Marija Milosavljević

Marija Milosavljević

Auto-generated profile, based on publicly available information

Marija Milosavljević


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025
Verified
Conference Paper
Closed access
SFSrbija Univerzitet U Beogradu – Rudarsko-Geološki Fakultet
Srbija Univerzitet U Beogradu – Rudarsko-Geološki Fakultet
TĐTina Đurić
Tina Đurić
DRDragoslav Rakić
Dragoslav Rakić
JPJovana Janković Pantić
Jovana Janković Pantić
IIIrena Basarić Ikodinović
Irena Basarić Ikodinović
MMMarija Milosavljević
Marija Milosavljević
Empirical correlations commonly used in geotechnical practice can serve as a valuable tool for estimating the required parameters during the design phase and execution of geotechnical analyses. One of the increasingly important parameters in geotechnical analysis is the undrained shear strength of soil, whose use is also recommended by Eurocode 7 standards, especially when examining the properties of fine-grained soils. Variations in water content significantly influence the consistency state of the soil and have a substantial impact on its behaviour, particularly on shear strength. This study presents correlations between undrained shear strength (cu), determined using the fall cone method, and water content. The results showed a high level of correlation between undrained shear strength and water content, confirming a logarithmic relationship. Empirical equations were applied to enable more accurate estimation of undrained shear strength, with a high coefficient of determination (R²).

1 January 2025
Verified
Conference Paper
Closed access
MMMarija Milosavljević
Marija Milosavljević
DRDragoslav Rakić
Dragoslav Rakić
TĐTina Đurić
Tina Đurić
IAIvan Arsić
Ivan Arsić
NSNemanja Stanić
Nemanja Stanić
A sanitary landfill is a complex geotechnical structure for safe and environmentally sound disposal of municipal waste. To prevent environmental contamination, especially of groundwater, design solutions must ensure high impermeability, stability, and long-term protection. The landfill base is protected with a double-layer composite lining and a leachate collection system, while cover layers prevent erosion and infiltration. This study presents the „Gigoš“ Regional Sanitary Landfill in Jagodina as an example of modern landfill design. Special emphasis is placed on geosynthetic materials in lining layers for efficient impermeability and minimal environmental impact. Using project documentation and field data, the landfill layers, their functions, and their role in long-term environmental protection are analyzed.