7 May 2021 in Science Advances
This paper presents a sub–0.1-mm 3 , fully integrated, injectable ultrasonic wireless device for biomedical temperature sensing.
17 May 2022 in Proceedings of the National Academy of Sciences
Significance: Modulation of peripheral nervous system (PNS) activity has shown promise in treating a wide range of diseases, from epilepsy to rheumatoid arthritis. Clinically, stimulation of nerves is most commonly delivered through invasive and risk-laden surgical electrode placement. Noninvasive technologies for PNS modulation can both increase safety and expand modulation application to various disease stages. Recent studies have revealed the therapeutic potential of noninvasive neuromodulation of brain circuits with ultrasound. This study identifies reliable protocols and molecular mechanisms for stimulating action potentials from individual peripheral neurons in the mammalian nervous system. These findings reveal the translational potential of ultrasound to effectively modulate the PNS through intrinsic neuronal mechanisms.
1 April 2020 in Journal of Neural Engineering
Objective . Focused ultrasound (FUS) has recently been demonstrated capable of exciting motor neuronal activity. However, comprehensive understanding of elucidated excitatory and inhibitory effects is required to better assess FUS-mediated modulation. In this study, we demonstrate that image-guided FUS can selectively modulate motor neuron activity in the mouse sciatic nerve in vivo and attribute motor responses to thermal effects . Approach . FUS was applied on the sciatic nerve of anesthetized mice in vivo through the intact skin and muscle using ultrasound imaging for targeting. Both excitatory and inhibitory effects were recorded using electromyography (EMG) along with muscle response of the hind limb. The effects of FUS modulation versus heating by invasive alternative heating source (AHS) on electrically evoked EMG responses in the sciatic nerve in vivo were also investigated. The safety and reversibility of the technique were validated using histology and EMG recovery. Main results . The FUS was capable of eliciting motor neuronal activity comparable to electrical stimulation ES, and facilitating motor neuronal response on electrically evoked potentials with temperature elevation up to 11.5 °C ± 0.3 °C (PRF ⩽ 40 Hz). On the other hand, FUS-induced temperature elevations above 15.1 °C ± 1.6 °C (PRF ⩾ 100 Hz) resulted in the suppression of electrically-evoked motor neuronal activity along with a decrease in EMG latency and area under the curve (AUC), which was validated against the invasive AHS with temperature elevation of 18.1 °C ± 8.5 °C. Histological findings along with EMG responses after FUS modulation demonstrated a reversible or irreversible modulation. Significance . The findings reported herein indicate that image-guided FUS (PRF ⩽ 100 Hz) induces safe and controllable modulation of involuntarily evoked motor neuron activity in vivo .
28 October 2020 in IEEE Transactions on Medical Imaging
Focused ultrasound (FUS) is an emerging technique for neuromodulation due to its noninvasive application and high depth penetration. Recent studies have reported success in modulation of brain circuits, peripheral nerves, ion channels, and organ structures. In particular, neuromodulation of peripheral nerves and the underlying mechanisms remain comparatively unexplored in vivo. Lack of methodologies for FUS targeting and monitoring impede further research in in vivo studies. Thus, we developed a method that non-invasively measures nerve engagement, via tissue displacement, during FUS neuromodulation of in vivo nerves using simultaneous high frame-rate ultrasound imaging. Using this system, we can validate, in real-time, FUS targeting of the nerve and characterize subsequent compound muscle action potentials (CMAPs) elicited from sciatic nerve activation in mice using 0.5 to 5 ms pulse durations and 22 - 28 MPa peak positive stimulus pressures at 4 MHz. Interestingly, successful motor excitation from FUS neuromodulation required a minimum interframe nerve displacement of 18 μm without any displacement incurred at the skin or muscle levels. Moreover, CMAPs detected in mice monotonically increased with interframe nerve displacements within the range of 18 to 300 μm. Thus, correlation between nerve displacement and motor activation constitutes strong evidence FUS neuromodulation is driven by a mechanical effect given that tissue deflection is a result of highly focused acoustic radiation force.
20 May 2019 in Applied Physics Letters
Measuring temperature during focused ultrasound (FUS) procedures is critical for characterization, calibration, and monitoring to ultimately ensure safety and efficacy. Despite the low cost and the high spatial and temporal resolutions of temperature measurements using thermocouples, the viscous heating (VH) artifact at the thermocouple-tissue interface requires reading corrections for correct thermometric analysis. In this study, a simulation pipeline is proposed to correct the VH artifact arising from temperature measurements using thermocouples in FUS fields. The numerical model consists of simulating a primary source of heating due to ultrasound absorption and a secondary source of heating from viscous forces generated by the thermocouple in the FUS field. Our numerical validation found that up to 90% of the measured temperature rise was due to VH effects. Experimental temperature measurements were performed using thermocouples embedded in fresh chicken breast samples. Temperature corrections were demonstrated for single high-intensity FUS pulses at 3.1 MHz and for multiple pulses (3.1 MHz, 100 Hz, and 500 Hz pulse repetition frequency). The VH accumulated during sonications and produced a temperature increase of 3.1 °C and 15.3 °C for the single and multiple pulse sequences, respectively. The methodology presented here enables the decoupling of the temperature increase generated by absorption and VH. Thus, more reliable temperature measurements can be extracted from thermocouple measurements by correcting for VH.
25 February 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Focused ultrasound (FUS)-based viscoelastic imaging techniques using high frame rate (HFR) ultrasound to track tissue displacement can be used for mechanistic monitoring of FUS neuromodulation. However, a majority of techniques avoid imaging during the active push transmit (interleaved or postpush acquisitions) to mitigate ultrasound interference, which leads to missing temporal information of ultrasound effects when FUS is being applied. Furthermore, critical for clinical translation, use of both axial steering and real-time (<; 1 s) capabilities for optimizing acoustic parameters for tissue engagement are largely missing. In this study, we describe a method of noninterleaved, single Vantage imaging displacement within an active FUS push with simultaneous axial steering and real-time capabilities using a single ultrasound acquisition machine. Results show that the pulse sequence can track micron-sized displacements using frame rates determined by the calculated time-of-flight (TOF), without interleaving the FUS pulses and imaging acquisition. Decimation by 3-7 frames increases signal-to-noise ratio (SNR) by 15.09±7.03 dB. Benchmarking tests of CUDA-optimized code show increase in processing speed of 35- and 300-fold in comparison with MATLAB parallel processing GPU and CPU functions, respectively, and we can estimate displacement from steered push beams ±10 mm from the geometric focus. Preliminary validation of displacement imaging in humans shows that the same driving pressures led to variable nerve engagement, demonstrating important feedback to improve transducer coupling, FUS incident angle, and targeting. Regarding the use of our technique for neuromodulation, we found that FUS altered thermal perception of thermal pain by 0.9643 units of pain ratings in a single trial. Additionally, 5 $\mu \text{m}$ of nerve displacement was shown in on-target versus off-target sonications. The initial feasibility in healthy volunteers warrants further study for potential clinical translation of FUS for pain suppression.