Xu Xu

Xu Xu

Auto-generated profile, based on publicly available information

Xu Xu

College of Physics, Jilin University, Changchun, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2020 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
XLXiao-Yi Li
Xiao-Yi Li
JLJing-Bin Lu
Jing-Bin Lu
RZRen-Zhou Zheng
Ren-Zhou Zheng
YWYu Wang
Yu Wang
XXXu Xu
Xu Xu
RHRui He
Rui He

19 January 2021 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
LZLong Zhao
Long Zhao
XXXu Xu
Xu Xu
JLJing-Bin Lu
Jing-Bin Lu
YGYa-Lin Gong
Ya-Lin Gong
QSQing-Feng Song
Qing-Feng Song
YLYan-Feng Li
Yan-Feng Li

1 December 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
XXXu Xu
Xu Xu
JLJing-Bin Lu
Jing-Bin Lu
YCYi Chang
Yi Chang
WTWanyue Tang
Wanyue Tang
YSYuanming Sun
Yuanming Sun
YWYu Wang
Yu Wang

10 February 2023 in Journal of Radiological Protection
Verified
Journal Article
Closed access
XXXu Xu
Xu Xu
ZXZhang Xiaomin
Zhang Xiaomin
NJNing Jing
Ning Jing
XXXie Xiangdong
Xie Xiangdong
YYYuan Yong
Yuan Yong
The neutron dose resulting from external irradiation can be evaluated by measuring the counts of characteristic γ rays produced by 24Na in the human body. The detection geometry with the highest detection efficiency for measuring the whole-body 24Na activity has not been studied. In this work, the MCNP code is used to calculate the spatial distribution of 24Na in the human body irradiated by neutrons with different energies in different irradiation geometries. The fluence distribution of 24Na characteristic γ rays on the body surface is calculated. The counts of 24Na characteristic γ rays induced by monochromatic neutron irradiation are simulated to fit the scenarios of neutron irradiation by a continuous energy spectrum neutron. When the spontaneous neutrons from 252Cf with 1Gy dose irradiate the human body, (3.63–4.35) × 1010 24Na atoms are produced. The lower detection limit for the neutron absorption dose is reduced from ∼100 to less than 1 mGy when the radiation detector is placed over the back of the human body close to the liver. The relative error between the measured counts of 24Na characteristic γ rays caused by 252Cf neutron irradiation and the counts fitted by monochromatic neutron irradiation data is less than 5.7%. The neutron dose received from a continuous energy spectrum neutron can be acquired quickly and accurately by weighted summing of the data for monochromatic neutron irradiations calculated in this paper, which is more convenient and practical than the previous method.

22 February 2023 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
XXXu Xu
Xu Xu
XZXiao-Min Zhang
Xiao-Min Zhang
JNJing Ning
Jing Ning
YYYong Yuan
Yong Yuan
XXXiang-Dong Xie
Xiang-Dong Xie

1 May 2025 in Health Physics
Verified
Journal Article
Closed access
XXXu Xu
Xu Xu
YYYong Yuan
Yong Yuan
XZXiao-Min Zhang
Xiao-Min Zhang
When human body is irradiated by neutrons, the adipose content has a significant impact on the neutron dose and induced 24Na activity. To investigate the effect of human adipose content on the conversion coefficients from 24Na activity to neutron dose, five male adult reference computational phantoms with weights ranging from 73.5 kg to 136.5 kg were used. The Monte Carlo N-particle (MCNP) code was used to calculate the neutron absorbed dose and the yield of induced 24Na in the phantoms irradiated by 252Cf neutrons and monoenergetic neutrons. The results showed that the difference in the conversion coefficients from 24Na activity to neutron absorbed dose among the five phantoms irradiated by 252Cf neutrons with anterior posterior (AP) geometry was ≤23.30%, and this difference was attributed mainly to the neutron absorbed dose, which increases with increasing adipose content. Considering the self-absorption of gamma rays in the human body, the counts of 24Na characteristic gamma rays measured directly by the radiation detector outside of the body have no significant trend varying with adipose content, and the difference in the conversion coefficients from the measured counts to neutron dose among the five phantoms irradiated by 252Cf neutrons with AP geometry was ≤5.25%.