1 March 2002 in Journal of Orthopaedic Trauma
The purpose of this manuscript is to review techniques of optimizing the interface between the bone and pin in external fixation to minimize pin loosening and infection. Among the different techniques to improve the bone-pin interface in external fixation, coating the pins with hydroxyapatite proved to be the most effective. In a highly loaded animal study, three pin types were compared. Type A remained uncoated, type B was coated with hydroxyapatite, and Type C was coated with titanium. Radiographic rarefaction of the bone pin tract was lower in type B pins. Extraction torque was thirteen times higher in type B pins compared to type A and two times higher compared to type C pins. Extraction torque was significantly lower compared to the corresponding insertion torque in both types A and C. In contrast, in the hydroxyapatite coated pins there was no difference between extraction and insertion torque. At sixty times magnification, bone pin contact of type B and C pins was significantly higher than type A. At 10,000 times magnification direct bone pin contact was found only in type B pins. In a clinical study the pin insertion and extraction torque forces were measured in a study of seventy-six external fixation pins in nineteen patients treated with hemicallotasis for osteoarthritis of the medial side of the knee. The patients were randomized to be treated with either standard tapered pins or tapered pins coated with hydroxyapatite. Extraction torque of the hydroxyapatite coated pins was higher than the standard ones in both cancellous and cortical bone. These studies show that in hydroxyapatite coated pins there is no deterioration of the bone-pin interface strength and there is optimal bone-pin contact. Among the various pin types coated with hydroxyapatite, the best results were obtained with the tapered pins.
1 May 2001 in Journal of Bone and Joint Surgery
Achieving adequate fixation strength in osteoporotic bone is a challenge. In this study, we examined the use of hydroxyapatite-coated tapered external-fixation pins for the fixation of wrist fractures in patients with osteoporosis. Twenty female patients with osteoporosis and a fracture of the wrist were divided into two paired groups and randomized to receive either standard tapered pins or hydroxyapatite-coated tapered pins. Two pins were inserted in the distal part of the radius, two pins were inserted in the second metacarpal, and an external fixation device was mounted. All fixation devices were removed six weeks after surgery. The mean pin-insertion torque (and standard deviation) was 461 +/- 254 Nmm in the group managed with standard pins and 332 +/- 176 Nmm in the group managed with hydroxyapatite-coated pins (p = 0.01). The mean pin-extraction torque was 191 +/- 155 Nmm in the group managed with standard pins and 600 +/- 214 Nmm in the group managed with hydroxyapatite-coated pins (p < 0.0001, power 95%). The mean extraction torque was lower than the corresponding insertion torque at each pin position in the group managed with standard pins (p < 0.05), whereas the mean extraction torque was higher than the corresponding insertion torque at each pin position in the group managed with hydroxyapatite-coated pins (p = 0.001). Two patients managed with standard pins and no patient managed with hydroxyapatite-coated pins had a pin-track infection. Pain during pin removal did not differ between the two groups. The present study showed that hydroxyapatite-coated tapered external-fixation pins provided improved fixation in the treatment of wrist fractures in patients with osteoporosis.
1 April 2005 in Journal of Bone and Joint Surgery
Background: Although the use of a sliding hip screw is considered to be the preferred treatment for pertrochanteric femoral fractures, we theorized that external fixation could produce clinical outcomes equal to, if not better than, the outcomes obtained with conventional treatment. Furthermore, because external fixation is minimally invasive, we expected a lower rate of morbidity and a reduced need for blood transfusions. Therefore, we compared the two treatments in a clinical trial of elderly patients with pertrochanteric fracture. Methods: Forty consecutive elderly female patients who had a pertrochanteric fracture were randomized to be treated with either fixation with a 135° four-hole sliding hip screw (Group A) or an external fixation device with hydroxyapatite-coated pins (Group B). The inclusion criteria were female gender, an age of at least sixty-five years, an AO/OTA type-A1 or A2 fracture, and a bone mineral density T-score of less than -2.5. There were no differences in patient age, fracture type, bone mineral density, comorbidities, length of hospital stay, or quality of reduction between the two groups. Results: The average intraoperative time (and standard deviation) was 64 ± 6 minutes in Group A and 34 ± 5 minutes in Group B (p < 0.005). The average number of units of blood transfused postoperatively was 2.0 ± 0.1 in Group A and none in Group B (p < 0.0001). Group B had less pain five days postoperatively (p < 0.05). Varus collapse of the fracture at six months averaged 6° ± 8° in Group A and 2° ± 1° in Group B (p < 0.002). No pin-track infections occurred in Group B. The average Harris hip score at six months was 62 ± 19 points in Group A and 63 ± 17 points in Group B. Conclusions: This study showed that external fixation with hydroxyapatite-coated pins is an effective treatment for this fracture in this patient population. The operative time is brief, the blood loss is minimal, the fixation is adequate, and the reduction is maintained over time. Level of Evidence: Therapeutic Level I. See Instructions to Authors for a complete description of levels of evidence.
1 January 2007 in Journal of Bone and Joint Surgery
Background: Animal studies have demonstrated the efficacy of the use of bisphosphonates to enhance screw fixation in bone. In this prospective, randomized study of pertrochanteric fractures treated with external fixation, we tested whether systemic administration of bisphosphonates would improve the fixation of hydroxyapatite-coated screws implanted in osteoporotic bone. Methods: Sixteen consecutive patients with a pertrochanteric fracture were selected. Inclusion criteria were female gender, an age of at least sixty-five years, and a bone mineral density T-score of less than –2.5 standard deviations. Exclusion criteria included bisphosphonate treatment during the two-year period prior to the fracture. Fractures were fixed with a pertrochanteric fixator and four hydroxyapatite-coated pins. Two pins were implanted in the femoral head (pin positions 1 and 2), and two were placed in the femoral diaphysis (pin positions 3 and 4). The patients were randomized either to therapy with alendronate for a three-month postoperative period (Group A) or to no therapy (Group B). The Group-A patients received an oral dose of 70 mg of alendronate per week. The fixators were removed after three months. Results: All of the fractures healed, and no loss of reduction, nonunion, or delayed union was observed. The combined mean extraction torque (and standard deviation) of the pins implanted at positions 1 and 2 (cancellous bone) was 2558 ± 1103 N/mm in Group A and 1171 ± 480 N/mm in Group B (p < 0.0005). The combined mean extraction torque of the pins implanted at positions 3 and 4 (cortical bone) was 4327 ± 1720 N/mm in Group A and 4075 ± 1022 N/mm in Group B. Conclusions: These data show that weekly systemic administration of alendronate improves pin fixation in cancellous bone in elderly female patients with osteoporosis. We observed a twofold increase in extraction torque with the pins implanted in cancellous bone. These results support the use of alendronate in the treatment of osteoporotic pertrochanteric fractures to improve screw fixation in the femoral head. Level of Evidence: Therapeutic Level I. See Instructions to Authors for a complete description of levels of evidence.
1 August 2004 in Clinical Orthopaedics and Related Research
This study was done to determine if elderly patients with trochanteric fractures and with osteoporosis could benefit from treatment with a dynamic hip screw fixed with HA-coated AO/ASIF screws. One hundred twenty patients with AO, A1, or A2 trochanteric fractures were selected. Patients were divided into two groups and randomized to receive a 135°-four–hole dynamic hip screw fixed with either standard lag and cortical AO/ASIF screws (Group A), or HA-coated lag and cortical AO/ASIF screws (Group B). Lag screw cutout occurred in four patients in Group A, but not in any patients in Group B. In Group A, the femoral neck shaft angle was 134° ± 5° postoperatively and 127° ± 12° at 6 months. In Group B, the femoral neck shaft angle was 134° ± 7° postoperatively and 133° ± 7° at 6 months. The Harris hip score at 6 months was 60 ± 25 in Group A and 71 ± 18 in Group B. The superior results of Group B can be attributed to the increased screw fixation provided by the HA-coated screws. We recommend lag screws coated with HA for dynamic hip screw fixation, especially in osteoporotic bone.
1 July 2005 in Expert Review of Medical Devices
The aim of this review is to report on studies of hydroxyapatite-coated external fixation pins as a solution to enhance pin fixation. In a highly loaded animal study, three tapered pin types were compared: Type A uncoated, Type B coated with hydroxyapatite and Type C coated with titanium. There was a 13-fold increase in the extraction torque of Type B pins compared with Type A, and a twofold increase compared with Type C pins. Extraction torque was significantly lower compared with the corresponding insertion torque in both Types A (p < 0.001) and C (p = 0.003). Conversely, with the hydroxyapatite-coated pins there was no difference between extraction and insertion torque. In a clinical study of 76 external fixation pins in 19 patients treated with hemicallotasis for osteoarthritis on the medial side of the knee, pin insertion and extraction torque forces were measured. The patients were randomized to be treated with either standard tapered pins or tapered pins coated with hydroxyapatite. Extraction torque of the hydroxyapatite-coated pins was higher than the extraction torque of the standard pins in both cancellous and cortical bone (p < 0.005). In a prospective, randomized clinical study of osteoporotic wrist fractures, extraction torque of the coated pins was higher than with standard pins (p < 0.0001). These studies demonstrate that with the use of hydroxyapatite-coated pins, no deterioration of pin fixation occurs, and that there is no significant pin loosening and infection, regardless of bone type and loading conditions.