Ziwei Yan

Ziwei Yan

Auto-generated profile, based on publicly available information

Ziwei Yan

College of Information Science and Engineering, Xinjiang University, Urumqi, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2021 in IEEE Access
Verified
Journal Article
Open access
MLMin Li
Min Li
XMXiaojian Ma
Xiaojian Ma
YYYushuai Yuan
Yushuai Yuan
SZShuailei Zhang
Shuailei Zhang
ZYZiwei Yan
Ziwei Yan
MMMingrui Ma
Mingrui Ma
Lung cancer (LC) is one of the most serious cancers threatening human health. Histopathological examination is the gold standard for qualitative and clinical staging of lung tumors. However, the process for doctors to examine thousands of histopathological images is very cumbersome, especially for doctors with less experience. Therefore, objective pathological diagnosis results can effectively help doctors choose the most appropriate treatment mode, thereby improving the survival rate of patients. For the current problem of incomplete experimental subjects in the computer-aided diagnosis of lung cancer subtypes, this study included relatively rare lung adenosquamous carcinoma (ASC) samples for the first time, and proposed a computer-aided diagnosis method based on histopathological images of ASC, lung squamous cell carcinoma (LUSC) and small cell lung carcinoma (SCLC). Firstly, the multidimensional features of 121 LC histopathological images were extracted, and then the relevant features (Relief) algorithm was used for feature selection. The support vector machines (SVMs) classifier was used to classify LC subtypes, and the receiver operating characteristic (ROC) curve and area under the curve (AUC) were used to make it more intuitive evaluate the generalization ability of the classifier. Finally, through a horizontal comparison with a variety of mainstream classification models, experiments show that the classification effect achieved by the Relief-SVM model is the best. The LUSC-ASC classification accuracy was 73.91%, the LUSC-SCLC classification accuracy was 83.91% and the ASC-SCLC classification accuracy was 73.67%. Our experimental results verify the potential of the auxiliary diagnosis model constructed by machine learning (ML) in the diagnosis of LC.

30 July 2020 in IEEE Access
Verified
Journal Article
Open access
MLMin Li
Min Li
XNXiaohan Nie
Xiaohan Nie
YRYilidan Reheman
Yilidan Reheman
PHPan Huang
Pan Huang
SZShuailei Zhang
Shuailei Zhang
WHWei Han
Wei Han
Pancreatic cancer (PC) is a malignant tumor that seriously threatens the survival of patients. Artificial classification has practical difficulties, such as unstable classification accuracy, a heavy workload, and the classification results depend on the subjective judgment of the clinician during the diagnosis and staging of PC. In addition, accurate PC staging could better help clinicians deliver the optimal therapeutic schedule for PC patients of different stages. Therefore, this study proposes a comprehensive medical computer-aided method for preoperative diagnosis and staging of PC based on an ensemble learning-support vector machine (EL-SVM) and computed tomography (CT) images. The least absolute shrinkage and selection operator (LASSO) algorithm was chosen for feature selection. In contrast to no feature selection, the model optimization time decreased by 19.94 seconds while maintaining precision. The EL-SVM learner was used to classify 168 CT images of normal pancreas and different stages of PC. The experimental results demonstrated that the normal pancreas (normal)-pancreatic cancer early stage (early stage) classification accuracy was 86.61%, the normal-pancreatic cancer stage III (stage III) classification accuracy was 87.04%, the normal-pancreatic cancer stage IV (stage IV) classification accuracy was 91.63%, the normal-PC classification accuracy was 87.89%, the early stage-stage III classification accuracy was 75.03%, and the early stage-stage IV classification accuracy was 81.22%, and the stage III-stage IV classification accuracy was 82.48%. Our experimental results prove that our proposed method is feasible and promising for clinical applications for the preoperative diagnosis and staging of PC via CT images.

27 January 2022 in Journal of Raman Spectroscopy
Verified
Journal Article
Closed access
PDF file
XTXuecong Tian
Xuecong Tian
CCCheng Chen
Cheng Chen
CCChen Chen
Chen Chen
ZYZiwei Yan
Ziwei Yan
WWWei Wu
Wei Wu
XLXiaoyi Lv
Xiaoyi Lv

24 March 2021 in IEEE Access
Verified
Journal Article
Open access
SZShuailei Zhang
Shuailei Zhang
CCCheng Chen
Cheng Chen
FCFangfang Chen
Fangfang Chen
MLMin Li
Min Li
BYBo Yang
Bo Yang
XLXiaoyi Lv
Xiaoyi Lv
Cervical cancer is a malignant tumor that threatens women's health and life. Cervical pathology examination, as the gold standard for cervical cancer diagnosis, provides an important basis for the surgical plan and postoperative follow-up strategy for cervical cancer. Cervical biopsy diagnosis includes normal, low-grade squamous intraepithelial lesion (LSIL), high-grade squamous intraepithelial lesion (HSIL) and squamous cell carcinoma (SCC). At present, cervical pathology examination still relies on the doctor's personal clinical experience and subjective judgment, which is time-consuming and may cause misdiagnosis or missed diagnosis. In addition, the current intelligent classification of cervical pathological images still has disadvantages such as imperfect classification system and low classification accuracy. Therefore, this experiment uses the ResNet50 model of the convolutional neural network as the feature extractor, and selects the K-Nearest Neighbour (KNN), Random Forest (RF), Support Vector Machine (SVM) classifiers in Machine Learning to perform cervical tissue pathological images Discrimination, the accuracy of the classification results were 85.83%, 80.33%, and 86.67%. In order to further improve the accuracy of the model and enhance the applicability and stability of the model, this experiment proposes the Stacked Generalization (SK) classification model. The first-layer base learner of the SK classification model selects CNN-KNN, CNN-RF, CNN-SVM, and the second-layer classifier selects Multilayer Perceptron (MLP). Among them, MLP makes the final result by learning the classification performance of the base learner for label discrimination, the accuracy of the classification model after ensemble learning is 90.00%. In addition, this experiment uses the Synthetic Minority Oversampling Technique (SMOTE) algorithm to amplify the training samples, and the amplified data set has a classification accuracy of 89.17% under the training of the SK classification model. The results show that the SK classification model in this experiment has a high classification ability for cervical histopathological images, and has good generalization ability and robustness.

1 December 2020 in Optik
Verified
Journal Article
Closed access
LMLing Ma
Ling Ma
RGRui Gao
Rui Gao
HHHuijie Han
Huijie Han
CCCheng Chen
Cheng Chen
ZYZiwei Yan
Ziwei Yan
LXLirong Xie
Lirong Xie

9 September 2020 in Journal of Spectroscopy
Verified
Journal Article
Open access
PDF file
YYYushuai Yuan
Yushuai Yuan
LYLi Yang
Li Yang
RGRui Gao
Rui Gao
CCCheng Chen
Cheng Chen
MLMin Li
Min Li
ZYZiwei Yan
Ziwei Yan
Chronic renal failure (CRF) is a clinically serious kidney disease. If the patient is not treated in a timely manner, CRF will develop into uremia. However, current diagnostic methods, such as routine blood examinations and medical imaging, have low sensitivity. Therefore, it is important to explore new and effective diagnostic methods for CRF, such as serum spectroscopy. This study proposes a cost-effective and reliable method for detecting CRF based on Fourier transform infrared (FT-IR) spectroscopy and a support vector machine (SVM) algorithm. We measured and analyzed the FT-IR spectra of serum from 44 patients with CRF and 54 individuals with normal renal function. The partial least squares (PLS) algorithm was applied to reduce the dimensionality of the high-dimensional spectral data. The samples were input into the SVM after division by the Kennard–Stone (KS) algorithm. Compared with other models, the SVM optimized by a grid search (GS) algorithm performed the best. The sensitivity of our diagnostic model was 93.75%, the specificity was 100%, and the accuracy was 96.97%. The results demonstrate that FT-IR spectroscopy combined with a pattern recognition algorithm has great potential in screening patients with CRF.