Yan Gan

Yan Gan

Auto-generated profile, based on publicly available information

Yan Gan

Central China Branch of State Grid Corporation of China, Wuhan 430070, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2020 in IEEE Access
Verified
Journal Article
Open access
LZLi Zhang
Li Zhang
JRJiangjun Ruan
Jiangjun Ruan
ZDZhiye Du
Zhiye Du
WZWenfeng Zhou
Wenfeng Zhou
GLGuannan Li
Guannan Li
YGYan Gan
Yan Gan
Crustal movement and land subsidence will cause tower foundation settlement, which seriously affects the safety of transmission line operation. This paper proposed a short-term failure warning method for transmission tower under land subsidence condition based on finite element method, strain monitoring and time series prediction. By simulating the stress distribution of the tower in actual foundation settlement, the weak components of the settlement tower were founded. Combined with the finite element simulation results in various conditions, the reliability of simulation results is verified, and the strain variation range of the corresponding measuring point is obtained. By installing the real-time strain monitoring system and establishing the autoregressive integrated moving average (ARIMA) time series forecast model, warning of the failure of the tower can be sounded in short time according to the strain monitoring and forecasting results. The field results show that the tower is in good condition and with no risk in short term. The method proposed by this paper is economical and easy to operate, which can be used to conduct the emergency treatment of the dangerous tower under land subsidence condition.

25 May 2026 in Energies
Verified
Journal Article
Open access
PDF file
CZChuihui Zeng
Chuihui Zeng
YGYan Gan
Yan Gan
JWJun Wu
Jun Wu
BLBaolei Li
Baolei Li
JCJia Chen
Jia Chen
YFYaqi Fang
Yaqi Fang
High-capacity energy storage batteries contain complex physicochemical systems. The thermal runaway within batteries pose significant challenges to widespread application in energy storage systems. To better investigate the safety warning thresholds of battery energy storage systems, it is necessary to study the thermal runaway characteristics and behavioral patterns of batteries under various abusive conditions. This study focuses primarily on energy storage batteries in actual operation and on simulating real-world operating conditions. A multi-parameter experimental monitoring platform based on temperature, voltage, expansion force, and particulate matter concentration was established to investigate the multi-parameter variation patterns and distinctive characteristics of thermal runaway in energy storage cells under electrothermal coupling and overcharging abuse conditions. The results show that under electrothermal coupling conditions, the initial critical moment of thermal runaway occurs 530 s earlier than under overcharging conditions, with a maximum temperature reaching 457.2 °C; however, under overcharging conditions, the thermal runaway process is more severe, with a maximum temperature reaching 580.9 °C. A comparative analysis of the early warning thresholds for multiple parameters revealed that the threshold based on mechanical signals appears the earliest. Under electrothermal coupling conditions, the force signal preceded the injection valve signal, voltage signal, and temperature signal by 121 s, 305 s, and 732 s, respectively, with a maximum expansion force of 6836 N; under electrical abuse conditions, the force signal preceded the aforementioned signals by 458 s, 711 s, and 1733 s, respectively, with a maximum expansion force reaching 7566 N. This study provides a basis for the thermal management design and safety control of energy storage batteries. This study offers insights for safeguarding the proper operation of battery energy storage systems.

14 August 2023
Verified
Book Chapter
Closed access
PDF file
JHJingxuan He
Jingxuan He
YGYan Gan
Yan Gan
YYYong Yao
Yong Yao
SLShuang Liu
Shuang Liu
HCHongwei Cai
Hongwei Cai
ZDZhiye Du
Zhiye Du

26 April 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
GYGuohua Yue
Guohua Yue
ZDZhiye Du
Zhiye Du
GLGen Li
Gen Li
JHJingwen Huang
Jingwen Huang
Jiaxin YuanJiaxin Yuan
Jiaxin Yuan
YGYan Gan
Yan Gan
As an important indicator of the electromagnetic environment of UHVDC transmission lines, the ion flow field needs to be quickly calculated and updated in case to meet the requirement in building a digital twin of the power transmission system. This paper is based on the UFEM and starts from two aspects: electric field intensity convergence and charge density convergence. a) An adaptive iteration factor for charge density update is introduced, which can automatically control the iteration speed according to the change degree of electric field intensity, ensuring the rapid and stable update of charge density. b) On this basis, a half-error term is added to the charge density update formula. This controllable disturbance has little impact on the convergence of the charge density, but can greatly accelerate the convergence of the electric field intensity. Their combined effect greatly reduces the iteration steps required for the entire solution. A coaxial cylindrical model with analytical solutions and a real ± 800kV UHVDC transmission line project with test results are used to verify the method. In terms of accuracy, the numerical calculation results are exactly the same as the analytical solutions and are basically consistent with the test results. In terms of speed, compared with traditional fixed factors, after using the adaptive iteration factor, the iteration steps are reduced by up to 75%. In addition, after adding the half-error term, the iteration steps are further reduced by 32%. This method can strongly support the application of digital twin technology in power transmission.