11 October 2023 in IEEE Sensors Journal
This paper presents an optical fiber vibration sensor with a wide detection range based on the Mach-Zehnder interference principle, which is composed of single-mode fiber (SMF), two-mode step index fiber (TMSIF), and dispersion-compensated fiber (DCF) fused, and the optical fiber sensing structure fused is SMF-TMSIF-DCF-SMF, abbreviated as STDS sensor. In this work, the single-frequency response and dual-frequency response of this sensor are tested, and the test results indicate that the sensor can stably measure the extended single-frequency response in the range of 1-23000 Hz (the maximum signal-to-noise ratio is 61.2 dB) and the dual-frequency response. In addition, the amplitude-frequency response test results reveal a good linear relationship between the fast Fourier transform amplitude and the vibration amplitude. Subsequently, a temperature test was performed on the sensor in the range of 25-65°C, and it was found that the spectral intensity shift induced by temperature was only 0.03501 dB/°C, and the measured frequency was consistent with the applied frequency. Finally, the stability and repeatability tests were carried out on the sensor, the stability test results proved that the sensor measured consistently and without deviations for 60 min, and the repeatability test proved that the sensor could measure consistently for more than 40 days and the measurement results are accurate. The sensor has the advantages of a wide detection range (the frequency measurement range is 1-23000 Hz), excellent anti-interference to temperature fluctuations, reusability, etc., and has great application prospects in various vibration signal monitoring.
12 September 2024 in IEEE Sensors Journal
Breathing is an important physiological indicator of human health. In this paper, a wearable compact single mode-no core-single mode fiber (SNCS) optical microvibration sensor based breathing monitoring system is proposed. Firstly, piezoelectric vibration experiments were conducted, focusing on low-frequency signals to verify the feasibility of optical fiber microvibration sensor for breathing monitoring, and measured frequencies reached to 0.1Hz. The piezoelectric vibration frequency is fitted to the measured frequency with a slope of 0.99772 and correlation of 0.99879. Multi-point wearable breathing monitoring experiments on the nose and abdomen were conducted. It is demonstrated that breathing states could be identified by details such as respiratory rate, exhale and inhale time between three normal and four irregular breathing states. Real-time and precise breath detection are ensured by the quick response time (0.11s) and recovery time (0.14s) of the sensor. The proposed sensor is repeatable, responsive, comfortable to wear, recognises different breathing states, and can be used for prediction of obstructive sleep apnea (OSA) syndrome and post-treatment rehabilitation monitoring, which has a promising medical application.