23 May 2017 in Biotechnology and Bioengineering
The emergence of medicinal indications for stem cell therapies has seen a need to develop the manufacturing capacity for adherent cells such as mesenchymal stem cells (MSCs). One such development is in the use of microcarriers, which facilitate enhanced cell densities for adherent stem cell cultures when compared with 2D culture platforms. Given the variety of stem cell expansion systems commercially available, novel methods of non‐invasive and automated monitoring of cell number, confluence, and aggregation, within disparate environments, will become imperative to process control, ensuring reliable and consistent performance. The in situ epi‐illumination of mouse embryonic fibroblasts and human mesenchymal stem cells attached to Cytodex 1 and 3 microcarriers was achieved using a bespoke microscope. Robust image processing techniques were developed to provide quantitative measurements of confluence, aggregate recognition, and cell number, without the need for fluorescent labeling or cell detachment. Large datasets of cells counted on individual microcarriers were statistically analyzed and compared with NucleoCounter measurements, with an average difference of less than 7% observed from days 0 to 6 of a 12‐day culture noted, prior to the onset of aggregation. The developed image acquisition system and post‐processing methodologies were successfully applied to dynamically moving colonized microcarriers. The proposed system offers a novel method of cell identification at the individual level, to consistently and accurately assess viable cell number, confluence, and cell distribution, while also minimizing the variability inherent in the current invasive means by which cells adhered to microcarriers are analyzed. Biotechnol. Bioeng. 2017;114: 2032–2042. © 2017 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc.
1 January 2020 in CIRP Annals
22 November 2006 in Optics Letters
We introduce a new surface measurement method for potential online application. Compared with our previous research, the new design is a significant improvement. It also features high stability because it uses a near common-path configuration. The method should be of great benefit to advanced manufacturing, especially for quality and process control in ultraprecision manufacturing and on the production line. Proof-of-concept experiments have been successfully conducted by measuring the system repeatability and the displacements of a mirror surface.
28 February 2008 in Applied Optics
Light beam scanning using a dispersive element and wavelength tuning is coupled with fiber-optic interferometry to realize a new surface measurement instrument. The instrument is capable of measuring nanoscale surface structures and form deviations. It features active vibration compensation and a small optical probe size that may be placed remotely from the main apparatus. Active vibration compensation is provided by the multiplexing of two interferometers with near common paths. Closed loop control of a mirror mounted on a piezoelectric transducer is used to keep the path length stable. Experiments were carried out to deduce the effectiveness of the vibration compensation and the ability to carry out a real measurement in the face of large environmental disturbance.
27 April 2023 in CIRP Annals
12 July 2018 in The International Journal of Advanced Manufacturing Technology
High-angled structured surfaces such as micropyramidal arrays, V-grooves and lenslet arrays are widely used in industries. However, there is currently no effective way to inspect these microstructures, resulting in very high scrap rates. This paper presents a proof-of-principle demonstration of an optical system capable of measuring V-groove structures in a single measurement acquisition. The dual-probe wavelength scanning interferometry (DPWSI) system comprises dual probes, with orthogonal measurement planes. The calibration of the DPSWI system is the key to registering the relative locations of the dual measurement planes and allowing the surface topography to be correctly reconstructed. In order to achieve this, a custom calibration artefact was manufactured comprising focused ion beam etched features on two faces of a precision cube. The procedures for the characterisation of the artefact to generate reference topography, and the subsequent calibration of the DPWSI are described in full. A measurement example from a metallised saw tooth sample featuring near-right-angles grooves having a peak-to-valley height of 32 μm and nominal pitch of 25 μm is presented and compared with a result obtained using stylus profilometry. DPWSI is shown to obtain an areal dataset in a single acquisition and is able to better resolve peak/valley points compared with the stylus, which is limited by a 2-μm tip radius. Some lateral scale error is apparent in the final DPWSI results and a discussion of this in terms of the limitations surrounding the current calibration artefact is presented.