Stephan William Anderson

Stephan William Anderson

Auto-generated profile, based on publicly available information

Stephan William Anderson

Photonics Center Boston University Boston MA 02215 USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2012 in Radiology
Verified
Journal Article
Closed access
JSJorge A. Soto
Jorge A. Soto
SAStephan W. Anderson
Stephan W. Anderson
The morbidity, mortality, and economic costs resulting from trauma in general, and blunt abdominal trauma in particular, are substantial. The "panscan" (computed tomographic [CT] examination of the head, neck, chest, abdomen, and pelvis) has become an essential element in the early evaluation and decision-making algorithm for hemodynamically stable patients who sustained abdominal trauma. CT has virtually replaced diagnostic peritoneal lavage for the detection of important injuries. Over the past decade, substantial hardware and software developments in CT technology, especially the introduction and refinement of multidetector scanners, have expanded the versatility of CT for examination of the polytrauma patient in multiple facets: higher spatial resolution, faster image acquisition and reconstruction, and improved patient safety (optimization of radiation delivery methods). In this article, the authors review the elements of multidetector CT technique that are currently relevant for evaluating blunt abdominal trauma and describe the most important CT signs of trauma in the various organs. Because conservative nonsurgical therapy is preferred for all but the most severe injuries affecting the solid viscera, the authors emphasize the CT findings that are indications for direct therapeutic intervention.

4 January 2019 in Physical Review B
Verified
Journal Article
Closed access
PDF file
RGReza Ghaffarivardavagh
Reza Ghaffarivardavagh
JNJacob Nikolajczyk
Jacob Nikolajczyk
SAStephan Anderson
Stephan Anderson
XZXin Zhang
Xin Zhang
Recently, with advances in acoustic metamaterial science, the possibility of sound attenuation using subwavelength structures, while maintaining permeability to air, has been demonstrated. However, the ongoing challenge addressed herein is the fact that among such air-permeable structures to date, the open area represents only small fraction of the overall area of the material. In the presented paper in order to address this challenge, we first demonstrate that a transversely placed bilayer medium with large degrees of contrast in the layers' acoustic properties exhibits an asymmetric transmission, similar to the Fano-like interference phenomenon. Next, we utilize this design methodology and propose a deep-subwavelength acoustic metasurface unit cell comprising nearly 60% open area for air passage, while serving as a high-performance selective sound silencer. Finally, the proposed unit-cell performance is validated experimentally, demonstrating a reduction in the transmitted acoustic energy of up to 94%. This ultra-open metamaterial design, leveraging a Fano-like interference, enables high-performance sound silencing in a design featuring a large degree of open area, which may find utility in applications in which highly efficient, air-permeable sound silencers are required, such as smart sound barriers, fan or engine noise reduction, among others.

10 April 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
RGReza Ghaffarivardavagh
Reza Ghaffarivardavagh
JNJacob Nikolajczyk
Jacob Nikolajczyk
RHR. Glynn Holt
R. Glynn Holt
SAStephan Anderson
Stephan Anderson
XZXin Zhang
Xin Zhang
Acoustic metasurfaces represent a family of planar wavefront-shaping devices garnering increasing attention due to their capacity for novel acoustic wave manipulation. By precisely tailoring the geometry of these engineered surfaces, the effective refractive index may be modulated and, consequently, acoustic phase delays tuned. Despite the successful demonstration of phase engineering using metasurfaces, amplitude modulation remains overlooked. Herein, we present a class of metasurfaces featuring a horn-like space-coiling structure, enabling acoustic control with simultaneous phase and amplitude modulation. The functionality of this class of metasurfaces, featuring a gradient in channel spacing, has been investigated theoretically and numerically and an equivalent model simplifying the structural behavior is presented. A metasurface featuring this geometry has been designed and its functionality in modifying acoustic radiation patterns experimentally validated. This class of acoustic metasurface provides an efficient design methodology enabling complete acoustic wave manipulation, which may find utility in applications including biomedical imaging, acoustic communication, and non-destructive testing.

26 March 2019 in Communications Physics
Verified
Journal Article
Open access
PDF file
GDGuangwu Duan
Guangwu Duan
XZXiaoguang Zhao
Xiaoguang Zhao
SAStephan William Anderson
Stephan William Anderson
XZXin Zhang
Xin Zhang
Magnetic resonance imaging (MRI) represents a mainstay among the diagnostic imaging tools in modern healthcare. Signal-to-noise ratio (SNR) represents a fundamental performance metric of MRI, the improvement of which may be translated into increased image resolution or decreased scan time. Recently, efforts towards the application of metamaterials in MRI have reported improvements in SNR through their capacity to interact with electromagnetic radiation. While promising, the reported applications of metamaterials to MRI remain impractical and fail to realize the full potential of these unique materials. Here, we report the development of a magnetic metamaterial enabling a marked boost in radio frequency field strength, ultimately yielding a dramatic increase in the SNR (~ 4.2×) of MRI. The application of the reported magnetic metamaterials in MRI has the potential for rapid clinical translation, offering marked enhancements in SNR, image resolution, and scan efficiency, thereby leading to an evolution of this diagnostic tool.

1 April 2007 in Radiology
Verified
Journal Article
Closed access
SAStephan W. Anderson
Stephan W. Anderson
JVJose C. Varghese
Jose C. Varghese
BLBrian C. Lucey
Brian C. Lucey
PBPeter A. Burke
Peter A. Burke
EHErwin F. Hirsch
Erwin F. Hirsch
JSJorge A. Soto
Jorge A. Soto
To retrospectively evaluate delayed-phase computed tomography (CT) in the differentiation of active splenic hemorrhage requiring emergent treatment from contained vascular injuries (pseudoaneurysms or arteriovenous fistulas) that can be treated electively or managed conservatively. The institutional review board approved this HIPAA-compliant retrospective study; the informed consent requirement was waived. Forty-seven patients with blunt splenic injury diagnosed at CT after blunt abdominal trauma were evaluated. Abdominal and pelvic dual-phase CT was performed; images were obtained 60-70 seconds and 5 minutes after contrast material injection. Scans were reviewed in consensus by two radiologists. Splenic injuries were graded with the American Association for the Surgery of Trauma Splenic Injury Scale. Patients with intrasplenic hyperattenuating foci on portal venous phase images were classified as having active splenic hemorrhage (group 1) or a contained vascular injury (group 2) on the basis of delayed-phase imaging findings. Findings suggestive of active hemorrhage included areas that remained hyperattenuating or increased in size on delayed-phase images. The clinical outcome of these patients was determined by reviewing their medical records. Relationships between several factors were tested with the Fisher exact test, including (a) the presence or absence of hyperattenuating foci and management and (b) the presence of contained vascular injury or active extravasation and management. Portal venous phase CT revealed a focal high-attenuation parenchymal contrast material collection in 19 patients: nine patients were classified as group 1 and 10 were classified as group 2. All patients in group 1 underwent emergent splenectomy, and all patients in group 2 were initially treated without surgery. Significant differences in management were noted on the basis of whether hyperattenuating foci were seen on portal venous phase images (P < .001) and whether hyperattenuating foci seen at portal venous phase imaging were further characterized as active splenic hemorrhage or a contained vascular injury at delayed-phase CT (P < .001). In blunt splenic injury, delayed-phase CT helps differentiate patients with active splenic hemorrhage from those with contained vascular injuries.

1 November 2009 in American Journal of Roentgenology
Verified
Journal Article
Closed access
SAStephan W. Anderson
Stephan W. Anderson
JSJorge A. Soto
Jorge A. Soto
BLBrian C. Lucey
Brian C. Lucey
Al OzonoffAl Ozonoff
Al Ozonoff
JJJacqueline D. Jordan
Jacqueline D. Jordan
JRJames T. Rhea
James T. Rhea
OBJECTIVE. The objective of our study was to compare the diagnostic accuracy of IV contrast-enhanced 64-MDCT with and without the use of oral contrast material in diagnosing appendicitis in patients with abdominal pain.MATERIALS AND METHODS. We conducted a randomized trial of a convenience sample of adult patients presenting to an urban academic emergency department with acute nontraumatic abdominal pain and clinical suspicion of appendicitis, diverticulitis, or small-bowel obstruction. Patients were enrolled between 8 am and 11 pm when research assistants were present. Consenting subjects were randomized into one of two groups: Group 1 subjects underwent 64-MDCT performed with oral and IV contrast media and group 2 subjects underwent 64-MDCT performed solely with IV contrast material. Three expert radiologists independently reviewed the CT examinations, evaluating for the presence of appendicitis. Each radiologist interpreted 202 examinations, ensuring that each examination was interpreted by two radiolo...