12 September 2024 in IEEE Sensors Journal
Breathing is an important physiological indicator of human health. In this paper, a wearable compact single mode-no core-single mode fiber (SNCS) optical microvibration sensor based breathing monitoring system is proposed. Firstly, piezoelectric vibration experiments were conducted, focusing on low-frequency signals to verify the feasibility of optical fiber microvibration sensor for breathing monitoring, and measured frequencies reached to 0.1Hz. The piezoelectric vibration frequency is fitted to the measured frequency with a slope of 0.99772 and correlation of 0.99879. Multi-point wearable breathing monitoring experiments on the nose and abdomen were conducted. It is demonstrated that breathing states could be identified by details such as respiratory rate, exhale and inhale time between three normal and four irregular breathing states. Real-time and precise breath detection are ensured by the quick response time (0.11s) and recovery time (0.14s) of the sensor. The proposed sensor is repeatable, responsive, comfortable to wear, recognises different breathing states, and can be used for prediction of obstructive sleep apnea (OSA) syndrome and post-treatment rehabilitation monitoring, which has a promising medical application.
16 October 2024 in Journal of Lightwave Technology
We propose a macroscopic loss-based olive-shaped single-mode fiber (OSSMF) for displacement sensing in the fiber loop ring-down, which validates the feasibility of displacement sensing. In this work, two systems consisting of single-point and multi-point displacement sensing are built, and the ring-down curves are demodulated using low-cost microcontroller unit and self-developed optical time domain reflectometer (OTDR), respectively. The long-cavity system is initially utilized for single-point displacement sensing to confirm the possibility of multi-point displacement detection with short cavities. The relationship between cavity length and sampling frequency is also discussed, enabling low-frequency, high-precision sampling of the ring-down curve. In the short-cavity multi-point experimental system, different sizes of olive-shaped sensing heads are compared in a 65 m cavity length scenario. It is concluded that the OSSMF with a short axis of 2.1 cm and a long axis of 3.5 cm exhibited the highest sensitivity. The attenuation is −2.11 dB/ (km mm) in the 8--12 mm range and −7.24 dB/ (km mm) in the 12--24 mm range. The displacements are detected in 65 and 125 m fiber loop ring-down (FLRD) cavities, and the ring-down curves are processed using Fast Fourier Transform, this method addresses the issue in multi-point measurements where an extension cord is needed for time-domain differentiation. Different cavity length designs enable distributed measurements of physical quantities, the system is of great significance in the fields of structural engineering monitoring and geological disaster monitoring.