Dongchan Lee

Dongchan Lee

Auto-generated profile, based on publicly available information

Dongchan Lee

Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2019 in IEEE Transactions on Control of Network Systems
Verified
Journal Article
Closed access
DLDongchan Lee
Dongchan Lee
Nguyen Dinh HungNguyen Dinh Hung
Nguyen Dinh Hung
KDKrishnamurthy Dvijotham
Krishnamurthy Dvijotham
KTKonstantin Turitsyn
Konstantin Turitsyn

27 April 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
DLDongchan Lee
Dongchan Lee
KTKonstantin Turitsyn
Konstantin Turitsyn
DMDaniel Molzahn
Daniel Molzahn
LRLine Roald
Line Roald
Electric power grids regularly experience uncertain fluctuations from load demands and renewables, which poses a risk of violating operational limits designed to safeguard the system. In this paper, we consider the robust AC OPF problem that minimizes the generation cost while requiring a certain level of system security in the presence of uncertainty. The robust AC OPF problem requires that the system satisfy operational limits for all uncertainty realizations within a specified uncertainty set. Guaranteeing robustness is particularly challenging due to the non-convex, nonlinear AC power flow equations, which may not always have a solution. In this work, we extend a previously developed convex restriction to a robust convex restriction , which is a convex inner approximation of the non-convex feasible region of the AC OPF problem that accounts for uncertainty in the power injections. We then use the robust convex restriction in an algorithm that obtains robust solutions to AC OPF problems by solving a sequence of convex optimization problems. We demonstrate our algorithm and its ability to control robustness versus operating cost trade-offs using PGLib test cases.

21 February 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
DLDongchan Lee
Dongchan Lee
KTKonstantin Turitsyn
Konstantin Turitsyn
DMDaniel Molzahn
Daniel Molzahn
LRLine Roald
Line Roald
Nonconvexity induced by the nonlinear AC power flow equations challenges solution algorithms for AC optimal power flow (OPF) problems. While significant research efforts have focused on reliably computing high-quality OPF solutions, it is not always clear that there exists a feasible path to reach the desired operating point. Transitioning between operating points while avoiding constraint violations can be challenging since the feasible space of the OPF problem is nonconvex and potentially disconnected. To address this problem, we propose an algorithm that computes a provably feasible path from an initial operating point to a desired operating point. Given an initial feasible point, the algorithm solves a sequence of convex quadratically constrained optimization problems over conservative convex inner approximations of the OPF feasible space. In each iteration, we obtain a new, improved operating point and a feasible transition from the operating point in the previous iteration. In addition to computing a feasible path to a known desired operating point, this algorithm can also be used to improve the operating point locally. Extensive numerical studies on a variety of test cases demonstrate the algorithm and the ability to arrive at a high-quality solution in few iterations.

1 December 2014
Verified
Conference Paper
Closed access
DLDongchan Lee
Dongchan Lee
DKDeepa Kundur
Deepa Kundur
This paper presents the detection and identification of cyber attacks in phasor measurement unit (PMU) data using the expectation-maximization algorithm. Power systems today is prone to malicious cyber attack with its greater complexity and dependence on PMUs. While the conventional power system estimation is very advanced and robust, this paper will extend the power system estimation to inherently consider the possibility of malicious cyber attack. The detection is incorporated into the estimation problem in our approach, which will be solved by the EM algorithm. The proposed algorithm is applied on an IEEE 14-bus system to illustrate the performance of the algorithm.

21 February 2019 in IEEE Transactions on Control of Network Systems
Verified
Journal Article
Closed access
DLDongchan Lee
Dongchan Lee
LALiviu Aolaritei
Liviu Aolaritei
TVThanh Long Vu
Thanh Long Vu
KTKonstantin Turitsyn
Konstantin Turitsyn
The wide deployment of renewable generation and the gradual decrease in the overall system inertia make modern power grids more vulnerable to transient instabilities and unacceptable frequency fluctuations. Time-domain simulation-based assessment of the system robustness against uncertain and stochastic disturbances is extremely time-consuming. In this paper, we develop an alternative approach, which has its roots in the input-output stability analysis for Lur'e systems. Our approach consists of a mathematically rigorous characterization of the external disturbances that the power system is transiently stable and the frequency constraints are not violated. The derived certificate is efficiently constructed via convex optimization and is shown to be nonconservative for different IEEE test cases.

15 June 2018 in IEEE Control Systems Letters
Verified
Journal Article
Closed access
LALiviu Aolaritei
Liviu Aolaritei
DLDongchan Lee
Dongchan Lee
TVThanh Long Vu
Thanh Long Vu
KTKonstantin Turitsyn
Konstantin Turitsyn
The aggressive integration of distributed renewable sources is changing the dynamics of the electric power grid in an unexpected manner. As a result, maintaining conventional performance specifications, such as transient stability, may not be sufficient to ensure its reliable operation in stressed conditions. In this paper, we introduce a novel criteria in transient stability with consideration of operational constraints over frequency deviation and angular separation. In addition, we provide a robustness measure of the region of attraction, which can quantify the ability of the post-fault system to remain synchronized even under disturbances. To assess this new stability specification, we adopt the notion of Input-to-State Stability (ISS) to the context of power systems and introduce a new class of convex Lyapunov functions, which will result in tractable convex-optimization-based stability certificates. As a result, we are able to quantify the level of disturbance a power system can withstand while maintaining its safe operation. We illustrate the introduced stability specification and certificate on the IEEE 9 bus system.