Background: Dental radiology is vital for effective diagnosis and treatment. However, exposure to ionizing radiation, even at low doses, can induce health risks, particularly with cumulative exposure. This systematic review aims to determine the knowledge, attitudes, and practices of dentists and staff regarding radiation protection in order to improve safety. Main body: This systematic review searched the PubMed, ScienceDirect, Scopus, Nature, and Google Scholar databases for studies published between 2000 and 2020. The quality of the studies was assessed using the Joanna Briggs Institute's critical appraisal checklist for analytical cross-sectional studies. Out of 1505 studies screened, 19 studies involving 6439 participants were included in the final analysis. 42% of the studies reported adequate knowledge levels in radiation protection, with scores ranging from 54.65 to 81.92%. Significant variability was observed in dentists' knowledge (6–73%) compared to dental students (24.4–81.92%). The proportion of participants exhibiting a positive attitude towards radiation protection measures varied between 16.8% and 84.8%. Effective practices in radiation protection demonstrated significant diversity, with scores ranging from 19.8 to 64%. Key recommendations include enhancing initial training (8 studies), implementing continuous education (14 studies), raising awareness (7 studies) and mandating regular recertification (3 studies) for optimal radiation protection practices. Conclusion: The systematic review identified significant gaps in the radiation protection KAP among dentists and dental staff. To promote more consistent and safe practices, it is essential to enhance training and awareness, as well as to standardize radiation protection protocols. Targeted educational interventions and harmonized safety guidelines are necessary to improve the radiation protection culture in the dental field and minimize potential risks to patients and practitioners.
The objective of this study was to establish local diagnostic reference levels (LDRLs) for breast cancer computed tomography imaging in radiotherapy (CT-RT) at a single hospital in Morocco. Data were collected from 106 adult breast cancer patients aged between 33 and 78 yr during five months. Data were obtained using a Hitachi Supria 16-slice CT simulator at a regional oncology center in Morocco. CT-RT images are intended for 3D conformal radiotherapy treatment planning. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for CT-RT breast cancer. LDRLs for CT-RT breast cancer have been determined in terms of DLP and CTDIvol, and they were 330.4 mGy.cm and 6.8 mGy, respectively. The DRLs were compared with other Europeans study. DRLs for this study were lower than those for the United Kingdom (UK), Croatia and Slovenia. The results of this study can be a reference for the establishment of local and national DRLs in Morocco and the optimization of CT-RT breast cancer procedures.
Background: Levofloxacin is a third-generation fluoroquinolone that has several advantages over its (R) ofloxacin isomer. It is used to treat different types of infection, including urinary infection and prostatitis. Objective: A new HPLC method for the enantioselective separation of levofloxacin and its chiral impurity was developed and validated to improve the separation of the enantiomers of levofloxacin [impurity(R) and active principle (S)] by increasing the value of the resolution between the eutomer and the distomer. Method: Chromatographic separation was performed on a Prodigy ODS -2, 5 µm 4.6 × 150 mm column, with a gradient of buffer solution and methanol (80:20, v/v). A Box–Behnken design was considered when optimizing the enantioseparation involving the effects of many factors such as the concentration of d-phenylalanine, the pH of the buffer, the percentage of organic modifier in the mobile phase, the flow rate, the temperature of the column, and the type of column. Results: Chiral separation was achieved with an optimal resolution of 3.8. The method was successfully validated following the International Conference on Harmonization Q2 (R1) guideline, fulfilling the acceptance criteria for selectivity [no interference in the retention time of (S) levofloxacin and (R) levofloxacin], linearity (r ≥0.999 in the range 1.25–3.75 µg/mL for all enantiomers), and precision (RSD <2%). Accuracy was assessed by the application of the analytical method to an analyte of known purity, providing evidence for the usefulness of this monitoring system. Conclusions: The method was successfully used for the determination of levofloxacin impurity in raw material and pharmaceutical dosage forms. Highlights: The following method is accurate and robust to quantify and characterize the presence of levofloxacin impurity in raw material for pharmaceutical compounds.
Background: Monitoring impurities in drug products is a principal requirement of pharmaceutical regulatory authorities all over the world to ensure drug safety. For this reason, there is a great need for analytical QC of dugs products. Objective: In this study, a simple, efficient, and direct HPLC method was developed for the determination of three impurities of diclofenac. Methods: The HPLC method was developed using a mobile phase which consisted of an HPLC grade mixture, acetonitrile–0.01M phosphoric acid adjusted to pH 2.3 (1 + 3, by volume). Results: The separation was performed in 15 min. The calibration curves of the three impurities were linear; the correlation coefficients were 0.999 at concentrations of 0.00015–0.003 µg/mL. Conclusion: The validation of this method shows that it meets all validation criteria. This shows the reliability of this method for the routine control of diclofenac impurities. Highlights: The validation of a robust HPLC method for the determination of diclofenac impurities is of great importance for the pharmaceutical industry to control its products.
20 December 2023 in Annales Pharmaceutiques Françaises