21 November 2023 in IEEE Access
The increasing switching frequency of inverters in new electric power technology causes leakage currents at tens or even hundreds of kHz, exceeding the measurement frequency range of conventional AC residual current sensors. In addition, the cost of residual current sensors developed specifically for DC is high, limiting further application promotion. Hence, this paper focuses on designing a wideband closed-loop residual current sensor based on self-excited oscillation fluxgate, which outperforms ordinary measurement methods. The sensor is developed through the optimization of demodulation circuits, and the increase of AC windings and the construction of excitation voltage regulating circuits. The DC residual current measurement accuracy of the sensor is better than 0.2%. The standard deviation of zero-point change is 0.0046 mA. The introduction of this innovative sensor not only enables precise and stable measurement of residual currents but also facilitates current monitoring in high-frequency applications. It can be fully applied in the field of power technology and will promote the development of efficient and reliable power systems.
16 December 2020 in IEEE Transactions on Instrumentation and Measurement
During the impulse voltage comparison test, it is important to keep the waveforms smooth for obtaining consistent experiment results, especially for the front time parameter. However, steps or oscillations are often found on the front of the waveforms. The authors propose a theory that these oscillations can be caused by the resistors in the damped capacitive voltage divider, which often serves as the load capacitor in the impulse voltage generation circuit. The theoretical analysis, numerical simulation, and experimental results are performed, and a good agreement has been found in support of the proposed theory. Furthermore, the waveform parameters measured by two resistive reference standard systems were found to be influenced by the shape of the waveform and the oscillation on the front. It is recommended to avoid using a damped capacitive divider as the load capacitor but use an impulse capacitor with low equivalent series resistance instead. This would help to eliminate this common cause of oscillation on the front of the lightning impulse voltage waveform. Waveform uniformity and uncertainty of the result could then be improved during the comparison of reference measuring systems.
7 February 2020 in IEEE Access
The series summation method is an important method in the calibration of the voltage coefficient (VC) of the standard voltage transformers (VTs), in which the key step is connecting a fullyinsulated VT and a semi-insulated VT in series, and comparing them with the third VT under test. Caused by the imperfect electrical shielding of the serially-wound VTs, additional errors are introduced in the calibration. By analyzing the cause of the additional errors in the serial connection of the VTs, two methods were designed in this paper to measure the additional errors. The proposed methods were harnessed to measure the additional errors for a serial connection of a 35 kV fully-insulated two-stage voltage transformer (TSVT) and a 35 kV semi-insulated TSVT. The results show that the two methods give a consistency of better than 1.0×10-6 in ratio error and 2.0 μrad in phase displacement, respectively. The accurate measurement of the series additional errors and the correction of them significantly improve the accuracy of the VC measurement of a 110 / √3 kV TSVT based on the series summation method. Furthermore, the VC measurement result is verified by the consistency of the series summation method with the series additional errors corrected and the high-voltage standard capacitor method.
21 July 2022 in IEEE Transactions on Instrumentation and Measurement
High-voltage compressed-gas capacitor is a type of precision equipment commonly used in high-voltage laboratories. The voltage dependence of capacitance, in other words, the voltage coefficient (VC) of capacitance, is an important factor to ensure the measurement accuracy of capacitors. The simplified tilting method (STM) derived from PTB, which provides a solution for measuring the VC of the high-voltage capacitor with compressed-gas coaxial cylindrical electrodes structure. However, it is not an easy work for most laboratories. In order to evaluate the VC based on the STM, a special experimental platform was developed. The high-voltage capacitor installed on the platform can be tilted and rotated at high voltage and can be remote-controlled. Based on the developed platform, the VC of a 350-kV high-voltage capacitor was measured. In order to verify, it was remeasured by the direct measurement method with a dummy high-voltage capacitor, and before that, the VC of the dummy capacitor was calibrated with a near zero-VC capacitor. The results show a good agreement, and the consistency of the measurement results is better than 1.2 $\times \,\,10^{-6}$ between the two methods. Furthermore, the evaluation of measurement uncertainty in the VC determination of capacitor based on STM is introduced in detail. The evaluation results show that the expanded uncertainty is significantly better than 2.0 $\times \,\,10^{-6}$ , $k =2$ .
17 May 2023 in IEEE Transactions on Instrumentation and Measurement
NIM (National Institute of Metrology, China) and NMIA (National Measurement Institute, Australia) carried out a comparison program, which included low-voltage capacitance, the voltage dependence of high-voltage capacitance and the dielectric dissipation factor (DDF) at 50 Hz. The travelling standards included a low-voltage standard capacitor, a dissipation factor standard and a 100 kV compressed-gas capacitor. The capacitance and DDF of the standard capacitor, measured by the two institutes, agreed within 2 μF/F and 2×10 -6 , respectively, at 50 Hz and 500 V. DDF measurements at nominal values of 0.00000, 0.0001 and 0.001 agreed within 6×10 -6 at 50 Hz and 10 kV. The capacitance change of a 100 kV compressed-gas capacitor measured by the two institutes agreed within 2 μF/F over the voltage range from 10 kV to 100 kV. The success of the program proved comparisons using a re-filled high-voltage compressed gas capacitor and a low-voltage standard capacitor can be conveniently used to validate the complete traceability chain of the measurement of high-voltage capacitance at 50 Hz. The program also proved that DDF measurements with different implementations of traceability chain via capacitance and resistance would agree well within the uncertainties required by industrial measurements and a commercial DDF standard that has undergone international air travel would be sufficiently stable.