Mu Lin

Mu Lin

Auto-generated profile, based on publicly available information

Mu Lin

State Grid Sichuan Electric Power Research Institute Chengdu China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2023 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
ZLZheng Li
Zheng Li
Kai LiuKai Liu
Kai Liu
MLMu Lin
Mu Lin
DXDongli Xin
Dongli Xin
HTHao Tang
Hao Tang
GWGuangning Wu
Guangning Wu
The valve‐side bushing of the UHV converter transformer is the key equipment in the DC transmission project, and its running state directly affects the security and stability of the power system. This paper analyses the attributes of the physical entities, uses the digital twins to establish the state feature set and proposes a zero‐sample state evaluation algorithm for the valve‐side bushing. First, the geometric, materials and electrical characteristics are analyzed, and the detailed components of carrier current are obtained by empirical mode decomposition. Then, COMSOL is used to establish digital twins, verify the validity of twins with axial heat distribution of bushing, and establish a state feature set with the extreme temperature inside and outside bushing. Finally, the fuzzy clustering algorithm is used to classify the state feature set, and the similarity is used as the index to realize the zero‐sample state evaluation of the valve‐side bushing. Through the demonstration and analysis of examples, the evaluation model solves the problems of difficulty in extracting the internal features, fewer fault samples, and training difficulty, which is conducive to improving the operation and maintenance management level of power transmission equipment.

1 April 2023
Verified
Conference Paper
Closed access
HCHuarun Cheng
Huarun Cheng
Kai LiuKai Liu
Kai Liu
MLMu Lin
Mu Lin
ZDZhen Ding
Zhen Ding
HTHao Tang
Hao Tang
GWGuangning Wu
Guangning Wu
The valve-side bushing of the UHV converter transformer is one of the key pieces of equipment in the DC transmission projects, which has been bearing the high voltage and large current of the system during long-term operation. As the most commonly used electrical contact element in the valve-side bushing of the UHV converter, the contact strips are prone to deterioration and failure in the harsh operating environment. In this paper, taking the actual fault of the contact strips at the valve-side bushing of a transformer in a UHV converter station in 2021 as an example, the corrosion characteristics of the contact strips in the valve-side bushings were investigated by scanning electron microscope (SEM), energy dispersive spectrometer (EDS), X-ray diffractometer (XRD), and the microscopic changes of corrosion products during the corrosion deterioration of the contact strips were observed, and the element distribution and main components of the corrosion layer were determined. Through the contact resistance comparison experiment of the contact strips with and without the corrosion layer, the influence of corrosion on the contact performance of the contact strip was studied.

1 January 2025 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
HZHua Zhang
Hua Zhang
XSXueneng Su
Xueneng Su
YGYiwen Gao
Yiwen Gao
XNXin Ning
Xin Ning
JSJinhao Shen
Jinhao Shen
MLMu Lin
Mu Lin
Single‐phase ground faults in forest and grassland distribution networks pose a risk of igniting wildfires, necessitating enhanced fault detection and handling. However, the transitional resistance of faults such as tree‐line faults is generally high, and the current mainstream fault detection technologies for ground faults lack sufficient high‐resistance detection capability, which is inadequate for wildfire prevention scenarios. This paper proposes a high‐sensitivity ground fault detection method based on zero‐sequence voltage, which can enhance the high‐resistance detection capability up to 100 kΩ. By analysing the general characteristics of ground faults in distribution networks, the relationship between fault features and system network parameters is revealed. The structural characteristics of distribution networks in forest and grassland areas are summarised, and a method for actively enhancing fault zero‐sequence voltage signals is proposed. Based on zero‐sequence voltage, a high‐sensitivity ground startup is constructed and methods for achieving startup sensitivity, reliability and selectivity are explained. Finally, the performance of the proposed method is validated through simulations and field application cases.