23 April 2012 in Superconductor Science and Technology
4 December 2014 in IEEE Transactions on Applied Superconductivity
The fourth China TF conductor sample (TFCN4) for Phase II, the left leg of the fifth China TF conductor sample (TFCN5) for Phase III, as well as the right leg of the TFCN5 conductor for Phase IV, were made of the WST strands, cabled by Baosheng, jacketed at ASIPP, and prepared by CRPP following the IO-approved procedure and tested in the SULTAN facility. The T cs test results show that both legs of the TFCN4 and TFCN5 have high T cs performance. Using the electrical method, the T cs was 6.56 K for the left leg of TFCN4 and 6.58 K for the right leg of TFCN4 at 68 kA/10.78 T in the first test and 6.36 K for both legs after 1000 electromagnetic load cycles. In the case of TFCN5, T cs was 6.56 K for the left leg and 6.30 K for the right leg at 68 kA/10.78 T in the first test and 6.33 K for the left leg and 6.02 K for the right leg after 1000 electromagnetic load cycles. According to the SULTAN test result, T cs values of TFCN4 and TFCN5 conductor samples meet the ITER acceptance criteria.
1 September 2012 in Plasma Science and Technology
According to the International Thermonuclear Experimental Reactor (ITER) Procurement Arrangement (PA) of Cable-In-Conduit Conductor (CICC) unit lengths for the Toroidal Field (TF) and Poloidal Field (PF) magnet systems of ITER, at the start of process qualification, the Domestic Agency (DA) shall be required to conduct a benchmarking of the room and low temperature acceptance tests carried out at the Strand Suppliers and/or at its Reference Laboratories designated by the ITER Organization (IO). The first benchmarking was carried out successfully in 2009. Nineteen participants from six DAs (China, European Union, Japan, South Korea, Russia, and the United States) participated in the first benchmarking. Bronze-route (BR) Nb3Sn strand and samples prepared by the ITER reference lab (CERN) were sent out to each participant by CERN. In this paper, the test facility and test results of the first benchmarking by the Chinese DA (CNDA) are presented.
19 February 2014 in IEEE Transactions on Applied Superconductivity
The design of poloidal field (PF) coils and correction coils (CCs) for the International Thermonuclear Experimental Reactor (ITER) relies on the use of 45-kA NbTi cable-in-conduit conductors. All PF5 and CC conductors are produced in China. Research and development programs are needed to acquire knowledge on the behavior of such conductors. Since the conductors are new, full-size copper dummy conductors have been produced in advance for testing the cabling parameters, the definition of the automatic tungsten-inert-gas welding of a seamless jacket section, the elaboration of cable insertion, compaction, etc. Then, two short qualification conductor samples (the PF5 and the CC) are manufactured at the Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP), Hefei, China, with the NbTi advanced strands produced by the Western Superconducting Technologies Company, Ltd. In this paper, the manufacturing procedures for the two PF5 and CC conductor samples are described in detail.
18 January 2016 in IEEE Transactions on Applied Superconductivity
The correction busbar (CB) conductors for the ITER project are being produced in China. The second China CB conductor sample (CBCN2, Phase II of conductor testing) and the third CB conductor sample (CBCN3, Phase III testing) were made of the WST NbTi strands, cabled by Changtong, jacketed at ASIPP, and tested in the SULTAN facility. The current sharing (Tcs) test results show that the conductor sections of CBCN2 and CBCN3 have high Tcs performance. Using the electrical method, the Tcs of both CBCN2 and CBCN3 samples was 7.50 K at 10 kA /2.9 T (maximum operating field) before and after electromagnetic loading. AC loss measurement was performed before any electromagnetic loading of the sample and the measurements were repeated after 1000 or 2000 cyclic loads. The AC loss measurements were performed at 2 T background field, without transport current. The AC loss of the CBCN2 and CBCN3 conductors slightly differs at ±0.2T AC field and various frequencies. According to the SULTAN test result, Tcs of CBCN2 and CBCN3 conductor samples meet the ITER acceptance criteria of 7.0 K at Bpeak field is 2.9 T and 10 kA.