Maxim Terekhov

Maxim Terekhov

Auto-generated profile, based on publicly available information

Maxim Terekhov

Comprehensive Heart Failure Center (D.E.D.A., E.T.M., H.M., M.T., M.K., U.H., S.F., G.C.R.), University Hospital Würzburg, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MHMichael Hock
Michael Hock
MTMaxim Terekhov
Maxim Terekhov
MSMaria Roxana Stefanescu
Maria Roxana Stefanescu
DLDavid Lohr
David Lohr
SHStefan Herz
Stefan Herz
LSLaura Maria Schreiber
Laura Maria Schreiber
Purpose: Inhomogeneities of the static magnetic B0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio‐temporal B0‐field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state‐of‐the‐art shimming are described, regional B0 variations are measured, and a methodology for spherical harmonics shimming of the B0 field within the human myocardium is proposed.Methods: The spatial B0‐field distribution in the heart was analyzed as well as temporal B0‐field variations in the myocardium over the cardiac cycle. Different shim region‐of‐interest selections were compared, and hardware limitations of spherical harmonics B0 shimming were evaluated by calibration‐based B0‐field modeling. The role of third‐order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase–specific shimming.Results: The strongest B0‐field inhomogeneities were observed in localized spots within the left‐ventricular and right‐ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy‐driven shim region‐of‐interest selection allowed for improved B0‐field homogeneity compared with a standard shim region‐of‐interest cuboid. Third‐order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B0‐field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase–specific shimming was performed, and a shim term‐by‐term analysis revealed periodic variations of required currents.Conclusion: Challenges in state‐of‐the‐art B0 shimming of the human heart at 7 T were described. Cardiac phase–specific shimming strategies were found to be superior to vendor‐supplied shimming.

23 July 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TRTheresa Reiter
Theresa Reiter
DLDavid Lohr
David Lohr
MHMichael Hock
Michael Hock
MAMarkus Johannes Ankenbrand
Markus Johannes Ankenbrand
MSMaria Roxana Stefanescu
Maria Roxana Stefanescu
LSLaura Maria Schreiber
Laura Maria Schreiber
Introduction: Cardiac magnetic resonance (CMR) at ultrahigh field (UHF) offers the potential of high resolution and fast image acquisition. Both technical and physiological challenges associated with CMR at 7T require specific hardware and pulse sequences. This study aimed to assess the current status and existing, publicly available technology regarding the potential of a clinical application of 7T CMR. Methods: Using a 7T MRI scanner and a commercially available radiofrequency coil, a total of 84 CMR examinations on 72 healthy volunteers (32 males, age 19–70 years, weight 50–103 kg) were obtained. Both electrocardiographic and acoustic triggering were employed. The data were analyzed regarding the diagnostic image quality and the influence of patient and hardware dependent factors. 50 complete short axis stacks and 35 four chamber CINE views were used for left ventricular (LV) and right ventricular (RV), mono-planar LV function, and RV fractional area change (FAC). Twenty-seven data sets included aortic flow measurements that were used to calculate stroke volumes. Subjective acceptance was obtained from all volunteers with a standardized questionnaire. Results: Functional analysis showed good functions of LV (mean EF 56%), RV (mean EF 59%) and RV FAC (mean FAC 52%). Flow measurements showed congruent results with both ECG and ACT triggering. No significant influence of experimental parameters on the image quality of the LV was detected. Small fractions of 5.4% of LV and 2.5% of RV segments showed a non-diagnostic image quality. The nominal flip angle significantly influenced the RV image quality. Conclusion: The results demonstrate that already now a commercially available 7T MRI system, without major methods developments, allows for a solid morphological and functional analysis similar to the clinically established CMR routine approach. This opens the door towards combing routine CMR in patients with development of advanced 7T technology.

1 August 2019 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
IEIbrahim A. Elabyad
Ibrahim A. Elabyad
MTM. Terekhov
M. Terekhov
MSM.R. Stefanescu
M.R. Stefanescu
DLD. Lohr
D. Lohr
MFM. Fischer
M. Fischer
LSL.M. Schreiber
L.M. Schreiber

16 May 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
IEIbrahim A. Elabyad
Ibrahim A. Elabyad
MTM. Terekhov
M. Terekhov
MSMaria R. Stefanescu
Maria R. Stefanescu
DLD. Lohr
D. Lohr
MFM. Fischer
M. Fischer
LSLaura M. Schreiber
Laura M. Schreiber
A dedicated, novel, multichannel transmit/receive (Tx/Rx) coil array was designed, simulated, and tested for cardiac magnetic resonance imaging (cMRI) of pigs at 7 T. The cardiac array was composed of 16 elements with physically independent anterior and posterior parts. The array was connected to the MRI scanner in the parallel transmit (pTx) mode forming an 8-channel transmit and 16-channel receive (8Tx/16Rx) coil configuration. The anterior array was composed of four central octagonal elements, which were decoupled using a common central ring (CCR) and shared decoupling capacitors. The surrounding four triangular elements were decoupled from the central four elements using gaps and capacitive decoupling. In total, the eight elements of the anterior array resembled a coil with a symmetrical circular shape. Due to the advantageous arrangement of the elements in conjunction with the novel decoupling method of a CCR, the coupling between the adjacent loop elements was minimized. The posterior array was built using a 4 x 2 standard rectangular, symmetric element configuration. The dedicated cardiac array was tested in phantom and in ex vivo MR measurements with a female pig of 46 kg. The dedicated coil array enhanced the signal-to-noise ratio (40 ± 27) in ex vivo measurements of the pig heart by about three times compared to a coil prototype for cardiac human imaging (11.8 ± 7). High-resolution, ex vivo cardiac images were acquired with an in-plane resolution of up to 0.3 mm x 0.3 mm using the dedicated pig coil array. The novel cardiac array supports parallel imaging with an acceleration factor (R) of 4 without increasing the mean g-factor within the heart region beyond 1.15.

6 August 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MTMaxim Terekhov
Maxim Terekhov
IEIbrahim A. Elabyad
Ibrahim A. Elabyad
LSLaura M. Schreiber
Laura M. Schreiber
The development of novel multiple-element transmit-receive arrays is an essential factor for improving B1+ field homogeneity in cardiac MRI at ultra-high magnetic field strength (B0 > = 7.0T). One of the key steps in the design and fine-tuning of such arrays during the development process is finding the default driving phases for individual coil elements providing the best possible homogeneity of the combined B1+-field that is achievable without (or before) subject-specific B1+-adjustment in the scanner. This task is often solved by time-consuming (brute-force) or by limited efficiency optimization methods. In this work, we propose a robust technique to find phase vectors providing optimization of the B1-homogeneity in the default setup of multiple-element transceiver arrays. The key point of the described method is the pre-selection of starting vectors for the iterative solver-based search to maximize the probability of finding a global extremum for a cost function optimizing the homogeneity of a shaped B1+-field. This strategy allows for (i) drastic reduction of the computation time in comparison to a brute-force method and (ii) finding phase vectors providing a combined B1+-field with homogeneity characteristics superior to the one provided by the random-multi-start optimization approach. The method was efficiently used for optimizing the default phase settings in the in-house-built 8Tx/16Rx arrays designed for cMRI in pigs at 7T.

26 April 2022 in NMR in Biomedicine
Verified
Journal Article
Closed access
YSYun Shang
Yun Shang
STSebastian Theilenberg
Sebastian Theilenberg
MTMaxim Terekhov
Maxim Terekhov
WMWolfram Mattar
Wolfram Mattar
BPBoyu Peng
Boyu Peng
CJChristoph Juchem
Christoph Juchem