4 June 2018 in IEEE Transactions on Power Systems
This study presents a method of estimating the effective inertia of a power system from ambient frequency and active power signals measured by PMUs. Most importantly, we demonstrate that inertia can be estimated from ambient measurement data, not only from disturbances. This leads to the possibility of monitoring inertia in a close to continuous manner in the time scale of minutes or tens of minutes. The method allows the system to be divided into a number of areas and the effective inertia of each area to be estimated as a separate quantity. In principle, inertia is estimated by observing the dynamics between changes in active power and resulting frequency deviations during normal operation of the system. The method is based on applying system identification on these measurements and extracting inertia values from identified models. Efficacy of the method is demonstrated on results of real measurements from the Icelandic power system.
2 August 2022 in Electric Power Systems Research
19 January 2021 in IEEE Transactions on Power Delivery
This paper presents an asset health index (HI) prediction methodology for high voltage transmission overhead lines (OHLs) using supervised machine learning and structured, unambiguous visual inspections. We propose a framework for asset HI predictions to determine the technical condition of individual OHL towers to improve grid reliability in a cost-effective manner. The paper focuses on asset HI prediction and the selection of the most parsimonious model. Based on the technical specifications and HI data, our methodology allows for the prediction of a HI for OHLs without HI data, and models asset aging behaviour. Technical specifications and the HI as defined in this paper are taken from the Estonian TSO periodical visual inspections implemented in 2018. The case study successfully demonstrates that the proposed methodology can predict tower HI values for a single OHL with nearly 80 percent accuracy without the need for additional measurements.
27 March 2022 in Electric Power Systems Research
4 February 2022 in IEEE Access
This paper presents a robust and adaptive out-of-step (OOS) protection algorithm, using wide-area information, that can be applied on tie-lines in observable power systems. The developed algorithm is based upon real-time computation of the system impedance and makes use of the well-known power-angle characteristic. In this way, a setting-less OOS concept in real-time environment is developed, which is applicable for tie-lines in an arbitrary power system. Furthermore, the developed protection algorithm is installed on hardware and is verified by numerous tests. The performance of the new hardware implementation is compared to the traditional impedance-based OOS protection methods. The results confirm that the proposed algorithm detects OOS conditions faster and more reliably than the traditional impedance-based solutions.
1 May 2022 in International Journal of Electrical Power & Energy Systems