Rafael Massunari Maenosono

Rafael Massunari Maenosono

Auto-generated profile, based on publicly available information

Rafael Massunari Maenosono

Fundacao Municipal de Educação e Cultura

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
MVMarilia Velo
Marilia Velo
LWLinda Wang
Linda Wang
AFAdilson Yoshio Furuse
Adilson Yoshio Furuse
LBLetícia Ferreira de Freitas Brianezzi
Letícia Ferreira de Freitas Brianezzi
CSCassiana Koch Scotti
Cassiana Koch Scotti
RMRafael Francisco Lia Mondelli
Rafael Francisco Lia Mondelli
This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey’s HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.

10 December 2018 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
GZGiovanna Speranza Zabeu
Giovanna Speranza Zabeu
RMRafael Massunari Maenossono
Rafael Massunari Maenossono
CSCaren Roberta Scarcella
Caren Roberta Scarcella
LBLetícia Ferreira Freitas Brianezzi
Letícia Ferreira Freitas Brianezzi
RPRegina Guenka Palma-Dibb
Regina Guenka Palma-Dibb
SISérgio Kiyoshi Ishikiriama
Sérgio Kiyoshi Ishikiriama
Keywords: Dentin bonding agents; Lasers; Tensile strength

2 March 2021 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
CMChristine Men Martins
Christine Men Martins
PLPriscila Bruna Gonçalves Lacerda
Priscila Bruna Gonçalves Lacerda
RMRafael Massunari Maenosono
Rafael Massunari Maenosono
ACAnderson Catelan
Anderson Catelan
VBVictor Eduardo De Souza Batista
Victor Eduardo De Souza Batista
Dentist community needs to understand the esthetic perception of laypeople and correlate the standards of dental esthetics to avoid unnecessary treatment. Thus, the aim was to compare the perception of smile attractiveness before and after performing esthetic dental procedures by general practitioners (GP), periodontists (P), restorative dentistry (RD), undergraduate students (UGrad), and laypeople (L). Two photographs of smile were taken, before (PSB) and after (PSA) the esthetic dental procedures. Photographs were exposed to 5 groups: GP (n = 20), P (n = 20), RD (n = 20), UGrad (n = 60), and L (n = 20). The smiles were evaluated using the visual scale with scores ranging from 1 (unattractive) to 10 (very attractive). Data were statistically evaluated (Kruskal-Wallis, Dunn, Mann Whitney). The PSA of the esthetic dental procedures was more attractive than PSB (p < 0.05). In PSB, P group presented the lowest values of smile attractiveness scores (p < 0.05). On the other hand, in PSA, RD group attributed lower values (p < 0.05). The perception of smile attractiveness after performing dental procedures was higher than before, and P and RD were more critical in evaluating the smiles before and after treatment, respectively.

27 February 2015 in Brazilian Dental Science
Verified
Journal Article
Open access
PDF file
SISérgio Kiyoshi Ishikiriama
Sérgio Kiyoshi Ishikiriama
RMRafael Massunari Maenosono
Rafael Massunari Maenosono
LBLetícia Ferreira de Freitas Brianezzi
Letícia Ferreira de Freitas Brianezzi
VCVanessa Maira Vieira Cunha
Vanessa Maira Vieira Cunha
RMRafael Francisco Lia Mondelli
Rafael Francisco Lia Mondelli
Objective: Neodymium (Nd:YAG) and Diode LASER irradiation on adhesive systems canincrease bond strength to dentin, however, concerns about the temperature variation inside pulp chamber still remain. The aim of this study was to evaluate the intra pulp chamber temperature variation caused by irradiation with Nd:YAG or Diode LASER on different adhesive systems. Material and Methods: This study presented experimental design with two factors: LASER on two levels (Diode [D] and Nd:YAG [N]) and adhesive system on four levels (Adper™ Scotchbond™ Multi-Purpose [MP], Adper™ SingleBond 2 [SB], Clearfil™ SE Bond [CSE] and Adper™ Easy One [EO]). The quantitative response variable was the temperature variation (Δt) in C. Forty bovine teeth, distributed into 8 groups (n = 5), had the buccal surface flattened up to1 mm thickness of dentin. After the application of each adhesive system, but previously to the light curing, specimens were irradiated with Nd:YAG or Diode LASER with standardized parameters. The Δt was obtained through a thermocouple inserted into pulp chamber. The values of Δt were submitted to two-way ANOVA, followed by Tukey (p < 0.05) for individual comparisons. Results: The means (± standard deviation) of Δt were: N-MP: 12.60 (± 2.51), N-SB: 10.40 (± 5.03), N-CSE: 11.80 (± 5.12) and N-EO: 10.20 (± 2.39), D-MP: 4.4 (± 1.82), D-SB: 5.20 (± 1.54), D-CSE: 4.60 (± 1.14), D-EO: 3.60 (± 1.52). Conclusion: The type of adhesive system was not significant in temperature changes generated by LASER irradiation, but Nd:YAG LASER may provide a higher potential to cause pulp damage.

2 March 2026 in UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR
Verified
Journal Article
Open access
PDF file
RMRafael Massunari Maenosono
Rafael Massunari Maenosono
GRGustavo Henrique Martins Rotulo
Gustavo Henrique Martins Rotulo
JSJuliana Casalino Amorim Silva
Juliana Casalino Amorim Silva
SPSelene Paiva Paraguassu
Selene Paiva Paraguassu
VRVictor Hugo Ribeiro e Rosa
Victor Hugo Ribeiro e Rosa
SISérgio Kiyoshi Ishikiriama
Sérgio Kiyoshi Ishikiriama
Considerando que a diversidade de formulações comerciais e de sistemas fotoiniciadores pode alterar o desempenho das resinas compostas frente a diferentes protocolos de fotoativação, este estudo teve como objetivo avaliar a microdureza Knoop de cinco resinas compostas fotoativadas com aparelhos fotopolimerizadores monowave e polywave. Metodologia: Espécimes com 10 mm de diâmetro e 2 mm de espessura (n = 10) das resinas Filtek Z350 XT (3M ESPE), Vittra APS (FGM Dental), Spectra Smart (Dentsply Sirona), Forma (Ultradent Products) e Palfique LX5 (Tokuyama Dental) foram fotoativados por 40 s com um aparelho monowave (LED azul; 1000 mW/cm²) ou polywave (LED azul-violeta; 1200 mW/cm²). Após armazenamento em água destilada por 24 h e polimento, foram realizadas três indentações Knoop por espécime (0,49 N; 15 s). Os dados foram analisados por ANOVA a dois fatores e teste de Tukey (α = 0,05). Resultados: A Vittra APS apresentou os maiores valores de microdureza (135 KHN com o aparelho monowave e 125 KHN com o polywave), seguida pela Filtek Z350 XT (106–107 KHN). Spectra Smart, Forma e Palfique LX5 apresentaram os menores valores (94–98 KHN), sem diferença estatística entre si. A fotoativação polywave reduziu a microdureza da Vittra APS e aumentou a da Palfique LX5 (p < 0,05); para as demais resinas, não houve diferença entre os aparelhos. Conclusão: O efeito do aparelho fotopolimerizador sobre a microdureza Knoop foi material-dependente. Independentemente da combinação entre resina composta e aparelho, todos os grupos apresentaram valores satisfatórios de microdureza. SURFACE HARDNESS OF COMPOSITE RESINS LIGHT-CURED WITH MONOWAVE AND POLYWAVE LIGHT-CURING UNITS ABSTRACT Considering that the diversity of commercial formulations and photoinitiator systems may affect the performance of composite resins under different light-curing protocols, this study aimed to evaluate the Knoop microhardness of five composite resins light-cured using monowave and polywave light-curing units. Methods: Specimens measuring 10 mm in diameter and 2 mm in thickness (n = 10) were prepared from Filtek Z350 XT (3M ESPE), Vittra APS (FGM Dental), Spectra Smart (Dentsply Sirona), Forma (Ultradent Products), and Palfique LX5 (Tokuyama Dental) composite resins. The specimens were light-cured for 40 s using either a monowave unit (blue LED; 1,000 mW/cm²) or a polywave unit (blue-violet LED; 1,200 mW/cm²). After storage in distilled water for 24 h and polishing, three Knoop indentations were performed on each specimen (0.49 N; 15 s). Data were analyzed using two-way analysis of variance (ANOVA) and Tukey's test (α = 0.05). Results: Vittra APS exhibited the highest microhardness values (135 KHN with the monowave unit and 125 KHN with the polywave unit), followed by Filtek Z350 XT (106–107 KHN). Spectra Smart, Forma, and Palfique LX5 exhibited the lowest values (94–98 KHN), with no statistically significant differences among them. Polywave light-curing reduced the microhardness of Vittra APS and increased that of Palfique LX5 (p < 0.05); no differences between the light-curing units were observed for the other composite resins. Conclusion: The effect of the light-curing unit on Knoop microhardness was material-dependent. Regardless of the combination of composite resin and light-curing unit, all groups exhibited satisfactory microhardness values.