Kais Abdulmawjood

Kais Abdulmawjood

Auto-generated profile, based on publicly available information

Kais Abdulmawjood

Electrical and Computer Engineering Department, Texas AM University at Qatar, Doha, Qatar

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in IEEE Access
Verified
Journal Article
Open access
KAKais Abdulmawjood
Kais Abdulmawjood
Samer Yassin AlsadiSamer Yassin Alsadi
Samer Yassin Alsadi
Shady S. RefaatShady S. Refaat
Shady S. Refaat
WMWalid G. Morsi
Walid G. Morsi
Photovoltaic (PV) systems are frequently exposed to partial or complete shading phenomena. Partial shading has a profound impact on the performance of solar power generation. The operational performance of PV arrays under partial shading shows multiple maximum power point peaks, therefore it is challenging to identify the actual maximum power point. This paper investigates the impact of partial shading location on the output power of solar photovoltaic arrays with various configurations. Multiple photovoltaic strings, in both parallel and series configurations, are considered. Different random shading patterns are considered and analyzed to determine which configuration has higher maximum power point. The sensitivity of the partial shading can change according to the partial shading types, shading pattern, and the configuration used to connect all PV modules. Moreover, the study also investigates the output of the PV array with shading two random models, two consecutive models, and three random and consecutive modules. Experimental results validate the analysis and demonstrate the effect of various partial shading on the eficiency and performance of the PV system.

14 February 2023 in IEEE Access
Verified
Journal Article
Open access
Tareq Husam FoqhaTareq Husam Foqha
Tareq Husam Foqha
Samer Yassin AlsadiSamer Yassin Alsadi
Samer Yassin Alsadi
Shady S. RefaatShady S. Refaat
Shady S. Refaat
KAKais Abdulmawjood
Kais Abdulmawjood
Electric power transmission networks should be operated in efficient, safe, and reliable conditions. To improve the stability and transfer capability of power transmission, it is necessary to mitigate the Ferranti effect. This paper investigates the impact of increasing the length of the transmission line on its receiving end voltage under no-load conditions. A variable shunt reactor compensation for transmission lines is used to control the voltage level at different lengths of the transmission line. The proposed method demonstrates that the value of the shunt reactor required to maintain the receiving end voltage can be estimated. Moreover, the system is modeled using the PowerWorld simulator, and the effectiveness of the proposed model has been verified by experimental results. The experimental results demonstrate the efficiency of the proposed methodology and match the simulation results, which are then validated by simulating the WSCC 9-bus and IEEE 30-bus test systems.