Seyed-Hashem Daryabari

Seyed-Hashem Daryabari

Auto-generated profile, based on publicly available information

Seyed-Hashem Daryabari

Department of Ophthalmology, Baqiyatallah University of Medical Sciences, Tehran, Iran

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2021 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
SDSeyed Hashem Daryabari
Seyed Hashem Daryabari
AAAtieh Asadollah
Atieh Asadollah
FMFarhad Adhami Moghadam
Farhad Adhami Moghadam
RDRuhollah Dorostkar
Ruhollah Dorostkar
ABAli Bahramifar
Ali Bahramifar
HAHossein Aghamollaei
Hossein Aghamollaei

7 June 2018 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
SPShiva Pirhadi
Shiva Pirhadi
NMNeda Mohammadi
Neda Mohammadi
SMSeyed Aliasghar Mosavi
Seyed Aliasghar Mosavi
HDHashem Daryabari
Hashem Daryabari
HAHossein Aghamollaei
Hossein Aghamollaei
KJKhosrow Jadidi
Khosrow Jadidi
This paper seeks to evaluate the depth and outcomes of MyoRing implantation using two mechanical dissection procedures including: PocketMaker microkeratome in opposition to the Melles hook method. This retrospective study was carried out on 39 eyes of 38 keratoconus patients (28 male and 10 female) with the mean age of 28.97 + . 10.37 $$ 28.97\frac{+}{.}10.37 $$ years and had undergone MyoRing implantation by the two mentioned methods. The MyoRing was inserted into the corneal pocket which was made manually in 18 eyes (Melles hook group) or with PocketMaker microkeratome in 21 eyes (PocketMaker group). The mean follow up time was 9.81 + . 3.7 $$ 9.81\frac{+}{.}3.7 $$ months with pre-operative and post-operative ophthalmic examination including uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), keratometry readings and central corneal thickness measurement. AS-OCT (Casia, SS-1000, Tomey, Nagoya, Japan) imaging was used to measure MyoRing insertion depth, exactly. Pre-operative and post-operative UCVA (LogMAR) mean change for the PocketMaker and Melles hook groups were recorded at 0.75 ± 0.32 and 0.78 ± 0.33, respectively. Similarly, BCVA (LogMAR) mean change were 0.27 ± 0.22 and 0.23 ± 0.22. Mean keratometry (Kmean) change were 6.06 ± 4.18 and 6.56 ± 3.55 respectively. UCVA change (P = 0.767), BCVA change (P = 0.77) and Kmean change (P = 0.693) showed that there was no statistically significant difference between both groups for any parameter. Depth measurements achieved from AS-OCT images showed that there was no statistically significant difference in pocket depth between two methods of MyoRing implantation (P = 0.413). The results of Myoring implantation outcomes using mechanical dissection via PocketMaker microkeratome as against Melles hook are comparable.

7 June 2022 in Experimental Eye Research
Verified
Journal Article
Closed access
HYHasan Yousefi-Manesh
Hasan Yousefi-Manesh
HAHossein Aghamollaei
Hossein Aghamollaei
ADAhmad Reza Dehpour
Ahmad Reza Dehpour
MSMohammad Sheibani
Mohammad Sheibani
STSeyed Mohammad Tavangar
Seyed Mohammad Tavangar
TNTayebeh Noori
Tayebeh Noori

3 February 2026 in Disaster Medicine and Public Health Preparedness
Verified
Journal Article
Open access
SHSeyed Rahim Hassanpour
Seyed Rahim Hassanpour
VHValiallah Hosseinpour
Valiallah Hosseinpour
ASAlireza Shakerisefat
Alireza Shakerisefat
MAMahdi Moteshaker Arani
Mahdi Moteshaker Arani
SDSeyed-Hashem Daryabari
Seyed-Hashem Daryabari
HAHassan Abolghasemi
Hassan Abolghasemi
Background: On September 17, 2024, a coordinated detonation of approximately 5,000 pager devices in Lebanon produced a large mass-casualty incident. Devices contained pentaerythritol tetranitrate (PETN). We report 5 pediatric patients transferred to a tertiary referral center for management of complex multisystem injuries. Methods: We performed a brief report of 5 children (<12 years) referred to Baqiyatallah Hospital, Tehran. Demographics, injury pattern, surgical interventions, and short-term outcomes (up to 3 months) were abstracted from medical records. All patients received multidisciplinary care (ophthalmology, plastic surgery, orthopedics, otolaryngology, pediatrics, infectious disease). Results: Mean age was 9.2 years (range 5–11). All 5 children sustained ocular, facial, and hand injuries. Three eyes were auto-eviscerated, and 4 children underwent partial hand amputations. Multiple operative procedures were required per patient (ocular surgery, facial reconstruction, orthopedic fixation). Early outcomes were poor for vision and hand function in the majority; reconstructive planning and prosthetic rehabilitation were anticipated for longer-term care. Conclusion: Close-range exposure to small PETN-containing devices produced a distinctive pediatric injury pattern dominated by severe ocular and upper-extremity trauma. These findings emphasize the need for pediatric-focused acute care algorithms and sustained rehabilitation resources after blast incidents.

14 February 2025 in Eye
Verified
Journal Article
Closed access
SDSeyed-Hashem Daryabari
Seyed-Hashem Daryabari
SISeyyed Morteza Hosseini Imeni
Seyyed Morteza Hosseini Imeni
SHSeyyed Rahim Hassanpour
Seyyed Rahim Hassanpour

1 December 2025 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
SDSeyed Hashem Daryabari
Seyed Hashem Daryabari
SISeyyed Morteza Hosseini Imeni
Seyyed Morteza Hosseini Imeni
MGMojtaba Ghouhestani
Mojtaba Ghouhestani
Purpose: To evaluate the effect of suction direction on zonular fibers' mechanical behavior using finite element modeling. Setting: Laboratory study. Design: 3D finite element model experimental study. Methods: A 3D finite element model was developed, including nucleus covered by cortex and capsule. Similar to cataract surgery, a circular rapture was considered at the top of the capsule to apply suction pressure. Finally, zonular fibers were modeled as a continuum body using 3D solid elements (C3D8R). A custom FORTRAN subroutine was implemented to enforce tension-only behavior, mimicking the physiological characteristics of the zonular fibers, which are resistant to tensile but not compressive loads. This method allows for a realistic simulation of zonular mechanics during cortical aspiration. Results: The suction processes in tangential and normal angles were simulated. The resulting relative displacements between the cortex and capsule, as a criterion of cortex separation, vs the resulting maximum zonule displacements, were recorded in each model. The cortex–capsule relative displacement vs maximum zonule displacement indicated a diagram slope of 0.09 for tangential applying pressure and 0.02 in the case of applying normal pressure. Conclusions: The results illustrated that zonular fibers were less tensile in a specific magnitude of cortex–capsule relative displacement under tangential applying pressure, which means that eye zonular fibers have a lower risk of failure until the separation of the lens cortex.