As buckling-restrained braced frames (BRBFs) have been used increasingly in the United States, the need for knowledge about BRBF behavior has grown. In particular, large-scale experimental evaluations of BRBFs are necessary to demonstrate the seismic performance of the system. Although tests of buckling-restrained braces (BRBs) have demonstrated their ability to withstand significant ductility demands, large-scale BRBF tests have exhibited poor performance at story drifts between 0.02 and 0.025 rad . These tests indicate that the large stiffness of the typical beam-column-brace connection detail leads to large flexural demands that cause undesirable failure modes. As part of a research program composed of numerical and experimental simulations, a large-scale BRBF with improved connection details was tested at the ATLSS Center, Lehigh University. During multiple earthquake simulations, which were conducted using a hybrid pseudodynamic testing method, the test frame sustained story drifts of close to 0.05 r...
1 September 2007 in Journal of Structural Engineering
As the use of buckling-restrained braced frames (BRBFs) has increased in the United States, the need has grown for knowledge about member and system behavior under seismic loads and for implementing this knowledge into design provisions. In particular, methods for designing BRBFs and predicting seismic response require validation. To address this need, along with the need for experiments demonstrating system-level BRBF performance, a research program composed of numerical and large-scale experimental simulations was initiated at the ATLSS Center, Lehigh University. This paper describes the nonlinear dynamic analyses that were conducted as part of this research program. Numerical simulations of BRBF response were conducted using ground motion records scaled to two seismic hazard levels. The performance of the prototype BRBF was acceptable and performance objectives were met in terms of structural damage. It is shown that the currently accepted deflection amplification factor underestimates mean inelastic l...
1 October 2017 in Journal of Structural Engineering
Mass timber is an attractive and sustainable alternative structural engineering material to concrete and steel. Despite successful midrise to high-rise timber building projects around the world, such buildings have not been implemented in regions with high seismicity due in part to a lack of research and development on appropriate ductile seismic load resisting systems for heavy timber construction. This paper describes experiments conducted to develop a resilient lateral force-resisting wall system that combines cross-laminated timber (CLT) panels with vertical posttensioning (PT) to provide postevent recentering. Supplemental mild steel U-shaped flexural plate (UFPs) are intended to yield under cyclic loading while the PT and CLT components remain undamaged until large interstory drifts are experienced by the wall. The experiments were designed to explore various limit states for self-centering CLT (SC-CLT) walls, including their dependence on design variables and their effect on performance, and to investigate strength and stiffness degradation at large interstory drifts. It was found that the SC-CLT walls were able to recenter even after large drift cycles and the crushing of the CLT material was the governing limit state for most specimens. A hierarchy of desirable limit states was identified consisting of UFP yielding, CLT splitting, PT yielding, and CLT crushing.
A cross-laminated timber (CLT) panel is a heavy timber structural component fabricated by laminating layers of timber boards in an orthogonal pattern. This paper presents a study of the lateral-load response of self-centering (SC) posttensioned CLT structural walls (i.e., SC-CLT walls), which are constructed by posttensioning CLT wall panels to the foundation with vertical posttensioning steel bars. The bars pass through the CLT panels and are anchored to the CLT panels at the top of the wall and to the foundation at the bottom of the wall. Cyclic loading tests were conducted on a series of SC-CLT wall specimens with different configurations. Structural limit states of SC-CLT walls under lateral load are identified. Two types of analytical models are proposed to predict SC-CLT wall response, namely, a design-oriented analytical model based on simple mathematical expressions, and a fiber-element-based numerical model. Comparisons between the analytical and experimental results are made, which indicate that the simple mathematical expressions and the fiber-element-based numerical model provide accurate estimates of the lateral-load response of SC-CLT walls under cyclic loading.
Bridge performance undergoes time-varying changes when exposed to aggressive environments. While much work has been done on bridge reliability under corrosion, little is known about the effects of creep and shrinkage on the reliability of concrete bridges. In this paper, the CEB-FIP model for creep and shrinkage is applied by using finite-element (FE) analysis in conjunction with probabilistic considerations. Verification is made by comparing the analytical findings with existing test data. More specifically, a time-dependent reliability assessment is made for a composite prestressed concrete (PSC) box-girder bridge exposed to a chloride environment. This realized via an advanced probabilistic FE method. The postcracking behavior of the thin-walled box girder is described using composite degenerated shell elements, and importance sampling is used to improve the efficiency of the reliability analyses. It is shown that concrete creep and shrinkage dominate during the early stages of bridge structure deterio...
This paper presents an experimental study of a 0.6-scale 2-bay 4-story steel self-centering moment-resisting frame (SC-MRF) test structure under maximum considered earthquake (MCE) ground motions. A SC-MRF uses high-strength posttensioning (PT) strands to precompress the beams to the columns and to close the gaps between the beam flanges and column flanges that occur at the beam-column interface under earthquake loading, returning the frame to its initial position (i.e., the frame is self-centering). In this study, a beam web friction device is included in each beam-column connection to dissipate energy under seismic loading. The SC-MRF design objectives are to be without structural damage, creating the potential for immediate occupancy performance under the design basis earthquake, and to suffer only modest damage, leading to collapse prevention (CP) performance under the MCE. The CP performance is achieved by avoiding beam web buckling and PT strand yielding and fracture. A special fuse that pre...