Najeem O. Oladosu

Najeem O. Oladosu

Auto-generated profile, based on publicly available information

Najeem O. Oladosu

Department of Chemistry, University of Lagos, Akoka, Lagos, Nigeria

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2017 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
NONajeem O. Oladosu
Najeem O. Oladosu
AAAkeem A. Abayomi
Akeem A. Abayomi
KOKehinde O. Olayinka
Kehinde O. Olayinka
BABabajide I. Alo
Babajide I. Alo

18 April 2023 in Aquatic Sciences
Verified
Journal Article
Closed access
PDF file
FEFolake O. Echebiri
Folake O. Echebiri
AAAkeem Akindele Abayomi
Akeem Akindele Abayomi
NONajeem O. Oladosu
Najeem O. Oladosu
AAAmidu Ayeni
Amidu Ayeni
TATaofikat A. Adesalu
Taofikat A. Adesalu
BABabajide I. Alo
Babajide I. Alo

7 April 2017 in Journal of Analytical Science and Technology
Verified
Journal Article
Open access
PDF file
NONajeem O. Oladosu
Najeem O. Oladosu
AAAkeem A. Abayomi
Akeem A. Abayomi
XZXiang Zhang
Xiang Zhang
KOKehinde O. Olayinka
Kehinde O. Olayinka
BABabajide I. Alo
Babajide I. Alo
ADAnping Deng
Anping Deng
The substitution of hazardous analytical reagents such as Cd with benign alternatives for chemical determination is one of the principles of green chemistry. An eco-friendly Zn reduction method for nitrate determination was developed to achieve this end. Online zinc reduction-sequential injection analysis (ZnR-SIA) protocol was developed for the determination of nitrogen (N) species in the Lagos Lagoon sediments by modification of some standard methods. The novel application of boric acid-borate buffer employed in borate-buffered granular Zn reduction suppressed gas evolution from the Zn micro-column, making the Zn reduction adaptable to online use, unlike the frequently used ammonia-ammonium buffer. Further results showed that the sampling rate for the two-zone stack was 65 h−1. The boric acid-borate buffer offered 5.9-fold and 1.3-fold of the instrument response given by the ammonia-ammonium buffer at 0.50 and 5.0 mg N L−1 respectively. The method detection limits of the ZnR-SIA for the three matrices studied were 24.6 μg N L−1 for reagent water, 0.383 mg N kg−1 for KCl-extractable nitrate, and 3.18 mg N kg−1 for total nitrogen. The average recovery of nitrate-N in matrix samples was 94.7%, and its precision was 4.52%. The average recoveries of total N in blanks and matrix samples were 97.9 and 93.2% respectively. The method accuracies demonstrated the suitability of the ZnR-SIA for sediment N determination. Zn reduction is recommended where sustainable development is desired and is a potential substitute for the standard Cd reduction owing to Cd toxicity.

20 June 2016 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
KOKehinde O. Olayinka
Kehinde O. Olayinka
NONajeem O. Oladosu
Najeem O. Oladosu
AAAkeem A. Abayomi
Akeem A. Abayomi
BABabajide I. Alo
Babajide I. Alo

17 July 2020 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
NONajeem Oladosu
Najeem Oladosu
AAAkeem Akindele Abayomi
Akeem Akindele Abayomi
KOKehinde Olayinka
Kehinde Olayinka
BABabajide Alo
Babajide Alo
The quantitation of nutrient species in the saline water of the Lagos Lagoon was carried out using flow injection analysis (FIA). Due to the Schlieren effect (SE), occasioned by the formation of frontal and rear negative peaks, modified reverse flow injection (rFI) methods were developed for the quantitation. Water samples were collected at 10 sites on and around the Lagoon from 2012 to 2015 and oxidised with acidic potassium persulphate. To eliminate the SE, acid-molybdate reagent was injected into a 36.4 g L−1 salinity carrier in the P manifold, and N-(1-naphthyl) ethylenediamine reagent (NINE) was injected into a 0.16 g L−1 salinity carrier in the N manifold. In both manifolds, the reagent-injection volume was 100 µL. Good turnover rates of 90 h−1 and 120 h−1 were attained for N and total-soluble/total P analysis, respectively. The method detection limit for phosphate-P analysis was 53 µg L−1 while that of nitrate-N analysis was 0.10 mg L−1. The accuracies were within 7% as the average recoveries of PO4 3–P and NO3 –N were 107% and 95%, respectively, in spiked blanks. At the top layer of the Lagoon water, the range of [NO3 −+NO2 −]-N was 0.16 to 0.50 mg L−1 while the soluble reactive P (SRP) was undetectable to 796 µg L−1. Total N (TN) ranged from 1.69 to 21.0 mg L−1 and total P (TP) was 0.13 to 3.94 mg L−1. The study showed that the nutrient limitation (N/P) in the Lagos Lagoon was controlled by rainwater runoff owing to the increased delivery of P to it in the wet season. The distribution of nitrate-N species lacked significant, spatial and temporal variation. Also, the increasing concentration of SRP species viewed against the population density of dwellers around the sites hints at anthropogenic influence.

15 September 2026 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
FEFolake O. Echebiri
Folake O. Echebiri
AAAkeem Akindele Abayomi
Akeem Akindele Abayomi
NONajeem O. Oladosu
Najeem O. Oladosu
KOKehinde O. Olayinka
Kehinde O. Olayinka
BABabajide I. Alo
Babajide I. Alo