Kehinde Olayinka

Kehinde Olayinka

Auto-generated profile, based on publicly available information

Kehinde Olayinka

Department of Chemistry, University of Lagos, University Road, 101017, Lagos, Nigeria

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2023 in Aquatic Sciences
Verified
Journal Article
Closed access
PDF file
FEFolake O. Echebiri
Folake O. Echebiri
AAAkeem Akindele Abayomi
Akeem Akindele Abayomi
NONajeem O. Oladosu
Najeem O. Oladosu
AAAmidu Ayeni
Amidu Ayeni
TATaofikat A. Adesalu
Taofikat A. Adesalu
BABabajide I. Alo
Babajide I. Alo

4 October 2022 in Environmental Science: Water Research & Technology
Verified
Journal Article
Closed access
PDF file
IFIdera Fabunmi
Idera Fabunmi
KPKathryn Proctor
Kathryn Proctor
TOTemilola Oluseyi
Temilola Oluseyi
AOAderonke Oyeyiola
Aderonke Oyeyiola
KOKehinde Olayinka
Kehinde Olayinka
BKBarbara Kasprzyk-Hordern
Barbara Kasprzyk-Hordern
Rapid population growth and urbanisation pose risk to the environment and public health. The aim of this study is to undertake a large-scale spatiotemporal chemical profiling of chemicals of emerging concern (CECs) in the rapidly growing megacity of Lagos, Nigeria. A one-week monitoring study was carried out on 63 target compounds at four wastewater treatment plants (WWTPs) and two sewage disposal points (SDPs) which represent different socioeconomic areas in Lagos metropolis. Forty-eight CECs out of 63 monitored were quantified at least once in the influent and effluent samples. Results showed that tramadol and its metabolite O-desmethyltramadol were the highest contributors to the overall CEC concentrations in influent samples. High variability in weekly trends suggests complexity of sample matrix influencing method performance and variability in CECs across sites. High concentrations of target compounds in effluent of WWTP2 and WWTP4 indicate a poor elimination rate. The results from effluent samples from the constructed wetland showed efficient removal of compounds in a natural system. Generally, the concentrations of target analytes in surface water appear to be independent of distance from discharge points. Occurrence of CECs at very high concentrations in effluent samples and the higher concentrations detected upstream of surface water is a cause for concern. The study proposes promoting the use of constructed wetlands in Lagos metropolis for effective removal of CECs and achieves a sustainable and environmentally friendly mode of treatment.

17 July 2020 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
NONajeem Oladosu
Najeem Oladosu
AAAkeem Akindele Abayomi
Akeem Akindele Abayomi
KOKehinde Olayinka
Kehinde Olayinka
BABabajide Alo
Babajide Alo
The quantitation of nutrient species in the saline water of the Lagos Lagoon was carried out using flow injection analysis (FIA). Due to the Schlieren effect (SE), occasioned by the formation of frontal and rear negative peaks, modified reverse flow injection (rFI) methods were developed for the quantitation. Water samples were collected at 10 sites on and around the Lagoon from 2012 to 2015 and oxidised with acidic potassium persulphate. To eliminate the SE, acid-molybdate reagent was injected into a 36.4 g L−1 salinity carrier in the P manifold, and N-(1-naphthyl) ethylenediamine reagent (NINE) was injected into a 0.16 g L−1 salinity carrier in the N manifold. In both manifolds, the reagent-injection volume was 100 µL. Good turnover rates of 90 h−1 and 120 h−1 were attained for N and total-soluble/total P analysis, respectively. The method detection limit for phosphate-P analysis was 53 µg L−1 while that of nitrate-N analysis was 0.10 mg L−1. The accuracies were within 7% as the average recoveries of PO4 3–P and NO3 –N were 107% and 95%, respectively, in spiked blanks. At the top layer of the Lagoon water, the range of [NO3 −+NO2 −]-N was 0.16 to 0.50 mg L−1 while the soluble reactive P (SRP) was undetectable to 796 µg L−1. Total N (TN) ranged from 1.69 to 21.0 mg L−1 and total P (TP) was 0.13 to 3.94 mg L−1. The study showed that the nutrient limitation (N/P) in the Lagos Lagoon was controlled by rainwater runoff owing to the increased delivery of P to it in the wet season. The distribution of nitrate-N species lacked significant, spatial and temporal variation. Also, the increasing concentration of SRP species viewed against the population density of dwellers around the sites hints at anthropogenic influence.

19 March 2025 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
OFOluwatoyin Tirenioluwa Fatunsin
Oluwatoyin Tirenioluwa Fatunsin
IAIdayat Kikelomo Akinwale
Idayat Kikelomo Akinwale
OAOmobonike Azeezat Akinsanmi
Omobonike Azeezat Akinsanmi
AOAderonke Oyeyiola
Aderonke Oyeyiola
KOKehinde Ololade Olayinka
Kehinde Ololade Olayinka

15 September 2026 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
FEFolake O. Echebiri
Folake O. Echebiri
AAAkeem Akindele Abayomi
Akeem Akindele Abayomi
NONajeem O. Oladosu
Najeem O. Oladosu
KOKehinde O. Olayinka
Kehinde O. Olayinka
BABabajide I. Alo
Babajide I. Alo