Bruno Leandro Pereira

Bruno Leandro Pereira

Auto-generated profile, based on publicly available information

Bruno Leandro Pereira

Department of Mechanical Engineering, Pontifícia Universidade Católica do Paraná, Curitiba 80215-901, PR, Brazil

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
BPBruno Leandro Pereira
Bruno Leandro Pereira
ALAline Rossetto da Luz
Aline Rossetto da Luz
CLCarlos Maurício Lepienski
Carlos Maurício Lepienski
IMIrineu Mazzaro
Irineu Mazzaro
NKNeide Kazue Kuromoto
Neide Kazue Kuromoto

1 January 2020 in Materials Research
Verified
Journal Article
Open access
PDF file
BPBruno Leandro Pereira
Bruno Leandro Pereira
CLCarlos Maurício Lepienski
Carlos Maurício Lepienski
VSViviane Seba
Viviane Seba
GHGuibert Hobold
Guibert Hobold
PSPaulo Soares
Paulo Soares
MNMichael Nugent
Michael Nugent
The present study produced binary titanium-niobium alloys Ti-xNb with high niobium percentage (x = 50, 80 e 90 wt.%) aiming to apply it as a base material in osseous implant devices. The produced TiNb alloys presented a cubic crystalline phase, lower corrosion rate than titanium, lower elastic modulus values, and superior cellular viability than titanium and niobium. The Ti50Nb alloy among all analyzed metallic substrates showed the best values of elastic modulus, corrosion properties, wettability, and cellular viability. Thus, this work suggests a Ti/Nb ratio close to 1 (Ti50Nb) displays optimum characteristics to apply in orthopedic devices.

10 May 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ABAbhishek Bhattacharjee
Abhishek Bhattacharjee
EGEmma Goodall
Emma Goodall
BPBruno Leandro Pereira
Bruno Leandro Pereira
PSPaulo Soares
Paulo Soares
Ketul C PopatKetul C Popat
Ketul C Popat
Titanium (Ti) is a popular biomaterial for orthopedic implant applications due to its superior mechanical properties such as corrosion resistance and low modulus of elasticity. However, around 10% of these implants fail annually due to bacterial infection and poor osseointegration, resulting in severe pain and suffering for the patients. To improve their performance, nanoscale surface modification approaches and doping of trace elements on the surfaces can be utilized which may help in improving cell adhesion for better osseointegration while reducing bacterial infection. In this work, at first, titania (TiO2) nanotube arrays (NT) were fabricated on commercially available pure Ti surfaces via anodization. Then zinc (Zn) doping was conducted following two distinct methods: hydrothermal and alkaline heat treatment. Scanning electron microscopic (SEM) images of the prepared surfaces revealed unique surface morphologies, while energy dispersive X-ray spectroscopy (EDS) revealed Zn distribution on the surfaces. Contact angle measurements indicated that NT surfaces were superhydrophilic. X-ray photoelectron spectroscopy (XPS) provided the relative amount of Zn on the surfaces and indicated that hydrothermally treated surfaces had more Zn compared to the alkaline heat-treated surfaces. X-ray crystallography (XRD) and nanoindentation techniques provided the crystal structure and mechanical properties of the surfaces. While testing with adipose-derived stem cells (ADSC), the surfaces showed no apparent cytotoxicity to the cells. Finally, bacteria adhesion and morphology were evaluated on the surfaces after 6 h and 24 h of incubation. From the results, it was confirmed that NT surfaces doped with Zn drastically reduced bacteria adhesion compared to the Ti control. Zn-doped NT surfaces thus offer a potential platform for orthopedic implant application.

6 August 2021 in Polymers
Verified
Journal Article
Open access
PDF file
VSViviane Seba Sampaio
Viviane Seba Sampaio
Gabriel de LimaGabriel de Lima
Gabriel de Lima
BPBruno L. Pereira
Bruno L. Pereira
GSGabriel Silva
Gabriel Silva
LRLuiza Steffens Reinhardt
Luiza Steffens Reinhardt
MMMozart Marins
Mozart Marins
Chalcones (1,3-diaryl-2-propen-1-ones) are naturally occurring polyphenols with known anticancer activity against a variety of tumor cell lines, including osteosarcoma (OS). In this paper, we present the preparation and characterization of spheres (~2 mm) from polyvinyl alcohol (PVA) containing a combination of 4′-Amino-1-Naphthyl-Chalcone (D14) and doxorubicin, to act as a new polymeric dual-drug anticancer delivery. D14 is a potent inhibitor of osteosarcoma progression and, when combined with doxorubicin, presents a synergetic effect; hence, physically crosslinked PVA spheres loaded with D14 and doxorubicin were prepared using liquid nitrogen and six freeze–thawing cycles. Physical-chemical characterization using a scanning electron microscope (SEM), differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD) presented that the drugs were incorporated into the spheres via weak interactions between the drugs and the polymeric chains, resulting in overall good drug stability. The cytotoxicity activity of the PVA spheres co-encapsulating both drugs was tested against the U2OS human osteosarcoma cell line by 3- (4,5-dimethylthiazol-2-yl) -2,5-diphenyltetrazolium bromide (MTT) assay, and compared to the spheres carrying either D14 or doxorubicin alone. The co-delivery showed a cytotoxic effect 2.6-fold greater than doxorubicin alone, revealing a significant synergistic effect with a coefficient of drug interaction (CDI) of 0.49. The obtained results suggest this developed PVA sphere as a potential dual-drug delivery system that could be used for the prominent synergistic anticancer activity of co-delivering D14 and doxorubicin, providing a new potential strategy for improved osteosarcoma treatment.

1 January 2021 in Matéria (Rio de Janeiro)
Verified
Journal Article
Open access
PDF file
GBGregory Beilner
Gregory Beilner
BPBruno Leandro Pereira
Bruno Leandro Pereira
Carlos Mauricio LepienskiCarlos Mauricio Lepienski
Carlos Mauricio Lepienski
GSGelson B. De Souza
Gelson B. De Souza
ESErico Saito Szameitat
Erico Saito Szameitat
MNMichael Nugent
Michael Nugent
Among titanium alloys with non-toxic elements, the Ti-25Nb-25Ta alloy has good elastic behavior for applications in osseous implants, biocompatibility, and excellent corrosion resistance. The present study aimed to better the biocompatibility characteristics of Ti-25Nb-25Ta alloy modifying its surface through Plasma Electrolytic Oxidation (PEO) treatment. The formed oxide coating is amorphous and composed of two distinct porous formations: smaller hole-shaped pores and larger volcano-like pores. The regions with the formation of smaller pores and in the hole shaped presented the highest atomic percentage of the chemical element phosphorus. Nanoindentation tests have shown that the hardness of the Ti-25Nb-25Ta alloy is slightly lower than the commercially pure grade 2 titanium (a material used as reference), while elastic modulus measurements of Ti-25Nb-25Ta presented more suitable values for implant application (lower values when compared with titanium reference). After PEO treatment there were significant mechanical surface improvements (increased fairly surface hardness and decreased elastic modulus) for application in osseous tissue. Despite the Ti-25Nb-25Ta alloy presented excellent characteristics for applications in hard biological tissues, the PEO treatment better its features.

17 February 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
ASAniruddha Vijay Savargaonkar
Aniruddha Vijay Savargaonkar
EHEmma Holloway
Emma Holloway
LMLiszt Y.C. Madruga
Liszt Y.C. Madruga
BPBruno L Pereira
Bruno L Pereira
PSPaulo Soares
Paulo Soares
KPKetul C Popat
Ketul C Popat
Titanium and its alloys have been the material of choice for orthopedic implants due to their excellent physical properties as well as biocompatibility. However, titanium is not able to integrate with bone due to the mismatch of mechanical properties. Additionally, bone has a micro–nano hierarchy, which is absent on titanium’s surface. A potential solution to the former is to make the surfaces porous to bring the mechanical properties closer to that of the bone, and a solution for the latter is to fabricate nanostructures. In this study, micro-porous titanium surfaces were hydrothermally treated using an alkali medium to fabricate nanostructures on the existing micro-porosity of the surface. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, X-ray diffraction, and nanoindentation. The anti-bacterial properties of the surfaces were evaluated against Gram-positive and Gram-negative bacteria using fluorescence microscopy and scanning electron microscopy. Blood clotting is shown to improve the surface-to-bone integration; hence, whole blood clotting and platelet adhesion and activation were evaluated using a whole blood clotting assay, fluorescence microscopy, and scanning electron microscopy. The results indicate that nanostructured micro-porous titanium surfaces display significantly enhanced anti-bacterial properties as well as equivalent blood clotting characteristics compared to non-porous titanium surfaces.