Osama Haddad

Osama Haddad

Auto-generated profile, based on publicly available information

Osama Haddad

Department of Cardiothoracic Surgery, Mayo Clinic Hospital , 4500 San Pablo Rd S, Jacksonville, FL, 32224

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2023 in ESC Heart Failure
Verified
Journal Article
Open access
OHOsama Haddad
Osama Haddad
BSBasar Sareyyupoglu
Basar Sareyyupoglu
RGRohan M. Goswami
Rohan M. Goswami
MBMacit Bitargil
Macit Bitargil
PPParag C. Patel
Parag C. Patel
SPSi M. Pham
Si M. Pham
Aims: We sought to investigate the outcomes of heart transplant patients supported with Impella 5.5 temporary mechanical circulatory support. Methods and results: Patient demographics, perioperative data, hospital timeline, and haemodynamic parameters were followed during initial admission, Impella support, and post-transplant period. Vasoactive-inotropic score, primary graft failure, and complications were recorded. Between March 2020 and March 2021, 16 advanced heart failure patients underwent Impella 5.5 temporary left ventricular assist device support through axillary approach. Subsequently, all these patients had heart transplantation. All patients were either ambulatory or chair bound during their temporary mechanical circulatory support until heart transplantation. Patients were kept on Impella support median of 19 days (3–31) with the median lactate dehydrogenase level of 220 (149–430). All Impella devices were removed during heart transplantation. During Impella support, patients had improved renal function with median creatinine serum level of 1.55 mg/dL decreased to 1.25 (P = 0.007), pulmonary artery pulsatility index scores increased from 2.56 (0.86–10) to 4.2 (1.3–10) (P = 0.048), and right ventricular function improved (P = 0.003). Patients maintained improved renal function and favourable haemodynamics after their heart transplantation as well. All patients survived without any significant morbidity after their heart transplantation. Conclusions: Impella 5.5 temporary left ventricular assist device optimizes care of heart transplant recipients providing superior haemodynamic support, mobility, improved renal function, pulmonary haemodynamics, and right ventricular function. Utilizing Impella 5.5 as a direct bridging strategy to heart transplantation resulted in excellent outcomes.

20 May 2022 in Clinical Transplantation
Verified
Journal Article
Closed access
MBMacit Bitargil
Macit Bitargil
OHOsama Haddad
Osama Haddad
SPSi Pham
Si Pham
NGNeha Garg
Neha Garg
SJSamuel Jacob
Samuel Jacob
BSBasar Sareyyupoglu
Basar Sareyyupoglu

20 January 2022 in Journal of Cardiac Surgery
Verified
Journal Article
Closed access
PDF file
MBMacit Bitargil
Macit Bitargil
OHOsama Haddad
Osama Haddad
SPSi Pham
Si Pham
RGRohan M. Goswami
Rohan M. Goswami
PPParag C. Patel
Parag C. Patel
BSBasar Sareyyupoglu
Basar Sareyyupoglu

11 July 2020 in Journal of Cardiac Surgery
Verified
Journal Article
Closed access
PDF file
OHOsama Haddad
Osama Haddad
APAnthony N. Pham
Anthony N. Pham
MTMathew Thomas
Mathew Thomas
MAMojahid Ali
Mojahid Ali
BSBasar Sareyyupoglu
Basar Sareyyupoglu
SPSi Pham
Si Pham

10 November 2015 in Oman Medical Journal
Verified
Journal Article
Open access
MAMaher A. Al-Khawaldeh
Maher A. Al-Khawaldeh
OHOsama K. Haddad
Osama K. Haddad
AAAshraf O. Alshabatat
Ashraf O. Alshabatat
SDSalil V. Deo
Salil V. Deo
ARAbeer Rababah
Abeer Rababah
SASalah E. Altarabsheh
Salah E. Altarabsheh
Ischemic stroke following cardiac surgery is one of the devastating complications that surgeons may encounter, and may lead to serious disabilities for the patient. The clinical course of such a complication may be prolonged if it is not treated properly. Making a quick decision when choosing a revascularization method is very helpful in this matter. Effective treatment options are usually limited. Neurointerventional maneuvers have recently emerged as a possible therapeutic modality in this field. We present the case of a 52-year-old woman who had open heart surgery in Queen Alia Heart Institute, Jordan, to replace a severely stenotic rheumatic mitral valve and repair a leaking tricuspid valve. Her surgery went smoothly with no major event. However, she developed a massive ischemic stroke during her recovery period despite being on adequate anticoagulation therapy. Urgent radiological work-up confirmed the diagnosis of ischemic stroke in the territory of the right middle cerebral artery. We chose a neuro-interventional method for her treatment, and mechanical thrombectomy was performed with a successful outcome and no apparent complications.

2 September 2022 in Transplantation Proceedings
Verified
Journal Article
Closed access
SJSamuel Jacob
Samuel Jacob
MAMagdy M. El-Sayed Ahmed
Magdy M. El-Sayed Ahmed
OHOsama K. Haddad
Osama K. Haddad
DODavid Orlando
David Orlando
CLCarolyn Landolfo
Carolyn Landolfo
SPSi Pham
Si Pham