Celso Costa

Celso Costa

Auto-generated profile, based on publicly available information

Celso Costa

Ophthalmology Department Hospitais da Universidade de Coimbra (HUC), ULS Coimbra Coimbra Portugal

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017
Verified
Conference Paper
Closed access
FAFelipe D'Agostini Arcari
Felipe D'Agostini Arcari
CCCelso Costa
Celso Costa
CPCarlos Eduardo Pereira
Carlos Eduardo Pereira
JNJoao Cesar Netto
Joao Cesar Netto
GTGuilherme Torres
Guilherme Torres
IMIvan Muller
Ivan Muller
Wireless Sensor Networks present several advantages when compared to wired ones, among them, the low consumption and simplicity of installation. In some cases, energy consumption may be so low as to allow the use of energy harvesting techniques, as in the case of EnOcean protocol. In other networks, it is necessary to meet specific requirements, such as in industrial ones, where communication must be robust, deterministic and safe. This is achieved by WirelessHART protocol. Both types of networks have limitations, such as EnOcean's inability to determinism and low dynamics of joining and maintenance of WirelessHART. This work presents a proposal to minimize these limitations, through the union of these networks, by the development of an WirelessHART - EnOcean adapter. The adapter adds the functionality of intermittent and battery-free sensors to a WirelessHART network in order to provide the use of EnOcean devices in industrial environments. Aiming the validation of the adapter, a case study is proposed where the functionality of both networks is verified. For the development of the proposal, hardware and firmware changes are made to a WirelessHART device and the development of hardware adapter and an application to integrate both networks.

24 December 2024 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
CCCelso Costa
Celso Costa
RORenato souza oliveira
Renato souza oliveira
JGJoão Gil
João Gil
ECEsmeralda Costa
Esmeralda Costa
CTCristina Tavares
Cristina Tavares
JMJoaquim Murta
Joaquim Murta
Introduction: Keratoconus patients turn to the internet for answers to their disease expectations. Webpages are not filtered or submitted to evaluation before getting published. We aim to evaluate the quality and readability of the online information regarding keratoconus in Portugal and Brazil. Methods: Two independent ophthalmologists and one ophthalmologist supervisor evaluated 30 Portuguese and 30 Brazilian websites by order of appearance in Google with the word “Queratocone” and “Ceratocone”, respectively. Two quality scores were used: a quality index of consumer health information (DISCERN) and the Journal of the American Medical Association (JAMA) benchmark. Readability was evaluated with 3 scores: FleschKincaid Reading Ease (FRE), FleschKincaid Grade (FKG) and Automated Readability Index (ARI). Results: Sites from private hospitals or clinics were the most prevalent in both countries, followed by health platform sites. Final JAMA benchmark was 1.13 ± 1.18 in Portugal and 1.07 ± 1.00 in Brazil. Final DISCERN was 34.07 ± 11.71 in Portugal and 38.17 ± 10.51 in Brazil. FRE and FKG scores denoted “difficult to read” and “college school level” in both countries; ARI denoted “professor” level in Portugal and “college student” level in Brazil needed to understand the text, a statistically significant difference. There was no correlation between Google ranking and quality and readability scores. Discussion and Conclusions: The information on keratoconus available online to Portuguese-speaking patients is of poor quality and difficult to interpret. Ophthalmologists have a shared responsibility to tackle this challenge through multifold efforts. Educating our patients on how to find reputable websites can help them navigate their life with keratoconus.

21 February 2025 in Acta Ophthalmologica
Verified
Journal Article
Closed access
CNCarlos Nogueira
Carlos Nogueira
CCCelso Costa
Celso Costa
VKVasil Kostin
Vasil Kostin
RSRufino Silva
Rufino Silva
JMJoaquim Murta
Joaquim Murta
JMJoão Pedro Marques
João Pedro Marques

10 November 2025 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
CCCelso Costa
Celso Costa
TCTelmo Cortinhal
Telmo Cortinhal
IFInês Figueiredo
Inês Figueiredo
MSMaria Silva
Maria Silva
MRMiguel Raimundo
Miguel Raimundo
JMJoaquim Murta
Joaquim Murta
Purpose: To report clinical (visual and refractive), spectacle independence, patient-reported outcomes following bilateral sequential implantation of a non-diffractive extended-vision intraocular lens (IOL): AcrySof IQ Vivity (DFT015 and DFTx15) in cataract surgery. This IOL provides continuous range of focus from distance to near, offering monofocal quality distance image and visual disturbances profile. Methods: Retrospective unmasked nonrandomized case series. Patients who underwent phacoemulsification and bilateral sequential implantation of AcrySof IQ Vivity, targeting minimonovision (nondominant eye targeted for between −0.25D and −0.50D). Clinical post-operative outcome measures were assessed 1–2 months postoperatively - binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity – 66 cm (UIVA), binocular uncorrected near visual acuity – 40 cm (UNVA), refraction, spherical equivalent (SE) and residual astigmatism (toric group). Spectacle independence and satisfaction systematic questionnaires (IOLSAT and Catquest-9SF) were performed. Visual disturbances were analyzed. Results: 181 patients were enrolled. 78 eyes were implanted with the DFTx15 (toric version). Binocular mean UDVA was −0.01 logMAR (± 0.05), binocular mean UIVA was 0.09 logMAR (± 0.08), binocular mean UNVA was 0.16 logMAR (± 0.12) and mean SE was −0.27D (± 0.36D). Mean residual astigmatism (toric group) was 0.3D (± 0.42D). Patient-reported outcomes for satisfaction and spectacle independence were excellent. Visual disturbances were rarely reported. Conclusions: Implanting this IOL using minimonovision strategy provides excellent binocular UDVA and UIVA, and good UNVA. It provides high patient satisfaction, spectacle independence (demonstrated excellent performance in systematic evaluations) and minimizes unwanted visual effects. Controlled designs and longer follow-ups are needed to confirm these findings.

10 March 2025 in International Journal of Retina and Vitreous
Verified
Journal Article
Open access
PDF file
CCCelso Costa
Celso Costa
NGNuno Gouveia
Nuno Gouveia
PFPedro Fonseca
Pedro Fonseca
MRMiguel Raimundo
Miguel Raimundo
JMJoaquim Murta
Joaquim Murta
JFJoão Figueira
João Figueira
Purpose: This paper presents a modification of the needle-assisted retropupillary fixation technique for iris-claw intraocular lenses (IOLs). We introduce a novel, minimally invasive reenclavation technique for managing subluxated retropupillary iris-claw IOLs. Methods: The technique was successfully performed on four patients diagnosed with subluxated retropupillary iris-claw IOLs. This approach involved a novel, minimally invasive reenclavation technique that utilized three needles: one long, straight translimbal needle crossing the anterior chamber and two needles introduced through the pars plana to reposition and securely reenclavate the IOL. Results: All patients experienced immediate and significant visual recovery, with their baseline visual acuities reestablished postoperatively. Importantly, no post-operative complications were observed during the six-month follow-up period, highlighting the safety and efficacy of the technique. Conclusion: Our novel, minimally invasive technique for reenclavation of iris-claw IOLs, employing just three needles, eliminates the need for trocar insertion, infusion cannulas, or sutures. This approach offers significant advantages, including a shorter operative time and minimal surgical manipulation, leading to faster patient recovery and fewer complications.