In this paper, two practical large cylindrical floating-roof tanks with diameters of 60 m and 100 m are selected as research objects. Wind pressures on the internal wall of tank shells under various liquid levels are carefully investigated by both experimental and numerical methods, especially those around the sealing device. It is found that computational fluid dynamics (CFD) simulation gives similar but generally greater results than wind tunnel tests (WTTs), and that wind pressures around the sealing device increase with the rise of liquid level. Geometrically nonlinear analyses (GNA) are then performed to figure out the variation of buckling behavior of tank shells with the liquid level. Two buckling modes are specified, featured by large buckles in the unstiffened region and local short-wave buckles in the stiffened region, respectively. Buckling loads are found to increase stepwise with the liquid level, with critical heights roughly calculated by positions of stiffening rings. Finally, recommendations on liquid levels maintained in strong wind conditions are given, considering the safety of both sealing devices and tank shells.
Building upon the analytical study of the structural configuration and prestress state of the drum-shaped quad-strut cable dome, we conducted further investigation into its structural configuration. By employing the nodal equilibrium equations to solve the prestress state analysis of the cable dome, we compared the effects of two different cable laying methods on the prestress state of the cable dome structure. These methods include equal length of the radial horizontal projection of the upper chord ridge cables and equal radial chord length of the upper chord ridge cables. The analysis results show that the radial length of the top chord and its corresponding radial horizontal projection length of the cable dome structure can effectively reflect the trend of the prestress state of the structural configuration. Furthermore, by using a rise-to-span ratio of 0.11 as a threshold, the cable dome configuration is categorized into the flat spheroidal structural configuration and the small hemispheroidal structural configuration. When the structure is analyzed using a small rise-to-span ratio, the difference in prestress calculations between the two structural configurations is found to be less than 10%. Additionally, the structure exhibits a more uniform distribution of prestress, with the prestress gradually increasing from the inner circle to the outer circle. However, when the rise-to-span ratio increases, the difference between the prestress calculation results of the two configurations also increases, emphasizing the need to deploy upper chord ridge cables based on equal radial chord lengths (arc lengths). The research presented in this paper provides a novel insight into the structural topological form and prestress state calculation of cable domes with this configuration.
20 July 2018 in Advances in Structural Engineering
Pretension deviation may cause stiffness degradation and overstress that can compromise the safety of tensile structures, which can be diagnosed by modal identification. This article presents modal tests on a 1:10 scaled model of a herringbone-ribbed cable dome structure. An optimal sensor placement scheme is proposed to observe the geometric stiffness change induced by pretension deviation. Based on the tests, different output-only modal identification techniques were implemented. A substructure strategy was adopted to overcome the limited measurement quantity and provide localized diagnoses. The experimental results show that operational modal analysis methods based on output-only data can effectively identify major modes of massive structures. The sensitivity of modal characteristics to pretension deviation is also evaluated via experimental comparisons, and modifications are implemented in an analytical finite element model to approximate the test model. The identified modal information can help locate stiffness degradation and thereby pretension loss in tensile structures. A modified modal strain energy method is proposed to detect pretension loss from decentralized testing and is verified by the test results.
A six-bar tetrahedral unit of a rhombic projection plane is a basic geometric invariable body with a simple configuration. A six-bar tetrahedral cylindrical lattice shell can be assembled by rhombic projection plane six-bar tetrahedral units with identical geometry sizes, which is conducive to standardized design, industrial production, and prefabricated construction. The popularization and application requirements of green architecture industry can also be met using such a shell. A model test of a six-bar tetrahedral cylindrical lattice shell was developed to simulate the practical application of the prefabricated structural system. A new type of joint for the prefabricated structure was proposed that is easy to assemble and is lightweight. A tridimensional fine-tuning bed jig was developed to ensure the manufacturing precision of the pre-made six-bar tetrahedral units. Stacking and transport of the units were practiced. The assembly process from units to the integral shell was conducted in an experimental hall; the result testified the advantages of easy stack, convenient transport, and highly efficient fabrication. The structural assembly errors of the shell were measured, and the measurement results verified the installation accuracy of the test model. This practical study lays the foundation for further engineering applications of six-bar tetrahedral cylindrical lattice shells.
8 March 2016 in Advances in Structural Engineering
A novel spherical lattice shell composed of six-bar tetrahedral units whose horizontal projections are quadrilaterals is proposed. The lattice shell provides an advantage in industrialized production and prefabricated construction by comprising a plurality of similarly shaped modular units. Kinematic analysis for the lattice shell, based on which several strengthening structures and joint rigidity arrangements are proposed, is carried out. The structural behavior of a basic structure of the lattice shell, whose chord and web members are designed as beam and bar elements, respectively, is studied systematically. Construction details of the nodal joints and six-bar tetrahedral modular units are suggested, followed by a discussion about the construction scheme. A tool called A-shaped installing frame is designed to realize the prefabricated construction without scaffold. A test model of 10-m span was built to verify the feasibility of the nodal joint construction as well as the prefabricated construction scheme.