Alejandra Fabian

Alejandra Fabian

Auto-generated profile, based on publicly available information

Alejandra Fabian

DNV GL, Arnhem, Netherlands

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
Tomi RoinilaTomi Roinila
Tomi Roinila
TMTuomas Messo
Tuomas Messo
RLRoni Luhtala
Roni Luhtala
RSRick Scharrenberg
Rick Scharrenberg
EJErik C. W. de Jong
Erik C. W. de Jong
YSYin Sun
Yin Sun
The operation of more electric aircraft is dependent on the embedded power grid. Therefore, the on-board power-distribution system must be reliable, having a high level of survivability, and promptly respond to any change in aircraft's operation. Recent studies have presented a number of frequency-response-based tools with which to analyze both single- and multiconverter systems. The methods can be efficiently applied for on-board system analysis, stability assessment, and adaptive control design. Most often, wideband measurement techniques have been applied to obtain the frequency response from a specific converter or a subsystem required for the analysis. In the methods, a broadband excitation such as a pseudorandom binary sequence (PRBS) is used as an external injection, and Fourier techniques are applied to extract the spectral information. This paper presents implementation techniques of the wideband methods using power-hardware-in-the-loop measurements based on OPAL-RT real-time simulator. The presented methods make it possible to modify the system characteristics, such as impedance behavior, in real time, thereby providing means for various stability and control design tools for on-board power distribution systems. Experimental measurements are shown from a high-power energy distribution system recently developed at DNV GL, Arnhem, The Netherlands.

6 August 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Open access
HAHenrik Alenius
Henrik Alenius
Tomi RoinilaTomi Roinila
Tomi Roinila
RLRoni Luhtala
Roni Luhtala
TMTuomas Messo
Tuomas Messo
ABAndrew Burstein
Andrew Burstein
AFAlejandra Fabian
Alejandra Fabian
Modern electric distribution systems typically contain several feedback-controlled parallel inverters that together form a complex power distribution system. Consequently, a number of issues related to stability arise due to interactions among multiple inverter subsystems. Recent studies have presented methods where the stability and other dynamic characteristics of a paralleled inverter system can be effectively analyzed using impedance measurements. This paper presents implementation techniques for a comprehensive online stability analysis of grid-connected paralleled inverters using power hardware-in-the-loop measurements based on an OPAL-RT real-time simulator. The analysis is based on simultaneous online measurements of current control loop gains of the inverters and the grid impedance, and aggregated terminal admittance measurements of the inverters. The analysis includes the measurement of the inverters’ aggregated output impedance, inverters’ loop gains, global minor loop gain, and grid impedance. The presented methods make it possible to rapidly evaluate the system on both global and local level in real time, thereby providing means for online stability monitoring or adaptive control of such systems. Experimental measurements are shown from a high-power energy distribution system recently developed at DNV GL, Arnhem, Netherlands.

12 July 2019 in Energies
Verified
Journal Article
Open access
PDF file
RLRoni Luhtala
Roni Luhtala
TMTuomas Messo
Tuomas Messo
Tomi RoinilaTomi Roinila
Tomi Roinila
HAHenrik Alenius
Henrik Alenius
EJErik de Jong
Erik de Jong
AFAlejandra Fabian
Alejandra Fabian
Grid impedance is an important parameter which affects the control performance of grid-connected power converters. Several methods already exist for optimizing the converter control system based on knowledge of grid impedance value. Grid impedance may change rapidly due to fault or disconnection of a transmission line. Therefore, online grid identification methods have been recently proposed to have up-to-date information about the grid impedance value. This is usually done by perturbing the converter output current and measuring the response in output voltage. However, any parallel converters connected to the same interface point will cause errors, since the measured current differs from the current that is flowing through the grid interface point. This paper points out challenges and errors in grid impedance identification, caused by parallel converters and their internal control functions, such as grid-voltage support. Experimental grid-impedance measurements are shown from the power hardware-in-the-loop setup developed at DNV-GL Flexible Power Grid Lab.

25 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
TMTuomas Messo
Tuomas Messo
RLRoni Luhtala
Roni Luhtala
Tomi RoinilaTomi Roinila
Tomi Roinila
EJErik de Jong
Erik de Jong
RSRick Scharrenberg
Rick Scharrenberg
AFAlejandra Fabian
Alejandra Fabian
AC microgrid is an attractive way to energize local loads due to remotely located renewable generation. The AC microgrid can conceptually comprise several grid-forming and grid-following power converters, renewable energy sources, energy storage and local loads. To study the microgrid dynamics, power-hardware-in-the-loop (PHIL)-based test setups are commonly used since they provide high flexibility and enable testing the performance of real converters. In a standard PHIL setup, different components of the AC microgrid exist as real commercial devices or electrical emulators or, alternatively, can be simulated using real-time simulators. For accurate, reliable and repeatable results, the PHIL-setup should be able to capture the dynamics of the microgrid loads and sources as accurately as possible. Several studies have shown how electrical machines, dynamic RLC loads, battery storages and photovoltaic and wind generators can be emulated in a PHIL setup. However, there are no studies discussing how a three-phase grid-following power converter with its internal control functions should be emulated, regardless of the fact that grid-following converters (e.g., photovoltaic and battery storage inverters) are the basic building blocks of AC microgrids. One could naturally use a real converter to represent such dynamic load. However, practical implementation of a real three-phase converter is much more challenging and requires special knowledge. To simplify the practical implementation of microgrid PHIL-studies, this paper demonstrates the use of a commercial high-bandwidth voltage amplifier as a dynamic three-phase power converter emulator. The dynamic performance of the PHIL setup is evaluated by identifying the small-signal impedance of the emulator with various control parameters and by time-domain step tests. The emulator is shown to yield the same impedance behavior as real three-phase converters. Thus, dynamic phenomena such as harmonic resonance in the AC microgrid can be studied in the presence of grid-following converters.