In this paper, a low-power, low-noise chopper stabilized CMOS differential difference instrumentation amplifier (CHDDA) for portable biopotential acquisition applications is presented. The proposed 130 nm CMOS chopper stabilized amplifier has 3.2 μW power dissipation, thermal noise floor of 10 nV/rtHz and corner frequency in the vicinity of 10 Hz with 1 V supply voltage which performs adequately well in measuring biopotential signals.
In this paper, a low-noise CMOS readout front end for biopotential acquisition applications is presented. The proposed circuit, implemented using 130 nm standard CMOS process, has a thermal noise floor of 10 nV/√Hz, a corner frequency of 300 mHz, and dissipates 3.2μW of power when powered using a 1 V supply. The designed circuit occupies a die area of 0.007mm 2 and thus renders itself as an excellent candidate for acquiring biopotential signals through MEMS sensors.
3 July 2024 in International Journal of Circuit Theory and Applications
This paper discusses a low-noise read-out amplifier circuit for a biomedical sensor interface. The amplifier has two amplification stages with a Miller compensation capacitor that offers high gain with a large output swing. For power efficiency, all transistors are operated in a sub-threshold regime that makes the design suitable for implantable and portable medical devices. The proposed design works at the heart of bio-medical sensor interface circuits. It offers an amplification for different bio-potential signals such as electroencephalogram (EEG), electrocardiogram (ECG), and electromyogram (EMG) according to its bandwidth (BW). Furthermore, a small signal model analysis of the proposed amplifier is presented. A chopping technique is also proposed to reduce the sensor offset voltage and the flicker noise generated from sensor interface circuits. The proposed amplifier design achieves a gain and a BW of 62.16 dB and 506 Hz respectively. The input common-mode range (ICMR) varies from 0.3 V to 0.8 V with a phase margin (PM) of 62.57◦ at VCM equals 0.3 V and 66.8◦ at VCM of 0.8 V. The circuit is designed in 130 nm CMOS technology and consumes a power of 0.4 µW from 1 V supply. Also, the chopping technique reduces input-referred voltage noise from 38.445 µV/sqrt(Hz) to 3.06 µV/sqrt(Hz) within a frequency range from 0.01Hz to 500Hz.
A calibration-free low-power circuit is proposed to reduce the sensitivity of LC VCOs to power supply variations, i.e. supply-pushing. Detailed analysis and design procedure of the proposed circuit are presented and verified by simulations. To illustrate the strength of the proposed technique, the VCO is simulated with and without the proposed circuit. At the highest K v value of 26 MHz/V, simulation results show 14.5-kHz and 1.01-MHz peak-to-peak deviation from a 1.9-GHz center frequency for a 50-mV supply variation with and without the proposed circuit, respectively. This is equivalent to a supply pushing of 290 kHz/V and 20 MHz/V with and without the proposed circuit, respectively. This represents about 70-times improvement in supply pushing over conventional VCO implementations. In addition, the proposed technique achieves a worst case frequency error of 126 kHz across all process and temperature variations with no calibration. Moreover, the proposed circuit shows negligible effect on the VCO phase noise. At 1.9 GHz, the phase noise of the VCO with the proposed circuit is only degraded by 2.9 dB and 0.1 dB at frequency offsets of 100 kHz and 1 MHz, respectively. The proposed circuit consumes less than 20 μA and occupies less than 1.5 % of the total area of the VCO in 90-nm RF CMOS technology.