Clay J. Naito

Clay J. Naito

Auto-generated profile, based on publicly available information

Clay J. Naito

Lehigh Univ

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Journal of Structural Engineering
Verified
Journal Article
Closed access
CNClay Naito
Clay Naito
JHJohn Hoemann
John Hoemann
MBMark Beacraft
Mark Beacraft
BBBryan Bewick
Bryan Bewick
Insulated precast concrete sandwich wall panels are commonly used for exterior cladding on building structures. The insulation is sandwiched between exterior and interior concrete layers to reduce the heating and cooling costs for the structure. The panels can be designed as composite, partially composite, or noncomposite. Shear ties are used to achieve these varying degrees of composite action between the interior and exterior concrete layers. A variety of shear ties are available for domestic construction. An experimental study was conducted to assess the relative strength and response of these commercially available ties. Fourteen different shear tie types were examined, the failure modes and responses were quantified, and simplified engineer level multilinear strength curves were developed for each connection. The test results indicate that shear ties used in sandwich wall construction have considerable variation in strength, stiffness, and deformability. The maximum shear strength of the discrete tie...

1 March 2014 in Journal of Waterway, Port, Coastal, and Ocean Engineering
Verified
Journal Article
Closed access
CNClay Naito
Clay Naito
CCChristina Cercone
Christina Cercone
HRH. R. Riggs
H. R. Riggs
DCDaniel Cox
Daniel Cox

1 October 2014 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
CNClay Naito
Clay Naito
JSJoe States
Joe States
CJChristopher Jackson
Christopher Jackson
BBBryan Bewick
Bryan Bewick

1 July 2010 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
CNClay Naito
Clay Naito
RSRichard Sause
Richard Sause
IHIan Hodgson
Ian Hodgson
SPStephen Pessiki
Stephen Pessiki
TMThomas Macioce
Thomas Macioce
On the evening of December 27, 2005 the fascia beam supporting the east side parapet wall of the third span of the Lake View Drive Bridge failed under the action of dead load. To gain insight into the potential causes of the failure a series of forensic analyses were conducted on the beams decommissioned from the bridge. The study correlates external observations of surface condition with internal chloride profile, depth of carbonation, and existing corrosion. The forensic investigation indicated that strand cover was reduced due to the construction methods of the time. The chloride level in the concrete at the lower layer of strands was high enough that corrosion would be expected. Chloride attack was identified to have come from the leakage of water between beams from the bridge deck surface above. Based on the research findings recommendations are made for visual inspection, and guidelines are provided for condition rating of noncomposite prestressed concrete box beam bridges.

1 May 2015 in Journal of Waterway, Port, Coastal, and Ocean Engineering
Verified
Journal Article
Closed access
HKH. T.-S. Ko
H. T.-S. Ko
DCD. T. Cox
D. T. Cox
HRH. R. Riggs
H. R. Riggs
CNC. J. Naito
C. J. Naito

1 May 2014 in Journal of Structural Engineering
Verified
Journal Article
Closed access
PAP. Piran Aghl
P. Piran Aghl
CNC. J. Naito
C. J. Naito
HRH. R. Riggs
H. R. Riggs