Rehab Khalid

Rehab Khalid

Auto-generated profile, based on publicly available information

Rehab Khalid

Department of Radiology, Mass General Brigham and Harvard Medical School, Boston, Massachusetts, United States

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2025 in Journal of Applied Physiology
Verified
Journal Article
Closed access
ANAlice Nova
Alice Nova
YXYi Xin
Yi Xin
MVMarcus Victor
Marcus Victor
TGTimothy G. Gaulton
Timothy G. Gaulton
GAGlasiele C. Alcala
Glasiele C. Alcala
MCMaurizio Cereda
Maurizio Cereda
In a ventilated swine model, we isolated the mechanical effects of mass loading from those of lung injury. Despite optimization, positive end-expiratory pressure (PEEP) could not restore baseline pulmonary compliance or lung volumes in either healthy or injured lungs. Partitioned respiratory mechanics and imaging reveal that geometric constraints and load-induced airway closure, demonstrated here for the first time in injured swine, may limit the effectiveness of recruitment maneuvers and optimized PEEP in mass-loaded lungs.

25 July 2025 in British Journal of Radiology
Verified
Journal Article
Closed access
RKRehab N Khalid
Rehab N Khalid
DWDufan Wu
Dufan Wu
QSQuirin David Strotzer
Quirin David Strotzer
JPJunyoung Park
Junyoung Park
RGRajiv Gupta
Rajiv Gupta
Portable Computed Tomography (CT) scanners have revolutionized diagnostic imaging by bringing advanced imaging capabilities directly to the point of care in critical settings such as intensive care units, operating rooms, ambulances, and other resource-limited environments. Integrating portable CT into clinical workflows improves patient outcomes through immediate, on-site imaging, eliminating the risks and delays associated with intra-hospital transportation. These systems are indispensable in critical care, reducing complications and time to diagnosis while enabling timely interventions for life-threatening conditions such as intracranial hemorrhage. Portable CT scanners are also transforming prehospital care, particularly in mobile stroke units, where they facilitate rapid diagnosis and treatment of strokes. This review examines the fundamentals of portable CT technology and its transformative role in various clinical scenarios, such as ICUs and intraoperative imaging. It traces the evolution of CT from stationary energy integrating detector-based systems to portable photon counting detector-based systems, highlighting the advantages of this technological transition. Key benefits include reduced patient complications, enhanced spatial resolution, improved diagnostic accuracy, lower radiation doses, and superior material differentiation, illustrated through clinical examples. As innovation advances in detector design and artificial intelligence, portable CT scanners are expected to grow further, expanding their clinical applications and solidifying their role as essential tools in modern diagnostic radiology.

25 August 2025 in Radiology Case Reports
Verified
Journal Article
Open access
RKRehab N. Khalid
Rehab N. Khalid
AKAmin Khan
Amin Khan
RHRavikumar Hanumaiah
Ravikumar Hanumaiah
Acute gastric volvulus is an extremely rare but possibly lethal condition within the pediatric population and is defined by the abnormal rotation of the stomach that can lead to serious complications like ischemia, perforation, or splenic involvement if not promptly diagnosed and managed. We report the case of a 2-year-old male with a history of Chromosome Alignment-Maintaining Phosphoprotein 1 (CHAMP1) mutation and prior gastric ulcers who presented with hematemesis, retching, and feeding intolerance. Abdominal radiograph showed nonspecific dilation of the gastric bubble, and contrast-enhanced computed tomography (CT) confirmed mesentero-axial volvulus with splenic displacement. The patient underwent successful nasogastric decompression followed by laparotomy, gastric detorsion, and percutaneous endoscopic gastrostomy tube placement. This case emphasizes the role of early imaging, particularly CT, in diagnosing pediatric gastric volvulus and suggests a potential link between CHAMP1-associated hypotonia and volvulus. Timely recognition and intervention are essential for favorable outcomes in such rare pediatric emergencies.

7 July 2026 in Journal of Applied Physiology
Verified
Journal Article
Open access
ARAndrea Restivo
Andrea Restivo
MVMichele Delle Vergini
Michele Delle Vergini
GMGenevieve McCormack
Genevieve McCormack
TGTimothy G. Gaulton
Timothy G. Gaulton
GAGlasiele Alcala
Glasiele Alcala
MCMaurizio Cereda
Maurizio Cereda
Tidal changes in esophageal pressure (ΔPes) are used as a surrogate for pleural pressure changes (ΔPpl) to assess chest wall mechanics. The Baydur ratio evaluates pressure transmission and guides catheter positioning. The effects of correcting ΔPes using the Baydur ratio on the accuracy of ΔPpl estimation and its dependence on ventilation mode, spontaneous inspiratory effort, and body position, remain unclear. In ten pigs, ΔPpl was measured using intrapleural balloon catheters, while Pes was recorded at three esophageal locations in supine and prone positions. Animals underwent controlled and assisted ventilation. Baydur ratios were derived during assisted ventilation and from external chest compressions during controlled ventilation. ΔPes before and after correction was compared with ΔPpl using mixed-effects models and Bland–Altman analysis. Additionally, we quantified the proportion of values with (ΔPes−ΔPpl) ≤ 1 cmH₂O. During assisted ventilation, ΔPes showed good agreement with posterior ΔPpl. Baydur correction improved scaling and association (slope 0.76 vs 0.50; r 0.81 vs 0.79, p<0.01) and increased values within ±1 cmH₂O from 29% to 45% when the Baydur ratio fell outside the accepted range. During controlled ventilation, ΔPes showed weaker association and wider limits of agreement, without improvement after correction. Similar patterns were observed in prone position. ΔPes more accurately reflected posterior ΔPpl during assisted ventilation. Baydur correction improves scaling and association, particularly when the Baydur ratio falls outside the accepted range, but does not improve and may worsen agreement during controlled ventilation.