROMET&O (PROactive Monitoring for indoor EnvironmenTal quality & cOmfort), that also includes a questionnaire for the collection of occupants’ feedback on comfort perception and a dashboard to show end users all monitored data. The PROMET&O multi-sensor monitors the quality conditions of indoor environments thanks to a set of low-cost sensors that measure air temperature, relative humidity, illuminance, sound pressure level, carbon monoxide, carbon dioxide, nitrogen dioxide, particulate matter, volatile organic compounds, and formaldehyde. The device architecture is described, and the design criteria related to measurement requirements are highlighted. Particular attention is paid to the calibration of the device to ensure the metrological traceability of the measurements. Calibration procedures, based on the comparison to reference standards and following commonly employed or ad hoc developed technical procedures, were defined and applied to the bare sensors of air temperature and relative humidity, carbon dioxide, illuminance, sound pressure level, particulate matter, and formaldehyde. The next calibration phase in the laboratory will be aimed at analyzing the mutual influences of the assembled multi-sensor hardware components and refining the calibration functions.