Maria Goreti R. Vale

Maria Goreti R. Vale

Auto-generated profile, based on publicly available information

Maria Goreti R. Vale

Universidade Federal do Rio Grande do Sul

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2006 in Analytica Chimica Acta
Verified
Journal Article
Closed access
FLFábio G. Lepri
Fábio G. Lepri
BWBernhard Welz
Bernhard Welz
DBDaniel Borges
Daniel Borges
ASAlessandra F. Silva
Alessandra F. Silva
MVMaria Goreti R. Vale
Maria Goreti R. Vale
UHUwe Heitmann
Uwe Heitmann

1 January 2016 in Talanta
Verified
Journal Article
Closed access
ÁDÁlvaro T. Duarte
Álvaro T. Duarte
ABAline R. Borges
Aline R. Borges
AZAriane V. Zmozinski
Ariane V. Zmozinski
MDMorgana B. Dessuy
Morgana B. Dessuy
BWBernhard Welz
Bernhard Welz
MVMaria Goreti R. Vale
Maria Goreti R. Vale

1 July 2017 in Microchemical Journal
Verified
Journal Article
Closed access
MPMarianna Pozzatti
Marianna Pozzatti
FNFlávio V. Nakadi
Flávio V. Nakadi
MVMaria Goreti R. Vale
Maria Goreti R. Vale
BWBernhard Welz
Bernhard Welz

26 February 2019 in Food Analytical Methods
Verified
Journal Article
Closed access
PDF file
RGRaimundo R. Gamela
Raimundo R. Gamela
EBEliana G. Barrera
Eliana G. Barrera
ÁDÁlvaro T. Duarte
Álvaro T. Duarte
WBWiliam Boschetti
Wiliam Boschetti
MSMárcia Messias Silva
Márcia Messias Silva
MDMorgana B. Dessuy
Morgana B. Dessuy

20 April 2016 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
WBW. Boschetti
W. Boschetti
MOM. Orlando
M. Orlando
MDM. Dullius
M. Dullius
MDM. B. Dessuy
M. B. Dessuy
MVM. G. R. Vale
M. G. R. Vale
JAJailson Bittencourt de Andrade
Jailson Bittencourt de Andrade
An analytical method has been developed for the sequential and simultaneous determination of Cd, Cr, Fe and Al (via the AlH molecule) in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry and direct solid sample analysis. First, Cd (228.802 nm) was determined using 800 °C and 1700 °C as the pyrolysis and atomization temperatures, respectively. Subsequently, after changing the wavelength, Cr (425.433 nm), Fe (425.076 nm) and Al (425.315 nm) were determined simultaneously from the same sample aliquot using 2600 °C as the atomization (Cr and Fe) or vaporization (AlH) temperature. Al determination was carried out using the diatomic molecule AlH without adding a molecule-forming reagent. The interference caused by Al in Cd determination was minimized by using 10 μL of a 10% v/v H2SO4 solution in all measurements. Aqueous standard solutions were used for calibration and the limits of detection and quantification obtained were 7.3 and 24 pg mg−1 for Cd, 0.13 and 0.45 ng mg−1 for Cr, 0.07 and 0.23 μg mg−1 for Fe and 0.42 and 1.4 μg mg−1 for Al, respectively. The concentration values for Cd, Cr, Fe and Al obtained from the soil certified reference material (CRM) Montana Soil I (NIST SRM 2710a) analysis were in agreement with the reported ones. The precision of the measurements, expressed as the relative standard deviation, was better than 10%. Six soil samples from a vineyard field were investigated and the results are in accordance with the Brazilian legislation.

28 December 2006 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
FDFábio De Souza Dias
Fábio De Souza Dias
WSWalter N. L. dos Santos
Walter N. L. dos Santos
ACAntônio C. S. Costa
Antônio C. S. Costa
BWBernhard Welz
Bernhard Welz
MVMaria Goreti R. Vale
Maria Goreti R. Vale
SFSergio Luis Costa Ferreira
Sergio Luis Costa Ferreira