1 January 2022 in Seminars in Thoracic and Cardiovascular Surgery
1 January 2021 in SSRN Electronic Journal
Background: In thoracoabdominal aortic aneurysm repair, repairing the visceral and segmental arteries is challenging. Although there is a pre-hand-sewn and multi-branched graft based on the conventional image-based technique, it has shortcomings in precisely positioning and directing the visceral and segmental arteries. Methods: We introduce two new reconstruction techniques using patient-specific 3D-printed graft reconstruction guides: 1) model-based technique that presents the projected aortic graft, visualizing the main aortic body and its major branches and 2) guide-based technique in which the branching vessels in the visualization model are replaced by marking points identifiable by tactile sense. The graft reconstruction guides cover the segmentation, design, fabrication, post-processing, and clinical application of open surgical repair of thoracoabdominal aneurysm, and proved to be efficient for accurately reconstructing customized grafts. Findings: This study is demonstrated to the effectiveness and efficiency by evaluating conventional and new techniques with digital model. The accuracy, reproducibility, and satisfaction of the two new techniques were higher than that of the conventional technique, and the marking time requirement for graft reconstruction was reduced. Interpretation: The two new reconstruction techniques have the potential to improve outcome as they can solve anatomical hurdles for individual anatomical variation and focus on important procedures by reducing the level of fatigue of operating surgeons for lengthy and exhausting surgery. Funding Information: This study was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (HI18C2383). Declaration of Interests: The authors declare no competing interests. Ethics Approval Statement: The institutional review board for human investigations at Asan Medical Center approved this study with a waiver of informed consent from patients because of the use of retrospective clinical and imaging data. The data were de-identified, in accordance with the Health Insurance Portability and Accountability Act privacy rule.
1 January 2023 in Journal of the Korean Society of Radiology
심장과 대혈관 기원의 원발성 종괴는 매우 드물다. 그중에서도 악성 말초신경초종은 더 드물게 보고되었다. 76세 남성에서 발견된 흉수의 원인 평가를 위해 시행한 조영증강 컴퓨터단층 촬영에서 우폐정맥과 좌심방을 침범하는 저음영의 종괴가 발견되었고 초음파상 우폐정맥에서 기인한 종괴로 의심되었다. 종괴는 수술적 절제를 통해 폐정맥 기원의 악성 말초신경초종으로 최종 진단되었다. 저자들은 국내에서 보고된 바가 없는 드문 증례인 폐정맥 기원의 원발성 악성 말초신경초종을 보고하고, 종괴가 폐정맥 기원임을 시사하는 영상의학적 소견에 대해 고찰하고자 한다. Primary masses rarely originate from the heart and great vessels, and a malignant peripheral nerve sheath tumor (MPNST) is extremely rare. A 76-year-old male with pleural effusion underwent contrast-enhanced computed tomography, which revealed a hypoattenuating mass involving the right pulmonary vein and left atrium. Ultrasonography showed that the mass originated from the right pulmonary vein. Surgical resection confirmed an MPNST that originated from the pulmonary vein. We report the first Korean case of a primary MPNST originating from the pulmonary vein. We have also described the radiologic findings suggestive of a pulmonary vein mass.
1 January 2026 in Annals of Thoracic and Cardiovascular Surgery
Donor coronary artery disease (CAD) can lead to the discard of otherwise suitable hearts, although selected focal lesions may be treated with concomitant revascularization. We report orthotopic heart transplantation in a 52-year-old man with end-stage ischemic cardiomyopathy and previous coronary artery bypass grafting using a donor heart in which coronary computed tomography angiography showed severe proximal left anterior descending artery (LAD) stenosis with calcified plaque. Before recipient cardiectomy, the recipient’s previously constructed, patent left internal mammary artery (LIMA)-to-LAD graft was carefully mobilized, preserved as an arterial conduit, and repurposed for donor-heart revascularization. After implantation, the salvaged recipient LIMA was anastomosed to the donor LAD distal to the stenosis. Transit-time flow measurement confirmed satisfactory graft function. The patient recovered uneventfully, with preserved biventricular function and angiographic LIMA–LAD patency. This case highlights the technical feasibility of reusing a pre-existing recipient LIMA graft to permit transplantation of a donor heart with focal CAD.
1 January 2025 in International Journal of Heart Failure
Lee SY, et al. Int J Heart Fail. 2025 Sep;7:e27. https://doi.org/10.36628/ijhf.2025.0051