Shibo Lu

Shibo Lu

Auto-generated profile, based on publicly available information

Shibo Lu

School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, NSW, Australia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
SLShibo Lu
Shibo Lu
BPB.T. Phung
B.T. Phung
DZDaming Zhang
Daming Zhang

4 April 2019 in IEEE Access
Verified
Journal Article
Open access
SLShibo Lu
Shibo Lu
TSTharmakulasingam Sirojan
Tharmakulasingam Sirojan
BPB. T. Phung
B. T. Phung
DZDaming Zhang
Daming Zhang
EAEliathamby Ambikairajah
Eliathamby Ambikairajah

7 November 2018 in IEEE Transactions on Sustainable Computing
Verified
Journal Article
Closed access
TSTharmakulasingam Sirojan
Tharmakulasingam Sirojan
SLShibo Lu
Shibo Lu
Toan PhungToan Phung
Toan Phung
DZDaming Zhang
Daming Zhang
EAEliathamby Ambikairajah
Eliathamby Ambikairajah

13 October 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LSLeonardo Silvestri
Leonardo Silvestri
YCYingge Chen
Yingge Chen
ZBZourab Brodzeli
Zourab Brodzeli
TSTharmakulasingam Sirojan
Tharmakulasingam Sirojan
SLShibo Lu
Shibo Lu
FLFrancois Ladouceur
Francois Ladouceur
We propose herein a novel optical sensing technology using liquid crystal based transducers to measure simultaneously voltage and current from overhead power lines in real time. Doing so, we implemented a proof-of-principle system based on this approach and we demonstrated not only good accuracy, but also small phase shift and adequate bandwidth for power quality and fault monitoring applications. This is supported by experimental results for current, voltage and power monitoring, which include transient measurements and show excellent agreement with commercial reference probes. The system presented in this paper has been developed for single wire earth return (SWER) lines operating at 12.7 kV or 19.1 kV, but can be adapted to work at higher or lower voltages with appropriate modifications. We conclude by discussing the calibration process improvements that would be required for the technology to meet industry standards.

1 November 2017
Verified
Conference Paper
Closed access
SLShibo Lu
Shibo Lu
BPB. T. Phung
B. T. Phung
DZDaming Zhang
Daming Zhang
Photovoltaic (PV) systems are increasingly being used. Due to ageing effects and also the trend toward higher DC voltage level, incidents of DC arc faults in PV systems are becoming more common, which have serious impacts on system stability and human safety. Parallel arcs draw high current compared to series arc faults and so detection of the latter is more challenging. This paper attempts to extract the features of DC series arc fault for condition monitoring purpose, achieved through studying the arc characteristics, carrying out simulation in Matlab/Simulink and laboratory experiments. Different arc models are investigated, and a set of parameters for the heuristic model is formulated for low current arcs. It is shown that the simulated arc by the heuristic model is consistent with experimental data. The arc noise features under electrodes' separation region and steady-arcing states with different gap width are investigated. It is found that the arc noise floor will increase after arc fault occurrence, especially for the frequency band below 50 kHz. This characteristic can be exploited for series DC arc fault detection. Moreover, frequency contents below 5 kHz are relatively more sensitive to change of air gap width.

1 October 2017
Verified
Conference Paper
Closed access
RSRuihao Song
Ruihao Song
SLShibo Lu
Shibo Lu
TSTharmakulasingam Sirojan
Tharmakulasingam Sirojan
BPB. T. Phung
B. T. Phung
EAEliathamby Ambikairajah
Eliathamby Ambikairajah
It is costly to have a conventional three phase electricity supply system to service sparsely-populated rural areas. As a solution, the single wire earth return (SWER) network is widely used which has only one overhead conductor delivering power and the ground is used for the return path. This paper presents an on-line monitoring system, currently under development, to provide real-time power quality information of the SWER lines. The system comprises pole-mounted monitoring units distributed along the SWER feeder and relies on its own independent wireless communications platform for data transmission and control.