1 August 2020 in The Journal of Prosthetic Dentistry
15 January 2020 in Scientific Reports
Segmentation is fundamental to medical image analysis. Recent advances in fully convolutional networks has enabled automatic segmentation; however, high labeling efforts and difficulty in acquiring sufficient and high-quality training data is still a challenge. In this study, a cascaded 3D U-Net with active learning to increase training efficiency with exceedingly limited data and reduce labeling efforts is proposed. Abdominal computed tomography images of 50 kidneys were used for training. In stage I, 20 kidneys with renal cell carcinoma and four substructures were used for training by manually labelling ground truths. In stage II, 20 kidneys from the previous stage and 20 newly added kidneys were used with convolutional neural net (CNN)-corrected labelling for the newly added data. Similarly, in stage III, 50 kidneys were used. The Dice similarity coefficient was increased with the completion of each stage, and shows superior performance when compared with a recent segmentation network based on 3D U-Net. The labeling time for CNN-corrected segmentation was reduced by more than half compared to that in manual segmentation. Active learning was therefore concluded to be capable of reducing labeling efforts through CNN-corrected segmentation and increase training efficiency by iterative learning with limited data.
17 March 2020 in Scientific Reports
We quantitatively evaluated breast tumor movement and volume changes between magnetic resonance imaging (MRI) scans in prone and supine positions. Twenty-seven breast tumor patients who received neoadjuvant systemic therapy (NST) for breast-conserving surgery were studied. Before and after NST, MRI scans in prone and supine positions were performed immediately. Tumor segmentation, volume, and position of tumors were evaluated in both positions. Average tumor volumes in prone and supine positions did not significantly differ (p = 0.877). Tumor movement from prone to supine positions from the origin of the bottom center of the sternum was strongly correlated with the distance from the tumor center to the chest wall (r = 0.669; p < 0.05). Tumor changes from prone to supine positions measured from the origin of the nipple depended on the location of the tumor in the breast. The prone-to-supine movement of all tumors from the origin of the bottom center of the sternum tended to move outward from the sagittal centerline of the body on the coronal plane, to the inside of the body on the sagittal plane, and outward and downward close to the body on the axial plane, which might help in planning operations using prone MRI in supine-position breast cancer surgery.
12 March 2023 in Computer Methods and Programs in Biomedicine
16 March 2022 in Scientific Reports
1 January 2021 in SSRN Electronic Journal
Background: In thoracoabdominal aortic aneurysm repair, repairing the visceral and segmental arteries is challenging. Although there is a pre-hand-sewn and multi-branched graft based on the conventional image-based technique, it has shortcomings in precisely positioning and directing the visceral and segmental arteries. Methods: We introduce two new reconstruction techniques using patient-specific 3D-printed graft reconstruction guides: 1) model-based technique that presents the projected aortic graft, visualizing the main aortic body and its major branches and 2) guide-based technique in which the branching vessels in the visualization model are replaced by marking points identifiable by tactile sense. The graft reconstruction guides cover the segmentation, design, fabrication, post-processing, and clinical application of open surgical repair of thoracoabdominal aneurysm, and proved to be efficient for accurately reconstructing customized grafts. Findings: This study is demonstrated to the effectiveness and efficiency by evaluating conventional and new techniques with digital model. The accuracy, reproducibility, and satisfaction of the two new techniques were higher than that of the conventional technique, and the marking time requirement for graft reconstruction was reduced. Interpretation: The two new reconstruction techniques have the potential to improve outcome as they can solve anatomical hurdles for individual anatomical variation and focus on important procedures by reducing the level of fatigue of operating surgeons for lengthy and exhausting surgery. Funding Information: This study was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (HI18C2383). Declaration of Interests: The authors declare no competing interests. Ethics Approval Statement: The institutional review board for human investigations at Asan Medical Center approved this study with a waiver of informed consent from patients because of the use of retrospective clinical and imaging data. The data were de-identified, in accordance with the Health Insurance Portability and Accountability Act privacy rule.