Roland Ten Klooster

Roland Ten Klooster

Auto-generated profile, based on publicly available information

Roland Ten Klooster

Department of Design, Production and Management, Faculty of Engineering Technology University of Twente Enschede The Netherlands

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2025 in Packaging Technology and Science
Verified
Journal Article
Open access
MBMieke van Den Berg
Mieke van Den Berg
RKRoland Ten Klooster
Roland Ten Klooster
In this paper, the factors taken up in LCA studies comparing single‐use to reuse are evaluated. Based on literature research, the insight was obtained that there are many single‐use vs. reuse comparisons that do not take into account the full picture of a reuse system. These factors are defined and further explored using single‐use/reuse system comparison case studies. A method to calculate the impact of reuse systems and to compare it to single‐use systems is presented in terms of equations based on the case studies. The equations are used to show the relevance of taking up specific parameters using different input values. Significance is shown for the following factors: Single‐use components in a reuse system Constant factors in a reuse system Pool size compared to system size in a reuse system Loss percentage With this method, several factors are taken up outside of LCA software in order to determine a break‐even point or to understand the trajectory of the system impact over rotations. Together with inventory reporting according to ISO 14040/14044 this can be the basis for transparent reuse system impact calculations and its fair comparison to single‐use system impact.

25 July 2026 in Packaging Technology and Science
Verified
Journal Article
Open access
IIIlknur Ilhan
Ilknur Ilhan
DBDaniel Sean Bezzina
Daniel Sean Bezzina
SGSilvia Gentiluomo
Silvia Gentiluomo
MVMax Vanhouttem
Max Vanhouttem
CACristina Ortiz Avila
Cristina Ortiz Avila
RKRoland Ten Klooster
Roland Ten Klooster
Adding recycled content is paramount for achieving circular packaging. However, packaging films produced from postindustry or postconsumer recycled polyethylene (PCR PE) have been reported to have various visual and mechanical issues related to impurities and degradation, which affect their performance. This paper studies the gel presence and seal characteristics of packaging films produced from 100% monolayer PCR PE with the addition of antioxidants and compatibilizers. It additionally evaluates the performance of commercially produced multilayer PE films that contain 30% and 50% PCR PE in the core layers and virgin sealant and top layers, checking the quality variations that arise from the difference in PCR PE batches. In the research, the presence and surface area ratio of gels related to recycled content are analyzed using FTIR, microscopy and a newly introduced image analysis method; seal performance is measured via hot‐tack and cold‐tack tests, and material performance is evaluated via tensile testing. According FTIR findings, some spherical and fibre like impurities coming from PCR PE were found to be polyamide or cellulose based, respectively. In nonfood contact commercial films with PCR PE content, the quality varied largely from batch to batch as well as the hot and cold seal strength. In 100% PCR PE films produced in laboratory settings, adding antioxidants during film production did not significantly influence the gel presence while one of the maleic anhydride‐based (MAH) compatibilizers used in the research reduced both the gel number (from 432 to 375 pcs/9 cm 2 ) and gel area ratio (from 0.81% to 0.67%). On the other hand, both types of additives delayed the breakage failure providing a larger operation window in hot‐tack tests. During the cold‐tack test, stronger attachment at the seal interphase is observed at 100°C sealing temperature in samples with added compatibilizer. Finally, according to tensile test results, the Young's modulus and the elongation at break only showed slight changes with the addition of antioxidants and compatibilizers. The results can be used for guidelines for design from recycling working with PE films.