23 July 2020 in Magnetic Resonance in Medicine
MSMaria Roxana Stefanescu
+5
Purpose: Inhomogeneities of the static magnetic B0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio‐temporal B0‐field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state‐of‐the‐art shimming are described, regional B0 variations are measured, and a methodology for spherical harmonics shimming of the B0 field within the human myocardium is proposed.Methods: The spatial B0‐field distribution in the heart was analyzed as well as temporal B0‐field variations in the myocardium over the cardiac cycle. Different shim region‐of‐interest selections were compared, and hardware limitations of spherical harmonics B0 shimming were evaluated by calibration‐based B0‐field modeling. The role of third‐order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase–specific shimming.Results: The strongest B0‐field inhomogeneities were observed in localized spots within the left‐ventricular and right‐ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy‐driven shim region‐of‐interest selection allowed for improved B0‐field homogeneity compared with a standard shim region‐of‐interest cuboid. Third‐order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B0‐field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase–specific shimming was performed, and a shim term‐by‐term analysis revealed periodic variations of required currents.Conclusion: Challenges in state‐of‐the‐art B0 shimming of the human heart at 7 T were described. Cardiac phase–specific shimming strategies were found to be superior to vendor‐supplied shimming.
1 August 2019 in Journal of Magnetic Resonance
16 May 2019 in IEEE Transactions on Microwave Theory and Techniques
A dedicated, novel, multichannel transmit/receive (Tx/Rx) coil array was designed, simulated, and tested for cardiac magnetic resonance imaging (cMRI) of pigs at 7 T. The cardiac array was composed of 16 elements with physically independent anterior and posterior parts. The array was connected to the MRI scanner in the parallel transmit (pTx) mode forming an 8-channel transmit and 16-channel receive (8Tx/16Rx) coil configuration. The anterior array was composed of four central octagonal elements, which were decoupled using a common central ring (CCR) and shared decoupling capacitors. The surrounding four triangular elements were decoupled from the central four elements using gaps and capacitive decoupling. In total, the eight elements of the anterior array resembled a coil with a symmetrical circular shape. Due to the advantageous arrangement of the elements in conjunction with the novel decoupling method of a CCR, the coupling between the adjacent loop elements was minimized. The posterior array was built using a 4 x 2 standard rectangular, symmetric element configuration. The dedicated cardiac array was tested in phantom and in ex vivo MR measurements with a female pig of 46 kg. The dedicated coil array enhanced the signal-to-noise ratio (40 ± 27) in ex vivo measurements of the pig heart by about three times compared to a coil prototype for cardiac human imaging (11.8 ± 7). High-resolution, ex vivo cardiac images were acquired with an in-plane resolution of up to 0.3 mm x 0.3 mm using the dedicated pig coil array. The novel cardiac array supports parallel imaging with an acceleration factor (R) of 4 without increasing the mean g-factor within the heart region beyond 1.15.
6 August 2021 in PLOS ONE
The development of novel multiple-element transmit-receive arrays is an essential factor for improving B1+ field homogeneity in cardiac MRI at ultra-high magnetic field strength (B0 > = 7.0T). One of the key steps in the design and fine-tuning of such arrays during the development process is finding the default driving phases for individual coil elements providing the best possible homogeneity of the combined B1+-field that is achievable without (or before) subject-specific B1+-adjustment in the scanner. This task is often solved by time-consuming (brute-force) or by limited efficiency optimization methods. In this work, we propose a robust technique to find phase vectors providing optimization of the B1-homogeneity in the default setup of multiple-element transceiver arrays. The key point of the described method is the pre-selection of starting vectors for the iterative solver-based search to maximize the probability of finding a global extremum for a cost function optimizing the homogeneity of a shaped B1+-field. This strategy allows for (i) drastic reduction of the computation time in comparison to a brute-force method and (ii) finding phase vectors providing a combined B1+-field with homogeneity characteristics superior to the one provided by the random-multi-start optimization approach. The method was efficiently used for optimizing the default phase settings in the in-house-built 8Tx/16Rx arrays designed for cMRI in pigs at 7T.
26 April 2022 in NMR in Biomedicine