Min Gon Kim

Min Gon Kim

Auto-generated profile, based on publicly available information

Min Gon Kim

Department of Biomedical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, Pennsylvania, 15213-3815, UNITED STATES

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2024 in Blood
Verified
Journal Article
Open access
MKMin Gon Kim
Min Gon Kim
KYKai Yu
Kai Yu
CYChih-Yu Yeh
Chih-Yu Yeh
RFRaghda Fouda
Raghda Fouda
DADonovan Argueta
Donovan Argueta
BHBin He
Bin He
There is an urgent and unmet clinical need to develop nonpharmacological interventions for chronic pain management because of the critical side effects of opioids. Low-intensity transcranial focused ultrasound (tFUS) is an emerging noninvasive neuromodulation technology with high spatial specificity and deep brain penetration. Here, we developed a tightly focused 128-element ultrasound transducer to specifically target small mouse brains using dynamic focus steering. We demonstrate that tFUS stimulation at pain-processing brain circuits can significantly alter pain-associated behaviors in mouse models in vivo. Our findings indicate that a single-session focused ultrasound stimulation to the primary somatosensory cortex (S1) significantly attenuates heat pain sensitivity in wild-type mice and modulates heat and mechanical hyperalgesia in a humanized mouse model of chronic pain in sickle cell disease. Results further revealed a sustained behavioral change associated with heat hypersensitivity by targeting deeper cortical structures (eg, insula) and multisession focused ultrasound stimulation to S1 and insula. Analyses of brain electrical rhythms through electroencephalography demonstrated a significant change in noxious heat hypersensitivity-related and chronic hyperalgesia–associated neural signals after focused ultrasound treatment. Validation of efficacy was carried out through control experiments, tuning ultrasound parameters, adjusting interexperiment intervals, and investigating effects on age, sex, and genotype in a head-fixed awake model. Importantly, tFUS was found to be safe, causing no adverse effects on motor function or the brain’s neuropathology. In conclusion, the validated proof-of-principle experimental evidence demonstrates the translational potential of novel focused ultrasound neuromodulation for next-generation pain treatment without adverse effects.

1 April 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
MKMin Gon Kim
Min Gon Kim
HKHermes Arytto Salles Kamimura
Hermes Arytto Salles Kamimura
SLStephen A Lee
Stephen A Lee
CAChristian Aurup
Christian Aurup
NKNancy Kwon
Nancy Kwon
EKElisa Konofagou
Elisa Konofagou
Objective . Focused ultrasound (FUS) has recently been demonstrated capable of exciting motor neuronal activity. However, comprehensive understanding of elucidated excitatory and inhibitory effects is required to better assess FUS-mediated modulation. In this study, we demonstrate that image-guided FUS can selectively modulate motor neuron activity in the mouse sciatic nerve in vivo and attribute motor responses to thermal effects . Approach . FUS was applied on the sciatic nerve of anesthetized mice in vivo through the intact skin and muscle using ultrasound imaging for targeting. Both excitatory and inhibitory effects were recorded using electromyography (EMG) along with muscle response of the hind limb. The effects of FUS modulation versus heating by invasive alternative heating source (AHS) on electrically evoked EMG responses in the sciatic nerve in vivo were also investigated. The safety and reversibility of the technique were validated using histology and EMG recovery. Main results . The FUS was capable of eliciting motor neuronal activity comparable to electrical stimulation ES, and facilitating motor neuronal response on electrically evoked potentials with temperature elevation up to 11.5 °C ± 0.3 °C (PRF ⩽ 40 Hz). On the other hand, FUS-induced temperature elevations above 15.1 °C ± 1.6 °C (PRF ⩾ 100 Hz) resulted in the suppression of electrically-evoked motor neuronal activity along with a decrease in EMG latency and area under the curve (AUC), which was validated against the invasive AHS with temperature elevation of 18.1 °C ± 8.5 °C. Histological findings along with EMG responses after FUS modulation demonstrated a reversible or irreversible modulation. Significance . The findings reported herein indicate that image-guided FUS (PRF ⩽ 100 Hz) induces safe and controllable modulation of involuntarily evoked motor neuron activity in vivo .

13 November 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MKMin Gon Kim
Min Gon Kim
KYKai Yu
Kai Yu
XNXiaodan Niu
Xiaodan Niu
BHBin He
Bin He
Transcranial focused ultrasound (tFUS) is an emerging neuromodulation technique to modulate brain activity non-invasively with high spatial specificity and focality. Given the influence of tFUS on brain activity, combining tFUS with multi-channel intracranial electrophysiological recordings enables monitoring of the activity of large populations of neurons with high temporal resolution. However, the physical interactions between tFUS and the electrode may affect a reliable assessment of neuronal activity, which remains poorly understood. In this article, high-frequency ultrasound (HFUS) system was developed and integrated into the tFUS neuromodulation system. The performance of the HFUS-based displacement tracking and analysis was evaluated by the theoretical analysis in the literature. The effects of various pressure levels on the displacements of the silicon-based microelectrode array in ex vivo brain tissue were investigated. The developed approach was capable of tracking and measuring the motion of a solid sphere in a tissue-mimicking phantom and measured displacements were comparable to theoretical predictions. The significant changes in the averaged peak displacements of the microelectrode array in ex vivo brain were observed with a pulse duration of 200 $\mu \text{s}$ and a peak-to-peak pressure from 131 kPa at a center frequency of 500 kHz compared with the values from the negative control group. The present results demonstrate the relationship between several pressure levels and displacements of the microelectrode array in ex vivo brain through the developed approach. This approach can be used to determine a vibration-free threshold of ultrasound parameters in multi-channel intracranial recordings for a reliable assessment of electrophysiological activities of living neurons.

19 February 2025 in APL Bioengineering
Verified
Journal Article
Open access
MKMin Gon Kim
Min Gon Kim
CYChih-Yu Yeh
Chih-Yu Yeh
KYKai Yu
Kai Yu
ZLZherui Li
Zherui Li
KGKalpna Gupta
Kalpna Gupta
BHBin He
Bin He
Low-intensity transcranial focused ultrasound (tFUS) has recently been shown to noninvasively and non-pharmacologically modulate pain hypersensitivity with high spatial specificity and deep brain penetration. However, the lack of knowledge about its effectiveness for pain management in older subjects vulnerable to severe pain who are also at increased risk of cognitive impairment, presents significant challenges. Additionally, current opioid pain treatments require hospital visits, limiting unwanted serious side effects with multiple liabilities, and device-based pain treatments are typically administered at medical facilities with bulky and expensive equipment, limiting accessibility and thus highlighting the need for at-home non-pharmacological treatment options. Here, we present a more accessible, noninvasive tFUS pain treatment strategy for senior subjects. This approach involves simultaneously targeting multiple pain-processing circuits using a battery-powered, compact, and low-cost ultrasound analog front end (UAFE). We developed and evaluated the performance of the UAFE capable of generating sufficiently high-amplitude output with significantly lower noise levels compared to a commercial transmitter. Using a humanized sickle mouse model of chronic hyperalgesia, we found that tFUS stimulation targeting multiple pain-processing circuits effectively reduces heat hyperalgesia in aged female mice. In addition to its efficacy, our behavioral-based safety assessment revealed no adverse effects on motor functions. These results suggest that using a battery-powered, compact UAFE to simultaneously target multiple pain-processing circuits can effectively suppress heat pain-related behaviors in aged female sickle mice without negatively impacting motor coordination and balance. This highlights the potential for further development of fully home-based tFUS pain treatment for seniors.

1 April 2026 in Journal of Neural Engineering
Verified
Journal Article
Open access
MKMin Gon Kim
Min Gon Kim
CYChih-Yu Yeh
Chih-Yu Yeh
HGHuan Gao
Huan Gao
KLKeunhyung Lee
Keunhyung Lee
KGKalpna Gupta
Kalpna Gupta
BHBin He
Bin He
Objective. Low-intensity transcranial focused ultrasound (tFUS) offers high spatial specificity and deep brain penetration, representing a promising non-invasive approach for modulating brain activity and behavior. Although emerging studies indicate that tFUS can modulate pain-related behaviors in rodents and humans, the underlying network-level and cellular mechanisms remain unknown. This study investigates the effects of tFUS neuromodulation on inhibitory neural circuits in a humanized mouse model of chronic pain, integrating electrophysiological, molecular, and histological analyses across a cohort of 50 animals, including wild-type controls. Approach. A 128-element random array transducer was used to precisely target the pain-processing brain circuit, while a non-invasive and flexible 30-channel electroencephalography electrode was applied to record local evoked responses, topographical activity, and global excitation and inhibition dynamics, which were further validated by optogenetics experiments. Cellular-level modulation and safety outcomes were evaluated through blinded histological examination. Main results. We found that tFUS produced robust modulation of local and global brain activity, characterized by suppression of local theta oscillations and enhancement of network-level inhibitory dynamics. These electrophysiological patterns aligned with those observed during optogenetic activation of parvalbumin (PV) interneurons. Immunohistochemistry further showed significant increases in inhibitory neuronal markers, including elevated expressions of glutamate decarboxylase 67 and PV. Blinded histological assessment confirmed the absence of tissue damage, supporting the safety of the stimulation paradigm. Significance. These findings demonstrated that tFUS stimulation non-invasively engages PV GABAergic inhibitory circuits in a chronic pain mouse model, providing mechanistic insight and supporting its development as a precise and safe neuromodulation technology for clinical translation.