Marc-André Tétrault

Marc-André Tétrault

Auto-generated profile, based on publicly available information

Marc-André Tétrault

Faculté des Sciences, Université de Sherbrooke, 2500 Bd de l'Université, Sherbrooke, Quebec J1K 2R1

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2010 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MTM.-A. Tetrault
M.-A. Tetrault
JOJ. F. Oliver
J. F. Oliver
MBM. Bergeron
M. Bergeron
RLRoger Lecomte
Roger Lecomte
RFR. Fontaine
R. Fontaine
Coincidence engines follow two main implementation flows: timestamp based systems and AND-gate based systems. The latter have been more widespread in recent years because of its lower cost and high efficiency. However, they are highly dependent on the selected electronic components, they have limited flexibility once assembled and they are customized to fit a specific scanner's geometry. Timestamp based systems are gathering more attention lately, especially with high channel count fully digital systems. These new systems must however cope with important singles count rates. One option is to record every detected event and postpone coincidence detection offline. For daily use systems, a real time engine is preferable because it dramatically reduces data volume and hence image preprocessing time and raw data management. This paper presents the timestamp based coincidence engine for the LabPET¿, a small animal PET scanner with up to 4608 individual readout avalanche photodiode channels. The engine can handle up to 100 million single events per second and has extensive flexibility because it resides in programmable logic devices. It can be adapted for any detector geometry or channel count, can be ported to newer, faster programmable devices and can have extra modules added to take advantage of scanner-specific features. Finally, the user can select between full processing mode for imaging protocols and minimum processing mode to study different approaches for coincidence detection with offline software.

26 March 2023 in NeuroImage
Verified
Journal Article
Open access
YCYanis Chemli
Yanis Chemli
MTMarc-André Tétrault
Marc-André Tétrault
TMThibault Marin
Thibault Marin
MNMarc D. Normandin
Marc D. Normandin
IBIsabelle Bloch
Isabelle Bloch
YPYoann Petibon
Yoann Petibon
Super-resolution (SR) is a methodology that seeks to improve image resolution by exploiting the increased spatial sampling information obtained from multiple acquisitions of the same target with accurately known sub-resolution shifts. This work aims to develop and evaluate an SR estimation framework for brain positron emission tomography (PET), taking advantage of a high-resolution infra-red tracking camera to measure shifts precisely and continuously. Moving phantoms and non-human primate (NHP) experiments were performed on a GE Discovery MI PET/CT scanner (GE Healthcare) using an NDI Polaris Vega (Northern Digital Inc), an external optical motion tracking device. To enable SR, a robust temporal and spatial calibration of the two devices was developed as well as a list-mode Ordered Subset Expectation Maximization PET reconstruction algorithm, incorporating the high-resolution tracking data from the Polaris Vega to correct motion for measured line of responses on an event-by-event basis. For both phantoms and NHP studies, the SR reconstruction method yielded PET images with visibly increased spatial resolution compared to standard static acquisitions, allowing improved visualization of small structures. Quantitative analysis in terms of SSIM, CNR and line profiles were conducted and validated our observations. The results demonstrate that SR can be achieved in brain PET by measuring target motion in real-time using a high-resolution infrared tracking camera.

1 October 2011
Verified
Conference Paper
Closed access
MBMelanie Bergeron
Melanie Bergeron
CTChristian Thibaudeau
Christian Thibaudeau
JCJules Cadorette
Jules Cadorette
CPCatherine M. Pepin
Catherine M. Pepin
MTMarc-Andre Tetrault
Marc-Andre Tetrault
RLRoger Lecomte
Roger Lecomte
CT imaging is currently the standard modality to provide anatomical reference in PET molecular imaging. Since both PET and CT rely on detecting radiation to generate images, it would make sense to use the same detection system for data acquisition. Merging PET and CT hardware imposes stringent requirements on detectors, including wide dynamic range with high signal-to-noise ratio for good energy resolution in both modalities, high pixellisation for high spatial resolution, and very high count rate capabilities. The APD-based LabPET II module is proposed as the building block for a truly combined PET/CT scanner. The module is made of two 4 × 8 APD pixel monolithic arrays mounted side by side unto a custom ceramic holder, with each element having an active area of 1.1 × 1.1 mm 2 at a 1.2 mm pitch, coupled to a 12-mm high LYSO scintillator block array. While a previous version of the module was made of pyramidal shaped crystals (1.35 × 1.35/1.2 × 1.2 mm 2 , top/bottom), a recent version was designed with a simpler rectangular geometry (1.2 × 1.2 mm 2 ), better reflective material optimizing the shift of refractive index at crystal interface, and enhanced APD quantum efficiency to improve intrinsic detector performance. Mean energy resolution was improved to 20 ± 1% (formerly 24 ± 1%) at 511 keV and to 41 ± 4% (formerly 48 ± 3%) at 60 keV. These intrinsic detector performance characteristics make the LabPET II module suitable for counting CT imaging with efficient energy discrimination. Initial phantom images obtained from a CT test bench demonstrated excellent contrast linearity as a function of material density and spatial resolution of 0.61 mm FWHM/1.1 mm FWTM, corresponding to 1.3 lp/mm at MTF 10% /0.73 lp/mm at MTF 50% , which allowed 0.75 mm air holes in an Ultra Micro resolution phantom to be clearly distinguished.

1 October 2016
Verified
Conference Paper
Closed access
LNLarissa Njejimana
Larissa Njejimana
LALouis Arpin
Louis Arpin
CTChristian Thibaudeau
Christian Thibaudeau
NJNadia Jurgensen
Nadia Jurgensen
HBHaithem Bouziri
Haithem Bouziri
Rejean FontaineRejean Fontaine
Rejean Fontaine
A new, highly pixelated, PET scanner dedicated to mouse imaging is being developed based on the LabPET II detector module. Each module includes four monolithic array of 4×8 avalanche photodiodes (APD) individually coupled to four 4×8 array of 1.12×1.12 mm 2 scintillator pixels aimed at achieving submillimetric spatial resolution. A PCB routes the signals from four detector arrays to two 64-channel, mixed-signal, Application Specific Integrated Circuit (ASIC), forming a 128-channel readout unit. A new DAQ system was designed to interface this novel detector module. Its firmware architecture consists of 2 types of custom FPGA-based electronic boards processing data from the detector module. An embedded signal processing unit is in charge of data readout, corrections and sorting. It also features live energy histogramming and count rates computation. An FPGA-based coincidence, data communication and gating unit collects data from all embedded signal processing units and deals with coincidence detection together with random estimation and sends processed data to a host computer. In parallel to the detected events stream, a command and control flow was added for ASIC automatic calibration, electronic boards parameters setting and readout from the host computer. This firmware allows a real-time PET data processing without degrading the detector module performance.

25 November 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
LGL. Galli
L. Galli
SKS. Al Kharusi
S. Al Kharusi
TBThomas Brunner
Thomas Brunner
CCC. Chambers
C. Chambers
BCB. Chana
B. Chana
LXL. Xie
L. Xie

4 March 2026 in IEEE Transactions on Quantum Engineering
Verified
Journal Article
Open access
MRMarc-Antoine Roux
Marc-Antoine Roux
JRJoffrey Rivard
Joffrey Rivard
VYVictor Yon
Victor Yon
AMAlexis Morel
Alexis Morel
DLDominic Leclerc
Dominic Leclerc
EDEva Dupont-Ferrier
Eva Dupont-Ferrier
Spin qubits need to operate within a very precise voltage space around charge state transitions to achieve high-fidelity gates. However, the stability diagrams that allow the identification of the desired charge states are long to acquire. Moreover, the voltage space to search for the desired charge state increases quickly with the number of qubits. Therefore, faster stability diagram acquisitions are needed to scale up a spin qubit quantum processor. Currently, most methods focus on more efficient data sampling. Our approach shows a significant speedup by combining measurement speedup and a reduction in the number of measurements needed to tune a quantum dot device. Using an autotuning algorithm based on a neural network and faster measurements by harnessing the FPGA embedded in Keysight's Quantum Engineering Toolkit (QET), the measurement time of stability diagrams has been reduced by a factor of 9.8. This led to an acceleration factor of 2.2 for the total initialization time of a SiGe quantum dot into the single-electron regime, which is limited by the Python code execution.