Ilija Klasnić

Ilija Klasnić

Auto-generated profile, based on publicly available information

Ilija Klasnić

Univerzitet u Beogradu Elektrotehnički institut Nikola Tesla Koste Glavinića 8a 11000 Beograd Srbija

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Thermal Science
Verified
Journal Article
Open access
PDF file
IKIlija Klasnic
Ilija Klasnic
JDJasna Dragosavac
Jasna Dragosavac
ZLZoran Lazarevic
Zoran Lazarevic
A new monitoring method for determination of average hydrogenerator field winding temperature is introduced in order to increase the robustness of the temperature measurement system using the classic U-I method. The classic approach is prone to error due to brush voltage drop, especially when field voltage is low. Developed thermal model is based on field current and cold cooling air temperature measurements, as well on temperatures acquired from digital temperature sensors mounted across the field winding. To monitor the rotor temperature for generators with brushless excitation where field voltage and current measurements are not accessible, a mathematical model was developed to estimate the average field winding temperature based on the existing temperature monitoring of the cooling medium and mounted sensors. Importance of the proposed approach arises from the foreseen widespread use of brushless generators in distributed generation. The developed models were compared and their sensitivity was examined thoroughly.

1 January 2025 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
JDJasna Dragosavac
Jasna Dragosavac
ŽJŽarko Janda
Žarko Janda
AMAnita Mijajlović
Anita Mijajlović
IKIlija Klasnić
Ilija Klasnić
This paper presents a methodology for evaluating the voltage–reactive power capability of synchronous generators following changes in transformer impedance. The framework integrates per-unit calculations, an equivalent generator–transformer model, and numerical simulations across multiple grid-voltage scenarios. The SIM-Operating Map application provides analytical and graphical verification of reactive margins, limiting factors, and grid-code compliance, supporting operational decision-making and enhancing system security after transformer replacement.

1 January 2025 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
JDJasna Dragosavac
Jasna Dragosavac
AMAnita Mijajlović
Anita Mijajlović
IKIlija Klasnić
Ilija Klasnić
MĐMilan Đorđević
Milan Đorđević
IDIgor Damjanac
Igor Damjanac
MBMiloš Brdarević
Miloš Brdarević
Increasing integration of renewable energy sources and the withdrawal of fossil-fuel generators reduce overall power-system inertia, making the grid more vulnerable to disturbances and threatening transient and frequency stability. Low inertia can lead to large frequency deviations, equipment damage, and financial losses, which highlights the need for accurate assessment of inertia contributions from remaining generation units and determination of the minimum inertia required for stable operation. While synchronous generator inertia constants are usually provided by manufacturers, corresponding data for steam turbines are often unavailable. Since post-fault transient stability depends on the true inertia of the combined generator-turbine assembly, this gap complicates stability studies. This paper proposes a method for estimating the inertia of turbogenerators using coast-down measurements from thermal unit B1 of the "Nikola Tesla B" power plant. The method is based on Newton's rotational motion equation and enables more accurate evaluation of inertia in large thermal units.

1 January 2023 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
PDF file
DJDušan Joksimović
Dušan Joksimović
DSdjordje stojic
djordje stojic
SVSlavko Veinović
Slavko Veinović
LILuka Ivanović
Luka Ivanović
IKIlija Klasnić
Ilija Klasnić
NMNemanja Milojčić
Nemanja Milojčić
This paper presents a method for selecting parameters and analyzing the dynamic characteristics of a under-excitation excitation limiter using a computer model. The parameters are determined using the pole cancellation method for the worst-case operating regime from the perspective of the under-excitation limiter to ensure stability in all operating regimes. The analysis of the dynamic characteristics presented in the paper first obtained the time responses and frequency characteristics of the excitation control system when the limiter is active. Based on these, the values of dynamic performance indicies that indicate the quality of regulation are determined. The paper also provides a brief description of the implementation of the limiter and the computer models used in the analysis.

1 January 2023
Verified
Conference Paper
Closed access
ZRZdravko Ristić
Zdravko Ristić
ESElectrodistibution Of Serbia
Electrodistibution Of Serbia
IJIvan Jagodić
Ivan Jagodić
IKIlija Klasnić
Ilija Klasnić
UKUroš Kovačević
Uroš Kovačević
MRMihajlo Ristić
Mihajlo Ristić

1 January 2025
Verified
Conference Paper
Closed access
UTUniverzitet u Beogradu Elektrotehnički institut Nikola Tesla
Univerzitet u Beogradu Elektrotehnički institut Nikola Tesla
ŽJŽarko Janda
Žarko Janda
JDJasna Dragosavac
Jasna Dragosavac
IKIlija Klasnić
Ilija Klasnić
AMAnita Mijajlović
Anita Mijajlović
MBMiloš Brdarević
Miloš Brdarević
In a conventional power system structure, synchronous generators provide transient and frequency stability due to the kinetic energy of rotating masses. Increased penetration of renewable energy sources and the gradual shift towards the green agenda result in the shutdown of existing power generation units that rely on fossil fuels, making the system more susceptible to disturbances due to a lack of inertia. Problems that arise in a system facing a lack of inertia can lead to significant financial losses, so it is crucial to assess the amount of inertia provided by the existing units in power plants and determine the minimum critical inertia value that the system should always have. For conventional power generation units, the inertia data of the generator is one of the parameters that can be found in the technical documentation of the generator. However, it is not possible to obtain the same data for turbines, especially for steam turbines. This paper presents a method for calculating the inertia of turbo generators based on the stop recordings of thermal block B1 in the „Nikola Tesla B“ power plant, starting from Newton’s equation of rotational motion, with the aim of contributing to a better understanding of the overall inertia of the system.