Lvhui Lv

Dr. Lvhui Lv


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2024 in Thin-Walled Structures
Verified
Journal Article
Closed access
JZJiaming Zeng
Jiaming Zeng
LLLvhui Lv
Lvhui Lv
ZZZhongyi Zhu
Zhongyi Zhu
SDShilin Dong
Shilin Dong
Yao-Peng LiuYao-Peng Liu
Yao-Peng Liu
LSLian Shao
Lian Shao

23 March 2025 in Buildings
Verified
Journal Article
Open access
PDF file
DYDan Yang
Dan Yang
XRXiaopeng Ren
Xiaopeng Ren
YGYongtao Gao
Yongtao Gao
TFTao Fan
Tao Fan
MLMingshuai Li
Mingshuai Li
LLLvhui Lv
Lvhui Lv
The increasing incidence of urban fires poses significant threats to structural integrity, underscoring the urgent need for concrete materials with enhanced mechanical properties post-fire. Incorporating recycled waste steel fibers (WSF) from industrial byproducts into concrete not only bolsters its crack resistance but also advances circular economy principles by transforming industrial waste into valuable resources. Although a large amount of research has focused on native steel fiber-reinforced concrete, there is still a lack of systematic exploration on the optimal dosage and effectiveness of waste steel fibers in slowing down the strength degradation of concrete after high-temperature action. In this study, two grades of concrete (C40 and C60) containing 0%, 1%, and 2% WSF by volume were subjected to heating cycles ranging from 200 °C to 800 °C. Post-cooling evaluations encompassed mass loss quantification, cube compressive strength testing (using 100 mm3 specimens), and splitting tensile tests conducted at a loading rate of 0.1 MPa/s. Results indicated that mass loss escalated to 11% at 800 °C, with C60 experiencing a 12% higher loss compared to C40. Compressive strength decreased by 15% for every 200 °C increment; however, the inclusion of 1% WSF significantly minimized this degradation, preserving 44.5% (for C40) and 37.8% (for C60) of the original strength at 800 °C. Notably, the splitting tensile strength of 1% WSF-reinforced C60 concrete exceeded that of plain concrete by 39.4% after exposure to 800 °C, demonstrating its superior crack-bridging capabilities.

10 January 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LLLvhui Lv
Lvhui Lv
ZCZhaoquan Chen
Zhaoquan Chen
SDShilin Dong
Shilin Dong
ZZZhongyi Zhu
Zhongyi Zhu
XXXin Xie
Xin Xie
YZYanfen Zhong
Yanfen Zhong
Building upon the analytical study of the structural configuration and prestress state of the drum-shaped quad-strut cable dome, we conducted further investigation into its structural configuration. By employing the nodal equilibrium equations to solve the prestress state analysis of the cable dome, we compared the effects of two different cable laying methods on the prestress state of the cable dome structure. These methods include equal length of the radial horizontal projection of the upper chord ridge cables and equal radial chord length of the upper chord ridge cables. The analysis results show that the radial length of the top chord and its corresponding radial horizontal projection length of the cable dome structure can effectively reflect the trend of the prestress state of the structural configuration. Furthermore, by using a rise-to-span ratio of 0.11 as a threshold, the cable dome configuration is categorized into the flat spheroidal structural configuration and the small hemispheroidal structural configuration. When the structure is analyzed using a small rise-to-span ratio, the difference in prestress calculations between the two structural configurations is found to be less than 10%. Additionally, the structure exhibits a more uniform distribution of prestress, with the prestress gradually increasing from the inner circle to the outer circle. However, when the rise-to-span ratio increases, the difference between the prestress calculation results of the two configurations also increases, emphasizing the need to deploy upper chord ridge cables based on equal radial chord lengths (arc lengths). The research presented in this paper provides a novel insight into the structural topological form and prestress state calculation of cable domes with this configuration.

26 July 2023 in Buildings
Verified
Journal Article
Open access
PDF file
HZHao Zhang
Hao Zhang
LLLvhui Lv
Lvhui Lv
ZZZhongyi Zhu
Zhongyi Zhu
ZCZhaoquan Chen
Zhaoquan Chen
YCYiyi Chu
Yiyi Chu
The drum-shaped honeycomb-type cable dome departs from traditional concepts and incorporates the idea of multiple strut configurations. It is the most diverse type of cable dome structure. Both cables and struts serve as the main load-bearing components. Analyzing the effects of local component failure is crucial for designing large-scale cable domes able to resist continuous collapse. A numerical analysis model using the ANSYS finite element method with a 120 m span is established. Dynamic analysis methods are employed to study the response of structural internal forces and displacements during the failure of different component types. By defining the internal force dynamic coefficient and change coefficient, the structural continuity collapse resulting from component failure is determined based on computational results and observation of structural deformations. Furthermore, the importance of the various components within the overall structure is classified. The research findings indicate that the failure of individual components does not cause overall instability of the structure. The importance level of the ring cables and some upper chord ridge cables is higher than that of the inclined cables. Class a struts have a higher importance level than class b struts. Additionally, the importance level of outer ring components is higher than that of inner ring components.

7 February 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LLLvhui Lv
Lvhui Lv
DLDewang Liu
Dewang Liu
LSLian Shao
Lian Shao
Yao-Peng LiuYao-Peng Liu
Yao-Peng Liu
ZZZhongyi Zhu
Zhongyi Zhu
YZYanfen Zhong
Yanfen Zhong
Previous research has confirmed that the newly proposed pentagonal three–four strut hybrid cable dome exhibits superior static performance compared to traditional cable domes, though its dynamic characteristics still require further study. Cable domes are wind-sensitive structures, and the results of a wind-induced vibration analysis are beneficial for the selection and construction of cable domes. In this study, a finite element model of a new open-type cable dome with a span of 120 m is established. The MATLAB 2017a programming language is employed to simulate pulsating winds, followed by a nonlinear dynamic analysis to analyze the wind-induced vibrations of the structure. The reliability of the pulsating wind model is confirmed by comparing the simulated spectrum with the target spectrum. Moreover, a wind-induced vibration time history analysis is performed to obtain the node displacement and internal force of components wind vibration coefficients, aiding in the approximation of pulsating winds with average winds in a wind-resistant design. Furthermore, a parametric analysis is carried out, ranking nodes and components based on sensitivity. The result shows that the structure exhibits the strongest wind resistance when the rise–span ratio is f/l=0.07 and the thickness–span ratio is h/l=0.08. Notably, the outer upper chord node, 2a, and the inner lower chord hoop cable, H1, are identified as the most sensitive node and component within the structure, respectively. Overall, the structure demonstrates excellent wind resistance performance, and the maximum wind vibration coefficient value remains below 3.

5 December 2024 in Thin-Walled Structures
Verified
Journal Article
Closed access
LLLvhui Lv
Lvhui Lv
LYLu Yi
Lu Yi
ZZZhongyi Zhu
Zhongyi Zhu
SDShilin Dong
Shilin Dong
LSLian Shao
Lian Shao
XWXiaoshun Wu
Xiaoshun Wu