Zhuohe Liu

Zhuohe Liu

Auto-generated profile, based on publicly available information

Zhuohe Liu

Department of Neuroscience, Baylor College of Medicine, Houston, TX, 77030, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2022 in Cell
Verified
Journal Article
Open access
ZLZhuohe Liu
Zhuohe Liu
XLXiaoyu Lu
Xiaoyu Lu
VVVincent Villette
Vincent Villette
YGYueyang Gou
Yueyang Gou
KCKevin L. Colbert
Kevin L. Colbert
FSFrançois St-Pierre
François St-Pierre
Genetically encoded voltage indicators are emerging tools for monitoring voltage dynamics with cell-type specificity. However, current indicators enable a narrow range of applications due to poor performance under two-photon microscopy, a method of choice for deep-tissue recording. To improve indicators, we developed a multiparameter high-throughput platform to optimize voltage indicators for two-photon microscopy. Using this system, we identified JEDI-2P, an indicator that is faster, brighter, and more sensitive and photostable than its predecessors. We demonstrate that JEDI-2P can report light-evoked responses in axonal termini of Drosophila interneurons and the dendrites and somata of amacrine cells of isolated mouse retina. JEDI-2P can also optically record the voltage dynamics of individual cortical neurons in awake behaving mice for more than 30 min using both resonant-scanning and ULoVE random-access microscopy. Finally, ULoVE recording of JEDI-2P can robustly detect spikes at depths exceeding 400 μm and report voltage correlations in pairs of neurons.

23 October 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
JLJihwan Lee
Jihwan Lee
ZLZhuohe Liu
Zhuohe Liu
PSPeter H. Suzuki
Peter H. Suzuki
JAJohn F. Ahrens
John F. Ahrens
SLShujuan Lai
Shujuan Lai
FSFrançois St-Pierre
François St-Pierre
Versatile high-throughput method can isolate single cells based on spatiotemporal phenotypes.

12 October 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
XLXiaoyu Lu
Xiaoyu Lu
YWYunmiao Wang
Yunmiao Wang
ZLZhuohe Liu
Zhuohe Liu
YGYueyang Gou
Yueyang Gou
DJDieter Jaeger
Dieter Jaeger
FSFrançois St-Pierre
François St-Pierre
Widefield imaging with genetically encoded voltage indicators (GEVIs) is a promising approach for understanding the role of large cortical networks in the neural coding of behavior. However, the limited performance of current GEVIs restricts their deployment for single-trial imaging of rapid neuronal voltage dynamics. Here, we developed a high-throughput platform to screen for GEVIs that combine fast kinetics with high brightness, sensitivity, and photostability under widefield one-photon illumination. Rounds of directed evolution produced JEDI-1P, a green-emitting fluorescent indicator with enhanced performance across all metrics. Next, we optimized a neonatal intracerebroventricular delivery method to achieve cost-effective and wide-spread JEDI-1P expression in mice. We also developed an approach to correct optical measurements from hemodynamic and motion artifacts effectively. Finally, we achieved stable brain-wide voltage imaging and successfully tracked gamma-frequency whisker and visual stimulations in awake mice in single trials, opening the door to investigating the role of high-frequency signals in brain computations.

14 December 2021 in Current Biology
Verified
Journal Article
Closed access
CBChristian Behrens
Christian Behrens
SYShubhash Chandra Yadav
Shubhash Chandra Yadav
MKMaria M. Korympidou
Maria M. Korympidou
YZYue Zhang
Yue Zhang
SHSilke Haverkamp
Silke Haverkamp
TSTimm Schubert
Timm Schubert

4 April 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
JLJihwan Lee
Jihwan Lee
SLShujuan Lai
Shujuan Lai
SYShuyuan Yang
Shuyuan Yang
SZShiqun Zhao
Shiqun Zhao
FBFrancisco A. Blanco
Francisco A. Blanco
FSFrançois St-Pierre
François St-Pierre
Fluorescent proteins are indispensable molecular tools for visualizing biological structures and processes, but their limited photostability restricts the duration of dynamic imaging experiments. Yellow fluorescent proteins (YFPs), in particular, photobleach rapidly. Here, we introduce mGold2s and mGold2t, YFPs with up to 25-fold greater photostability than mVenus and mCitrine, two commonly used YFPs, while maintaining comparable brightness. These variants were identified using a high-throughput pooled single-cell platform, simultaneously screening for high brightness and photostability. Compared with our previous benchmark, mGold, the mGold2 variants display a ~4-fold increase in photostability without sacrificing brightness. mGold2s and mGold2t extend imaging durations across diverse modalities, including widefield, total internal reflection fluorescence (TIRF), super-resolution, single-molecule, and laser-scanning confocal microscopy. When incorporated into fluorescence resonance energy transfer (FRET)-based biosensors, the proposed YFPs enable more reliable, prolonged imaging of dynamic cellular processes. Overall, the enhanced photostability of mGold2s and mGold2t enables high-sensitivity imaging of subcellular structures and cellular activity over extended periods, broadening the scope and precision of biological imaging.

15 April 2026 in Nature Methods
Verified
Journal Article
Open access
PDF file
MLMichelle A. Land
Michelle A. Land
MGMario Galdamez
Mario Galdamez
VVVincent Villette
Vincent Villette
Jun ZhuJun Zhu
Jun Zhu
XLXiaoyu Lu
Xiaoyu Lu
FSFrançois St-Pierre
François St-Pierre
Subthreshold voltage dynamics are essential for neuronal information integration, yet they remain technically challenging to measure in vivo. While genetically encoded voltage indicators are emerging as powerful tools for voltage recording, they lack the sensitivity to detect millivolt-scale subthreshold fluctuations with two-photon microscopy—the method of choice for deep-tissue recording. To overcome this limitation, we engineered two genetically encoded voltage indicators, JEDI3sub and JEDI3hyp, with enhanced subthreshold voltage detection under two-photon excitation. In the mouse brain, JEDI3sub enabled simultaneous tracking of subthreshold optical tuning from over 100 cells simultaneously, while JEDI3hyp captured subthreshold dynamics associated with sharp-wave ripples in hippocampal PV+ interneurons. Moreover, JEDI3hyp supported prolonged imaging of brain-state-dependent, millivolt-scale subthreshold voltage changes across deep-layer somas, fine dendritic structures and diverse cell types. By enabling sensitive reporting of subthreshold voltage dynamics, JEDI3 indicators open previously unexplored avenues for dissecting neural information processing in health and disease.