Dongping Wang

Dongping Wang

Auto-generated profile, based on publicly available information

Dongping Wang

School of Information Science and Engineering, Shandong University, Qingdao, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
SOShihong Ouyang
Shihong Ouyang
YXYingtao Xie
Yingtao Xie
DWDongping Wang
Dongping Wang
DZDalong Zhu
Dalong Zhu
XXXin Xu
Xin Xu
HFHon Hang Fong
Hon Hang Fong
Along with the development of organic electronics, conductive polymer of PEDOT:PSS has been attracting more and more attention because they possess various novel electrical, optical, and mechanical properties, which render them useful in modern organic optoelectronic devices. Due to its organic nature, it is lightweight and can be fabricated into flexible devices. For better device processing and integrating, it is essential to tune their surface morphologies, and photolithography is the best choice at present. In this paper, current PEDOT:PSS patterning approaches using photolithography are reviewed, and some of our works are also briefly introduced. Appropriate photolithographic patterning process for PEDOT:PSS will enable its application in future organic electronics.

26 February 2024 in iScience
Verified
Journal Article
Open access
DWDongping Wang
Dongping Wang
KJKai Jin
Kai Jin
JJJiajian Ji
Jiajian Ji
CHChenxuan Hu
Chenxuan Hu
MDMaohua Du
Maohua Du
Hanbin MaHanbin Ma
Hanbin Ma
Digital liquid sample handling is an enabling tool for cutting-edge life-sciences research. We present here an active-matrix thin-film transistor (TFT) based digital microfluidics system, referred to as Field Programmable Droplet Array (FPDA). The system contains 256 × 256 pixels in an active area of 10.65 cm2, which can manipulate thousands of addressable liquid droplets simultaneously. By leveraging a novel TFT device and circuits design solution, we manage to programmatically manipulate droplets at single-pixel level. The minimum achievable droplet volume is around 0.5 nL, which is two orders of magnitude smaller than the smallest droplet ever reported on active-matrix digital microfluidics. The movement of droplets can be either pre-programmed or controlled in real-time. The FPDA system shows great potential of the ubiquitous thin-film electronics technology in digital liquid handling. These efforts will make it possible to create a true programmable lab-on-a-chip device to enable great advances in life science research.

1 June 2022 in Flexible and Printed Electronics
Verified
Journal Article
Open access
DWDongping Wang
Dongping Wang
ZLZhe Liu
Zhe Liu
JLJun Li
Jun Li
WTWei Tang
Wei Tang
YHYukun Huang
Yukun Huang
HMHanbin Ma
Hanbin Ma
Thin-film transistor (TFT) active matrix (AM) arrays have been developed to achieve many applications, including flat panel displays, digital x-rays, digital microfluidics (DMF) and high-throughput biosensors. Here, we focus on a review on TFT array technologies for biological sensing systems, which are regarded as one of the most promising emerging application fields of TFTs. As an important part of the biological sensing system, the DMF chip will be introduced. In particular, development of the TFT-based AM DMF (AM-DMF) chips, which possess the characteristics of higher throughput and higher flexibility of manipulating liquid samples, will be discussed in details. Further, the developed TFT array based biological sensing systems will be summarized and discussed as well. Finally, we present prospects for AM-DMF chips and biosensors, along with a brief conclusion.

21 November 2025 in Nature Reviews Electrical Engineering
Verified
Journal Article
Closed access
PDF file
DWDongping Wang
Dongping Wang
SJShengzhe Jiang
Shengzhe Jiang
Hanbin MaHanbin Ma
Hanbin Ma
JYJun Yu
Jun Yu
ANArokia Nathan
Arokia Nathan

27 February 2024 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
BZBingbing Zhang
Bingbing Zhang
JFJinxin Fu
Jinxin Fu
MDMaohua Du
Maohua Du
KJKai Jin
Kai Jin
QHQi Huang
Qi Huang
Hanbin MaHanbin Ma
Hanbin Ma
Advancing active-matrix digital microfluidics through polar coordinates for precise concentration gradients. Demonstrated with chip photography, concentration gradient solution demo, and efficiency comparison.

7 July 2023 in IEEE Journal of the Electron Devices Society
Verified
Journal Article
Open access
DWDongping Wang
Dongping Wang
SWShiqiang Wu
Shiqiang Wu
QHQi Huang
Qi Huang
CCChunyu Chang
Chunyu Chang
LXLongqian Xu
Longqian Xu
Hanbin MaHanbin Ma
Hanbin Ma
Emerging microfluidic tools are bringing new approaches to biological experiments on the scale of microdroplets and single cells. In this study, we designed an active-matrix digital microfluidics chip and investigated a driving signal strategy. The driving factors of ‘holding time’ and ‘delay time’ in the activematrix drive timing and the stability of droplet manipulation were optimized. Then, the drive signal was optimized to finally achieve the stable control of two different single high-throughput droplets. In this process, we also investigated how to maintain the stability of droplet driving while reducing the electrode degradation, extending the electrode and TFT circuit life and increasing the duration of the AM-DMF chip. The above work provides experience in the stable manipulation of single cells and the application of high-throughput droplet driving while allowing for cost savings.