Lei Mou

Lei Mou

Auto-generated profile, based on publicly available information

Lei Mou

Laboratory of Advanced Theranostic Materials and Technology, Ningbo Institute of Materials Technology and Engineering, and Ningbo Cixi Institute of Biomedical Engineering, Chinese Academy of Sciences, Ningbo, China

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2026 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
LMLei Mou
Lei Mou
YLYonghuai Liu
Yonghuai Liu
ZXZhuoting Xu
Zhuoting Xu
HZHao Zhang
Hao Zhang
Yalin ZhengYalin Zheng
Yalin Zheng
Yifan ZhaoYifan Zhao
Yifan Zhao
Quantitative analysis of retinal vascular morphology is vital for clinical decision-making and the investigation of systemic diseases. Central to this process is the accurate segmentation of retinal arteries and veins (A/V) from the background, a task challenged by substantial variations in vessel calibers and the presence of low-contrast or ambiguous structures in fundus images, especially in ultra-wide field imaging where peripheral distortions and large-scale anatomical variability are pronounced. These factors often lead to fragmented semantic representations and topological inconsistencies in automated segmentation outputs. To address these limitations, we propose Ultra, a multi-granularity topological reasoning network designed for precise A/V segmentation. Ultra adopts a cascaded two-stage architecture: PriorNet generates coarse, multi-scale vascular priors that provide structural guidance, while RefineNet performs topology-aware segmentation refinement. To further enforce topological coherence, we propose the neighboring pixel connectivity regularization (NICER) layer, which selectively integrates local connectivity information predicted by the proposed connectivity prediction union (CPU) module. This connectivity is employed as auxiliary supervision through a pixel-wise local connectivity loss, reinforcing structural reasoning and promoting anatomically consistent vascular topology inference. Extensive experiments on ultra-wide field fundus imaging (UWF) datasets demonstrate that Ultra achieves state-of-the-art performance in A/V segmentation and topological preservation. Moreover, Ultra generalizes well to conventional color fundus photography (CFP) datasets, underscoring its robustness and broad applicability. Code is publicly available at: https://github.com/iMED-Lab/Ultra.