David Lohr

David Lohr

Auto-generated profile, based on publicly available information

David Lohr

Chair of Cellular and Molecular Imaging Comprehensive Heart Failure Center (CHFC) University Hospital Wuerzburg Wuerzburg Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MAMarkus J. Ankenbrand
Markus J. Ankenbrand
DLDavid Lohr
David Lohr
WSWiebke Schlötelburg
Wiebke Schlötelburg
TRTheresa Reiter
Theresa Reiter
TWTobias Wech
Tobias Wech
LSLaura Maria Schreiber
Laura Maria Schreiber
Purpose: Artificial neural networks show promising performance in automatic segmentation of cardiac MRI. However, training requires large amounts of annotated data and generalization to different vendors, field strengths, sequence parameters, and pathologies is limited. Transfer learning addresses this challenge, but specific recommendations regarding type and amount of data required is lacking. In this study, we assess data requirements for transfer learning to experimental cardiac MRI at 7T where the segmentation task can be challenging. In addition, we provide guidelines, tools, and annotated data to enable transfer learning approaches by other researchers and clinicians.Methods: A publicly available segmentation model was used to annotate a publicly available data set. This labeled data set was subsequently used to train a neural network for segmentation of left ventricle and myocardium in cardiac cine MRI. The network is used as starting point for transfer learning to 7T cine data of healthy volunteers (n = 22; 7873 images) by updating the pre‐trained weights. Structured and random data subsets of different sizes were used to systematically assess data requirements for successful transfer learning.Results: Inconsistencies in the publically available data set were corrected, labels created, and a neural network trained. On 7T cardiac cine images the model pre‐trained on public imaging data, acquired at 1.5T and 3T, achieved DICELV = 0.835 and DICEMY = 0.670. Transfer learning using 7T cine data and ImageNet weight initialization improved model performance to DICELV = 0.900 and DICEMY = 0.791. Using only end‐systolic and end‐diastolic images reduced training data by 90%, with no negative impact on segmentation performance (DICELV = 0.908, DICEMY = 0.805).Conclusions: This work demonstrates and quantifies the benefits of transfer learning for cardiac cine image segmentation. We provide practical guidelines for researchers planning transfer learning projects in cardiac MRI and make data, models, and code publicly available.

23 July 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MHMichael Hock
Michael Hock
MTMaxim Terekhov
Maxim Terekhov
MSMaria Roxana Stefanescu
Maria Roxana Stefanescu
DLDavid Lohr
David Lohr
SHStefan Herz
Stefan Herz
LSLaura Maria Schreiber
Laura Maria Schreiber
Purpose: Inhomogeneities of the static magnetic B0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio‐temporal B0‐field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state‐of‐the‐art shimming are described, regional B0 variations are measured, and a methodology for spherical harmonics shimming of the B0 field within the human myocardium is proposed.Methods: The spatial B0‐field distribution in the heart was analyzed as well as temporal B0‐field variations in the myocardium over the cardiac cycle. Different shim region‐of‐interest selections were compared, and hardware limitations of spherical harmonics B0 shimming were evaluated by calibration‐based B0‐field modeling. The role of third‐order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase–specific shimming.Results: The strongest B0‐field inhomogeneities were observed in localized spots within the left‐ventricular and right‐ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy‐driven shim region‐of‐interest selection allowed for improved B0‐field homogeneity compared with a standard shim region‐of‐interest cuboid. Third‐order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B0‐field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase–specific shimming was performed, and a shim term‐by‐term analysis revealed periodic variations of required currents.Conclusion: Challenges in state‐of‐the‐art B0 shimming of the human heart at 7 T were described. Cardiac phase–specific shimming strategies were found to be superior to vendor‐supplied shimming.

24 March 2020 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
DLDavid Lohr
David Lohr
MTMaxim Terekhov
Maxim Terekhov
FVFranziska Veit
Franziska Veit
LSLaura Maria Schreiber
Laura Maria Schreiber
In this study we aimed to assess the effects of continuous formalin fixation on diffusion and relaxation metrics of the ex vivo porcine heart at 7 T. Magnetic resonance imaging was performed on eight piglet hearts using a 7 T whole body system. Hearts were measured fresh within 3 hours of cardiac arrest followed by immersion in 10% neutral buffered formalin. T2* and T2 were assessed using a gradient multi‐echo and multi‐echo spin echo sequence, respectively. A spin echo and a custom stimulated echo sequence were employed to assess diffusion time‐dependent changes in metrics of cardiac diffusion tensor imaging. SNR was determined for b = 0 images. Scans were performed for 5 mm thick apical, midcavity and basal slices (in‐plane resolution: 1 mm) and repeated 7, 15, 50, 100 and 200 days postfixation. Eigenvalues of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) decreased significantly (P < 0.05) following fixation. Relative to fresh hearts, FA values 7 and 200 days postfixation were 90% and 80%, while respective relative ADC values at those fixation stages were 78% and 92%. Statistical helix and sheetlet angle distributions as well as respective mean and median values showed no systematic influence of continuous formalin fixation. Similar to changes in the ADC, values for T2, T2* and SNR dropped initially postfixation. Respective relative values compared with fresh hearts at day 7 were 64%, 79% and 68%, whereas continuous fixation restored T2, T2* and SNR leading to relative values of 74%, 100%, and 81% at day 200, respectively. Relaxation parameters and diffusion metrics are significantly altered by continuous formalin fixation. The preservation of microstructure metrics following prolonged fixation is a key finding that may enable future studies of ventricular remodeling in cardiac pathologies.

1 August 2019 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
IEIbrahim A. Elabyad
Ibrahim A. Elabyad
MTM. Terekhov
M. Terekhov
MSM.R. Stefanescu
M.R. Stefanescu
DLD. Lohr
D. Lohr
MFM. Fischer
M. Fischer
LSL.M. Schreiber
L.M. Schreiber

25 March 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DLDavid Lohr
David Lohr
MTMaxim Terekhov
Maxim Terekhov
AWAndreas Max Weng
Andreas Max Weng
ASAnja Schroeder
Anja Schroeder
HWHeike Walles
Heike Walles
LSLaura Maria Schreiber
Laura Maria Schreiber
Purpose of this work was to assess feasibility of cardiac diffusion tensor imaging (cDTI) at 7 T in a set of healthy, unfixed, porcine hearts using various parallel imaging acceleration factors and to compare SNR and derived cDTI metrics to a reference measured at 3 T. Magnetic resonance imaging was performed on 7T and 3T whole body systems using a spin echo diffusion encoding sequence with echo planar imaging readout. Five reference (b = 0 s/mm2) images and 30 diffusion directions (b = 700 s/mm2) were acquired at both 7 T and 3 T using a GRAPPA acceleration factor R = 1. Scans at 7 T were repeated using R = 2, R = 3, and R = 4. SNR evaluation was based on 30 reference (b = 0 s/mm2) images of 30 slices of the left ventricle and cardiac DTI metrics were compared within AHA segmentation. The number of hearts scanned at 7 T and 3 T was n = 11. No statistically significant differences were found for evaluated helix angle, secondary eigenvector angle, fractional anisotropy and apparent diffusion coefficient at the different field strengths, given sufficiently high SNR and geometrically undistorted images. R≥3 was needed to reduce susceptibility induced geometric distortions to an acceptable amount. On average SNR in myocardium of the left ventricle was increased from 29±3 to 44±6 in the reference image (b = 0 s/mm2) when switching from 3 T to 7 T. Our study demonstrates that high resolution, ex vivo cDTI is feasible at 7 T using commercial hardware.

16 May 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
IEIbrahim A. Elabyad
Ibrahim A. Elabyad
MTM. Terekhov
M. Terekhov
MSMaria R. Stefanescu
Maria R. Stefanescu
DLD. Lohr
D. Lohr
MFM. Fischer
M. Fischer
LSLaura M. Schreiber
Laura M. Schreiber
A dedicated, novel, multichannel transmit/receive (Tx/Rx) coil array was designed, simulated, and tested for cardiac magnetic resonance imaging (cMRI) of pigs at 7 T. The cardiac array was composed of 16 elements with physically independent anterior and posterior parts. The array was connected to the MRI scanner in the parallel transmit (pTx) mode forming an 8-channel transmit and 16-channel receive (8Tx/16Rx) coil configuration. The anterior array was composed of four central octagonal elements, which were decoupled using a common central ring (CCR) and shared decoupling capacitors. The surrounding four triangular elements were decoupled from the central four elements using gaps and capacitive decoupling. In total, the eight elements of the anterior array resembled a coil with a symmetrical circular shape. Due to the advantageous arrangement of the elements in conjunction with the novel decoupling method of a CCR, the coupling between the adjacent loop elements was minimized. The posterior array was built using a 4 x 2 standard rectangular, symmetric element configuration. The dedicated cardiac array was tested in phantom and in ex vivo MR measurements with a female pig of 46 kg. The dedicated coil array enhanced the signal-to-noise ratio (40 ± 27) in ex vivo measurements of the pig heart by about three times compared to a coil prototype for cardiac human imaging (11.8 ± 7). High-resolution, ex vivo cardiac images were acquired with an in-plane resolution of up to 0.3 mm x 0.3 mm using the dedicated pig coil array. The novel cardiac array supports parallel imaging with an acceleration factor (R) of 4 without increasing the mean g-factor within the heart region beyond 1.15.