Ibrahim A. Metwally

Ibrahim A. Metwally

Auto-generated profile, based on publicly available information

Ibrahim A. Metwally

Electrical Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2018 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
MEMohamed Eladawy
Mohamed Eladawy
IMIbrahim A. Metwally
Ibrahim A. Metwally
In this paper, a novel five-leg design of non-superconducting, three-phase, presaturated core fault-current limiter (PCFCL) is proposed based on the time-domain, electromagnetic finite-element simulations to overcome the main drawbacks of the well-known topologies of PCFCLs. These drawbacks are large volume of magnetic iron core, high total power loss under steady-state condition, high-induced voltage across the dc coil terminals during the fault condition, and the technical risks of high-temperature superconducting coil and cryogenics in the case of superconducting fault-current limiter (SFCLs). The general performance of PCFCL can be expressed through the steady-state power loss and voltage drop, and fault-current clipping ratio and the induced voltage across the dc coil terminals during the fault condition. Different topologies of three-phase PCFCLs are considered with the comparison of their limiting capability for different types of faults. The results reveal that the proposed design of PCFCL has superior properties in limiting any type of fault currents with reduced volume of the magnetic iron core, total power loss, and the induced voltage across the dc coil terminals in comparison with those of the well-known dual-core PCFCL design. Furthermore, a performance analysis of the novel five-leg design is considered throughout an extensive simulation of the constructive controlling parameters to study their relative effects on the general performance of operation.

9 July 2004 in European Transactions on Electrical Power
Verified
Journal Article
Closed access
PDF file
IMI. A. Metwally
I. A. Metwally
FHF. Heidler
F. Heidler
WZW. Zischank
W. Zischank

1 April 2012 in Journal of Electrostatics
Verified
Journal Article
Closed access
IMI.A. Metwally
I.A. Metwally

22 August 2020 in Animals
Verified
Journal Article
Open access
PDF file
Eman ZahranEman Zahran
Eman Zahran
MEMohammed Elmetwally
Mohammed Elmetwally
WAWalaa Awadin
Walaa Awadin
MEMansour El-Matbouli
Mansour El-Matbouli
This study was undertaken to screen levels of xenosteroids (estrogenic endocrine disrupting chemicals/E-EDCs) in Nile tilapia (Oreochromis niloticus) fish farms subjected to water fill from the drain at three sites S1 (highly polluted), S2 (moderately polluted), and a putative reference site (RS). Biometric, hormonal, gene expression, and histopathological analysis were investigated. Testosterone, progesterone, and zeranol residues were detected at (0.12–3.44 µg/L) in water samples of different sites. Bisphenol-A (BPA) exhibited a very high concentration (6.5 µg/mL) in water samples from S1. Testosterone, 17β-estradiol residues were detected in fish tissues from all sites at (0.16–3.8 µg/Kg) and (1.05–5.01 µg/Kg), respectively. BPA residues were detected at a very high concentration in the liver and muscle of fish collected from S1 at higher levels of 25.9 and 48.07 µg/Kg, respectively. The detected E-EDCs, at different sites, particularly BPA, reduced the somatic and testicular growth among sites and oversampling time points. Meanwhile, hepatosomatic index (HSI) was significantly increased in S1 compared to S2. All analyzed genes estrogen receptor-type I (er-I, er-ɑ) and II (er-II, er-ß1), polypeptide 1a (cyp19a1), SRY-box containing gene 9 (sox9), and vitellogenin (vtg) and gonadotropin hormones (luteinizing hormone (LH), follicle-stimulating hormone (FSH)), testosterone, 17β-estradiol, and anti-Mullerian hormone (AMH) were significantly expressed at S1 compared to other sites. Histopathology was more evident in S1 than other sites. These findings warrant immediate strategies development to control aquatic pollution and maintain fish welfare and aquaculture sustainability.

23 July 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
MEMohamed Eladawy
Mohamed Eladawy
IMIbrahim A. Metwally
Ibrahim A. Metwally
In this paper, the dc biasing magnetomotive force (mmf) in presaturated core fault current limiter (PCFCL) is replaced with permanent magnet (PM) to overcome the well-known drawbacks of the dc biased PCFCLs. These drawbacks are excessively induced voltage across the terminals of the dc coil during fault condition and high total power losses during the steady-state condition. The novel contributions of this paper are the introduction of the selection criteria of PM material and its representation by actual nonlinear B-H hysteresis loop of Jiles-Atherton method, and the use of PM alone as an equivalent to the dc biasing coils for three-phase fault current limiter (FCL), contrary to work reported in earlier papers. Single- and three-phase PCFCLs are modified by replacement of dc saturation coil by the equivalent PM through time-domain finite element (FE) simulation of COMSOL Multiphysics package. Experimental verification shows that the implementation of accurate nonlinear representation of PM demagnetization curve with FE simulation gives a realistic performance of the PM biased PCFCL, especially in the fault condition. The performance of PCFCL can be evaluated through the voltage drop and total power losses during the steady-state condition and the fault current clipping ratio during fault condition of the grid. Furthermore, a comparative investigation of dynamic behavior is considered between dc and PM biased PCFCLs. It is found that the PM biased PCFCL has enriched capability of limiting any type of fault current with leading advantages of reduced voltage drop and power losses significantly together with risk elimination of the high induced voltage across dc coil terminals. Moreover, the governing parameters of PM biased PCFCLs are subjected to performance analysis to study their inherent effects.

5 April 2021 in High Voltage
Verified
Journal Article
Open access
PDF file
MEMohamed Eladawy
Mohamed Eladawy
IMIbrahim A. Metwally
Ibrahim A. Metwally
NTNaser G. Tarhuni
Naser G. Tarhuni
The authors present a 500 kV real‐dimension DC‐presaturated fault current limiter (PFCL) with a steady‐state rated current of 2 kA for limiting large fault current of 8 kA with high rate of rise. These characteristics of the fault current can be a threat to high voltage direct current (HVDC) transmission systems, and hence PFCL design and performance improvement are investigated through three‐dimensional, time‐domain, magnetic‐field and electric‐circuit coupled model using finite element simulation of COMSOL Multiphysics package. The nonlinear magnetic characteristics of the soft magnet ensure variable inductance depending on demagnetisation magnetomotive force generated by the line current. This DC‐biased PFCL can replace the traditional smoothing reactor during the normal operation of the system by controlling the level of presaturation. In addition, PFCL is a self‐triggered device and therefore it can automatically limit the fault current and reduce its value below the interruption rating of the used HVDC circuit breakers (CBs). Moreover, the rate of rise of the fault current can be controlled to ensure the compatibility with the available type of HVDC CBs. The dynamic performance of PFCL is investigated during fault condition through the fault current clipping ratio and rate of rise of the fault current, and during steady‐state operation through the voltage drop across PFCL and its power losses. It is found that the proposed PFCL presents adequate capability in limiting large fault currents with extremely low values of voltage drop and power losses during the steady‐state condition. However, the switching transient overvoltages that appear at terminals of PFCL coils during the fault duration have been successfully suppressed by carefully selected ratings of zinc‐oxide surge arresters.