1 January 2016 in AIP Conference Proceedings
A numerical simulation to investigate the Non-Newtonian modelling effects on physiological flows in a three dimensional idealized artery with a single stenosis of 85% severity. The wall vessel is considered to be rigid. Oscillatory physiological and parabolic velocity profile has been imposed for inlet boundary condition. Where the physiological waveform is performed using a Fourier series with sixteen harmonics. The investigation has a Reynolds number range of 96 to 800. Low Reynolds number k - ω model is used as governing equation. The investigation has been carried out to characterize two Non-Newtonian constitutive equations of blood, namely, (i) Carreau and (ii) Cross models. The Newtonian model has also been investigated to study the physics of fluid. The results of Newtonian model are compared with the Non-Newtonian models. The numerical results are presented in terms of pressure, wall shear stress distributions and the streamlines contours. At early systole pressure differences between Newtonian and Non-Newtonian models are observed at pre-stenotic, throat and immediately after throat regions. In the case of wall shear stress, some differences between Newtonian and Non-Newtonian models are observed when the flows are minimum such as at early systole or diastole.
1 January 2016 in Theoretical and Applied Mechanics
A numerical simulation to investigate the Non-Newtonian modeling effects on physiological flows in a three dimensional idealized artery with a single stenosis of 85% severity is given. The wall vessel is considered to be rigid. Oscillatory physiological and parabolic velocity profile has been imposed for inlet boundary condition. Determination of the physiological waveform is performed using a Fourier series with sixteen harmonics. The investigation has a Reynolds number range of 96 to 800. Low Reynolds number k − w model is used as governing equation. The investigation has been carried out to characterize two Non-Newtonian constitutive equations of blood, namely, (i) Carreau and (ii) Cross models. The Newtonian model has also been investigated to study the physics of fluid. The results of Newtonian model are compared with the Non-Newtonian models. The numerical results are presented in terms of velocity, pressure, wall shear stress distributions and cross sectional velocities as well as the streamlines contour. At early systole pressure differences between Newtonian and Non-Newtonian models are observed at pre-stenotic, throat and immediately after throat regions. In the case of wall shear stress, some differences between Newtonian and Non-Newtonian models are observed when the flows are minimum such as at early systole or diastole. In general, the velocities at throat regions are highest at all-time phase. However, at pick systole higher velocities are observed at post-stenotic region. Downstream flow of all models creates some recirculation regions at diastole.
1 January 2015 in Procedia Engineering
11 April 2017 in Journal of Physics: Conference Series
The present study investigates the significant changes of flow behavior for 65 and 85 percentages severities of stenosis by area. The blood is assumed to be incompressible, homogeneous and Newtonian, while artery is assumed to be a rigid wall. The transient analysis is performed using ANSYS-14.5. Oscillatory physiological and parabolic velocity profile has been imposed for inlet boundary condition. The investigation has a Reynolds number range of 96 to 800. Pressure based solver and finite volume method are used for calculations. The flow pattern, wall shear stress (WSS), pressure, velocity, streamline contours, cross sectional and Centre-line velocity distribution are observed at early-systole, peak-systole and diastole for better understanding of arterial disease. Wall Shear Stress distribution shows that as severity increases, shearing of flow also increases for all cases. Thus maximum stress is exerted in throat region at peak systole. Pressure distribution also demonstrates that at all cases 85% stenotic artery creates more force than 65% stenotic artery at their pre-stenotic region. Interestingly, a recirculation region is visible at the post stenotic region in 85% stenotic artery for all cases and recirculation region increases with increasing minimum velocity at the inlet flow. From streamline contours it can be interpreted that 85% stenosis can create vortex at any time phase. So 85% stenosis is very harmful for its high probability of creating vortex.
1 January 2019 in The Proceedings of Conference of Tohoku Branch
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies