Mark A. Zinchenko

Mark A. Zinchenko

Auto-generated profile, based on publicly available information

Mark A. Zinchenko

Nosov Magnitogorsk State Technical University, Lenina Av. 38, Magnitogorsk, 455000, Russia

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Vadim R. GasiyarovVadim R. Gasiyarov
Vadim R. Gasiyarov
ARAndrey A. Radionov
Andrey A. Radionov
Boris LoginovBoris Loginov
Boris Loginov
MZMark A. Zinchenko
Mark A. Zinchenko
OGOlga A. Gasiyarova
Olga A. Gasiyarova
Vadim KhramshinVadim Khramshin
Vadim Khramshin
Creating digital twins of industrial equipment requires the development of adequate virtual models, and the calculation of their parameters is a complex scientific and practical problem. To configure and digitally commission automated drives, two-mass electromechanical system models are used. A promising area in which to implement such models is the development of digital shadows, namely drive position observers. Connecting virtual models for online data exchange predetermines the tightening of requirements for their parameter calculation accuracy. Therefore, developing accessible techniques for calculating electromechanical system coordinates is an urgent problem. These parameters are most accurately defined by experiments. The contribution of this paper is the proposition of a method for defining the two-mass system model parameters using the oscillograms obtained in the operating and emergency modes. The method is developed for the horizontal stand drives of a plate mill 5000 and is supported by numerical examples. The technique is universal and comprises calculating the rotating mass inertia torques, elastic stiffness and oscillation damping coefficients, and the time constants of the motor air gap torque control loop. The obtained results have been applied to the development of the elastic torque observer of the rolling stand’s electromechanical system. A satisfactory coordinate recovery accuracy has been approved for both open and closed angular gaps in mechanical joints. Recommendations are given for the use of the method in developing process parameter control algorithms based on automated drive position observers. This contributes to the development of the theory and practice of building digital control systems and the implementation of the Industry 4.0 concept in industrial companies.

1 January 2016 in Procedia Engineering
Verified
Journal Article
Open access
SES.A. Evdokimov
S.A. Evdokimov
YKYu.N. Kondrashova
Yu.N. Kondrashova
OKO.I. Karandaeva
O.I. Karandaeva
MGM.S. Gallyamova
M.S. Gallyamova
Implementation of stationary systems of continuous monitoring technical state of power transformers is considered to be an important and relevant task. The paper provides a summery on the systems implemented at transformers of OJSC Magnitogorsk Iron and Steel Works. It characterizes the transformer of the power generating set of the thermal power plant equipped with the system for monitoring technical state. It lists diagnostic methods and offers an integrated system structure. The monitoring system is based on TDM package developed by OAO Dimrus. As a device for oil condition control, the Hydran M2 analyzer identifying gases dissolved in oil was used. Functions of separate modules, their version and arrangements are under consideration. The system interface is characterized, too. The main screen of controlled parameter of the transformer is provided in Inva-format. There is a challenge to develop methods for fault localization and identification based on the total of diagnostic features. The paper highlights a practical need for investigation of discharge activity with portable devices for control of partial discharges.

17 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
SVStanislav S. Voronin
Stanislav S. Voronin
ARAndrey A. Radionov
Andrey A. Radionov
AKAlexander S. Karandaev
Alexander S. Karandaev
RLRoman A. Lisovsky
Roman A. Lisovsky
Boris LoginovBoris Loginov
Boris Loginov
IEIvan Nikolaevich Erdakov
Ivan Nikolaevich Erdakov
The problem of reducing electric power consumption is critical to ferrous metallurgy as it is a very energy-intensive industry. Significant energy savings can be achieved by increasing the efficiency of high-power electric drives of rolling mills. Experiments with the 5000 plate mill showed that the deterioration of energy efficiency can be caused by the misalignment of loads between the upper and lower roller main electric drive motors (upper main drive/UMD and lower main drive/LMD, respectively) caused by the misalignment of roller motor speeds. Experiments showed that when the speed misalignment reaches 5%, the motor torques differ by two times. Various UMD and LMD speeds can be set to bend the front end of the workpiece (form a “ski”). The installed load division controller (LDC) option fails to provide load alignment due to a low response rate and late startup. This article’s contribution consists of the development of a forced UMD and LMD speed and torque alignment method. To implement this method, a load-division controller with a switching structure has been developed. The authors also developed an efficiency and electric loss monitor and provided an experimental assessment of electric losses per one-pass and per sheet batch rolling cycle. The prospects of this research include the optimization of high-speed and high-load electric drive modes to reduce the energy costs of rolling and the development of an LDC based on fuzzy logic algorithms.

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
YKYu.N. Kondrashova
Yu.N. Kondrashova
RKR.R. Khramshin
R.R. Khramshin
ANA.A. Nikolaev
A.A. Nikolaev
GSG.V. Shurygina
G.V. Shurygina
It has been proven that the introduction of the systems for continuous control of the power transformer technical state predetermines the need for improvement of the methods for calculation of the thermal modes, insulation wear and remaining service life of the equipment. Disadvantages of the existing methods recommended by domestic and foreign regulatory documents are noted. It is appeared to be practically to consider parameters of the environment, thermal mode retention and non-linearity of the thermal characteristics. The structure of algorithm for calculating temperature charts according to the load parameters with regard to the influence of the above factors is proposed. The developed software is briefly specified, too. The ultimate purpose is to develop and study the improved model for thermal characteristic calculation designed for the systems of on-line monitoring transformer technical state.