3 February 2020 in Nuclear Science and Techniques
19 January 2021 in Nuclear Science and Techniques
1 December 2021 in Applied Radiation and Isotopes
10 February 2023 in Journal of Radiological Protection
The neutron dose resulting from external irradiation can be evaluated by measuring the counts of characteristic γ rays produced by 24Na in the human body. The detection geometry with the highest detection efficiency for measuring the whole-body 24Na activity has not been studied. In this work, the MCNP code is used to calculate the spatial distribution of 24Na in the human body irradiated by neutrons with different energies in different irradiation geometries. The fluence distribution of 24Na characteristic γ rays on the body surface is calculated. The counts of 24Na characteristic γ rays induced by monochromatic neutron irradiation are simulated to fit the scenarios of neutron irradiation by a continuous energy spectrum neutron. When the spontaneous neutrons from 252Cf with 1Gy dose irradiate the human body, (3.63–4.35) × 1010 24Na atoms are produced. The lower detection limit for the neutron absorption dose is reduced from ∼100 to less than 1 mGy when the radiation detector is placed over the back of the human body close to the liver. The relative error between the measured counts of 24Na characteristic γ rays caused by 252Cf neutron irradiation and the counts fitted by monochromatic neutron irradiation data is less than 5.7%. The neutron dose received from a continuous energy spectrum neutron can be acquired quickly and accurately by weighted summing of the data for monochromatic neutron irradiations calculated in this paper, which is more convenient and practical than the previous method.
22 February 2023 in Applied Radiation and Isotopes
1 May 2025 in Health Physics
When human body is irradiated by neutrons, the adipose content has a significant impact on the neutron dose and induced 24Na activity. To investigate the effect of human adipose content on the conversion coefficients from 24Na activity to neutron dose, five male adult reference computational phantoms with weights ranging from 73.5 kg to 136.5 kg were used. The Monte Carlo N-particle (MCNP) code was used to calculate the neutron absorbed dose and the yield of induced 24Na in the phantoms irradiated by 252Cf neutrons and monoenergetic neutrons. The results showed that the difference in the conversion coefficients from 24Na activity to neutron absorbed dose among the five phantoms irradiated by 252Cf neutrons with anterior posterior (AP) geometry was ≤23.30%, and this difference was attributed mainly to the neutron absorbed dose, which increases with increasing adipose content. Considering the self-absorption of gamma rays in the human body, the counts of 24Na characteristic gamma rays measured directly by the radiation detector outside of the body have no significant trend varying with adipose content, and the difference in the conversion coefficients from the measured counts to neutron dose among the five phantoms irradiated by 252Cf neutrons with AP geometry was ≤5.25%.